Werner Lienhart

Prof. Dr. Werner Lienhart

Graz University of Technology
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 September 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Christoph Martin MonsbergerChristoph Martin Monsberger
Christoph Martin Monsberger
Werner LienhartWerner Lienhart
Werner Lienhart
Civil structural health monitoring (CSHM) has become significantly more important within the last decades due to rapidly growing construction volume worldwide as well as aging infrastructure and longer service lifetimes of the structures. The utilization of distributed fiber optic sensing (DFOS) allows the assessment of strain and temperature distributions continuously along the installed sensing fiber and is widely used for testing of concrete structures to detect and quantify local deficiencies like cracks. Relations to the curvature and bending behavior are however mostly excluded. This paper presents a comprehensive study of different approaches for distributed fiber optic shape sensing of concrete structures. Different DFOS sensors and installation techniques were tested within load tests of concrete beams as well as real-scale tunnel lining segments, where the installations were interrogated using fully-distributed sensing units as well as by fiber Bragg grating interrogators. The results point out significant deviations between the capabilities of the different sensing systems, but demonstrate that DFOS can enable highly reliable shape sensing of concrete structures, if the system is appropriately designed depending on the CSHM application.

27 January 2021 in Journal of Civil Structural Health Monitoring
Verified
Journal Article
Open access
PDF file
Christoph Martin MonsbergerChristoph Martin Monsberger
Christoph Martin Monsberger
Werner LienhartWerner Lienhart
Werner Lienhart
Deformation monitoring and structural reliability assessment are key components in modern conventional tunneling. The state-of-the-art monitoring design is usually based on displacement measurements of geodetic targets using total stations paired with pointwise geotechnical sensors inside the tunnel lining. In recent years, distributed fiber optic sensing (DFOS) has become more popular in tunneling applications. DFOS measurements basically deliver internal strain and temperature distributions, but no direct relation to the tunnel shape’s behavior. This paper introduces a novel sensing and evaluation concept, which combines DFOS strain measurements and geodetic displacement readings for distributed shape assessment along curved structures, such as tunnel cross-sections. The designed system was implemented into shotcrete tunnel cross-sections as well as shaft linings and enables the determination of displacement profiles with high spatial resolution in the range of centimeters. Evaluations of continuous monitoring campaigns over several weeks as well as epoch-wise measurements performed by different DFOS sensing units in combination with stochastic analysis demonstrate the high potential of the developed approach and its capability to extend traditional monitoring methods in tunneling.

13 February 2017 in Journal of Applied Geodesy
Verified
Journal Article
Closed access
PDF file
Werner LienhartWerner Lienhart
Werner Lienhart
MEMatthias Ehrhart
Matthias Ehrhart
MGMagdalena Grick
Magdalena Grick
Robotic total stations (RTS) are frequently used for the measurement of temperature induced bridge deformations or during load testing of bridges. In experimental setups, total stations have also been used for the measurement of dynamic bridge deformations. However, with standard configurations the measurement rate is not constant and on average an update rate of 7–10Hz can be achieved. This is not sufficient for the vibration monitoring of bridges considering their natural frequencies which are also in the same range. In this paper, we present different approaches to overcome these problems. In the first two approaches we demonstrate how the measurement rate to prisms can be increased to 20Hz to determine vertical deformations of bridges. Critical aspects like the measurement resolution of the automated target tracking and the correct sequence of steering commands are discussed. In another approach we demonstrate how vertical bridge vibrations can be measured using an image assisted total station (IATS) and corresponding processing techniques. The advantage of image-based methods is that structural features of a bridge like bolts can be used as targets. Therefore, no expensive prisms have to be mounted and access to the bridge is not required. All approaches are verified by laboratory investigations and their suitability is proven in a field experiment on a 74m long footbridge. In this field experiment the natural frequencies derived from the total station measurements are compared to the results of accelerometer measurements.

17 March 2022 in Journal of Civil Structural Health Monitoring
Verified
Journal Article
Open access
PDF file
Christoph Martin MonsbergerChristoph Martin Monsberger
Christoph Martin Monsberger
Peter BauerPeter Bauer
Peter Bauer
FBFabian Buchmayer
Fabian Buchmayer
Werner LienhartWerner Lienhart
Werner Lienhart
Structural integrity assessment is essential in modern tunneling to ensure safe construction works. State-of-the-art monitoring approaches like displacement readings of geodetic prisms are often limited in the spatial as well as the temporal measurement resolution, which is why potential safety hazards might be overlooked. This paper introduces a large-scale distributed fiber optic sensing (DFOS) network inside the tunnel lining of a highway tunnel currently under construction in Austria. The tunnel construction site faces challenging geological conditions with loose rock excavation near to the surface with minimal covering. Fiber optic sensing cables were installed along both tunnel tubes to autonomously monitor 13 cross-sections of the primary shotcrete lining, about 220 m of the tunnel in longitudinal direction and 10 cross-sections of the secondary inner lining. Measurements are continuously evaluated and autonomously transferred to the geotechnical engineer on-site for further analysis. While the construction works are ongoing, alerts are additionally sent out automatically, if pre-defined thresholds are exceeded. The paper outcomes demonstrate that the innovative DFOS system immediately responds to structural modifications and, indeed, increases safety at the construction site.

25 February 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Peter BauerPeter Bauer
Peter Bauer
Werner LienhartWerner Lienhart
Werner Lienhart
SJSamuel Jost
Samuel Jost
The usage of VR gear in mixed reality applications demands a high position and orientation accuracy of all devices to achieve a satisfying user experience. This paper investigates the system behaviour of the VR system HTC Vive Pro at a testing facility that is designed for the calibration of highly accurate positioning instruments like geodetic total stations, tilt sensors, geodetic gyroscopes or industrial laser scanners. Although the experiments show a high reproducibility of the position readings within a few millimetres, the VR system has systematic effects with magnitudes of several centimetres. A tilt of about 0.4° of the reference plane with respect to the horizontal plane was detected. Moreover, our results demonstrate that the tracking algorithm faces problems when several lighthouses are used.

27 June 2017 in Journal of Civil Structural Health Monitoring
Verified
Journal Article
Open access
PDF file
Werner LienhartWerner Lienhart
Werner Lienhart
Modern geotechnical monitoring is based on a variety of surface-based and integrated sensors. This article discusses the potential but also the limitations of total stations and laser scanners in monitoring of civil infrastructure and natural phenomena. We report about our experiences gained in long-term monitoring projects and discuss the impact of the setup location, the signal travel path, and the target. Although modern instruments are capable of measurements with accuracies of a few millimetres or better, neglecting error sources like temperature dependence of the tilt sensor, orientation of the used prism, obstructions and reflections of the measurement beam, and atmospheric refraction can easily cause errors of several millimetres or even centimetres.