This paper experimentally studies the effects of fly ash on the diffusion, bonding, and micro-properties of chloride penetration in concrete in a water soaking environment based on the natural diffusion law. Different fly ash replacement ratio of cement in normal concrete was investigated. The effect of fly ash on chloride transportation, diffusion, coefficient, free chloride content, and binding chloride content were quantified, and the concrete porosity and microstructure were also reported through mercury intrusion perimetry and scanning electron microscopy, respectively. It was concluded from the test results that fly ash particles and hydration products (filling and pozzolanic effects) led to the densification of microstructures in concrete. The addition of fly ash greatly reduced the deposition of chloride ions. The chloride ion diffusion coefficient considerably decreased with increasing fly ash replacement, and fly ash benefits the binding of chloride in concrete. Additionally, a new equation is proposed to predict chloride binding capacity based on the test results.
Alkali-activated materials (AAMs) are widely recognized as potential alternatives to ordinary Portland cement (OPC) due to their lower carbon footprint. However, like OPC, AAMs can also generate some durable problems when exposed to aggressive environments and the mechanisms and possible improvements are still not fully clear in existing investigations. Furthermore, the corrosion mechanisms of AAMs are different from OPC due to the discrepant reaction products and pore structures. Thus, this study’s aim is to review the chemical reaction mechanisms, factors, and mitigation methods when AAMs are attacked by carbonation and chloride ions, along with a summative discussion regarding instructive insights to durable problems of AAMs.
1 October 2020 in Construction and Building Materials
An investigation was performed by using carbon fiber-reinforced polymer (CFRP) as the anode material in the impressed current cathodic protection (ICCP) system of steel reinforced concrete structures. The service life and performance of CFRP were investigated in simulated ICCP systems with various configurations. Constant current densities were maintained during the tests. No significant degradation in electrical and mechanical properties was found for CFRP subjected to anodic polarization with the selected applied current densities. The service life of the CFRP-based ICCP system was discussed based on the practical reinforced concrete structure layout.