Claudia Prieto

Dr. Claudia Prieto


Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 August 2012 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
MUMuhammad Usman
Muhammad Usman
DADavid Atkinson
David Atkinson
FOFreddy Odille
Freddy Odille
CKChristoph Kolbitsch
Christoph Kolbitsch
GVGhislain Vaillant
Ghislain Vaillant
CPClaudia Prieto
Claudia Prieto
Compressed sensing (CS) has been demonstrated to accelerate MRI acquisitions by reconstructing sparse images of good quality from highly undersampled data. Motion during MR scans can cause inconsistencies in k‐space data, resulting in strong motion artifacts in the reconstructed images. For CS to be useful in these applications, motion correction techniques need to be combined with the undersampled reconstruction. Recently, joint motion correction and CS approaches have been proposed to partially correct for effects of motion. However, the main limitation of these approaches is that they can only correct for affine deformations. In this work, we propose a novel motion corrected CS framework for free‐breathing dynamic cardiac MRI that incorporates a general motion correction formulation directly into the CS reconstruction. This framework can correct for arbitrary affine or nonrigid motion in the CS reconstructed cardiac images, while simultaneously benefiting from highly accelerated MR acquisition. The application of this approach is demonstrated both in simulations and in vivo data for 2D respiratory self‐gated free‐breathing cardiac CINE MRI, using a golden angle radial acquisition. Results show that this approach allows for the reconstruction of respiratory motion corrected cardiac CINE images with similar quality to breath‐held acquisitions. Magn Reson Med 70:504–516, 2013.

7 June 2011 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
MHMarkus Henningsson
Markus Henningsson
PKPeter Koken
Peter Koken
CSChristian Stehning
Christian Stehning
RRReza Razavi
Reza Razavi
CPClaudia Prieto
Claudia Prieto
RBRene Botnar
Rene Botnar

27 February 2014 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
PDF file
CPClaudia Prieto
Claudia Prieto
MDMariya Doneva
Mariya Doneva
MUMuhammad Usman
Muhammad Usman
MHMarkus Henningsson
Markus Henningsson
GGGerald Greil
Gerald Greil
RBRene Botnar
Rene Botnar
Purpose: To develop an efficient 3D affine respiratory motion compensation framework for Cartesian whole‐heart coronary magnetic resonance angiography (MRA).Materials and Methods: The proposed method achieves 100% scan efficiency by estimating the affine respiratory motion from the data itself and correcting the acquired data in the reconstruction process. For this, a golden‐step Cartesian sampling with spiral profile ordering was performed to enable reconstruction of respiratory resolved images at any breathing position and with different respiratory window size. Affine motion parameters were estimated from image‐based registration of 3D undersampled respiratory resolved images reconstructed with iterative SENSE and motion correction was performed directly in the reconstruction using a multiple‐coils generalized matrix formulation method. This approach was tested on healthy volunteers and compared against a conventional diaphragmatic navigator‐gated acquisition using quantitative and qualitative image quality assessment.Results: The proposed approach achieved 47 ± 12% and 59 ± 6% vessel sharpness for the right (RCA) and left (LAD) coronary arteries, respectively. Also, good quality visual scores of 2.4 ± 0.74 and 2.44 ± 0.86 were observed for the RCA and LAD (scores from 0, no to 4, excellent coronary vessel delineation). A not statically significant difference (P = 0.05) was found between the proposed method and an 8‐mm navigator‐gated and tracked scan, although scan efficiency increased from 61 ± 10% to 100%.Conclusion: We demonstrate the feasibility of a new 3D affine respiratory motion correction technique for Cartesian whole‐heart CMRA that achieves 100% scan efficiency and therefore a predictable acquisition time. This approach yields image quality comparable to that of an 8‐mm navigator‐gated acquisition with lower scan efficiency. Further evaluation of this technique in patients is now warranted to determine its clinical use. J. Magn. Reson. Imaging 2015;41:738–746. © 2014 Wiley Periodicals, Inc.

4 March 2019 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
ABAurelien Bustin
Aurelien Bustin
GCGastão Lima da Cruz
Gastão Lima da Cruz
OJOlivier Jaubert
Olivier Jaubert
KLKarina Lopez
Karina Lopez
RBRene Botnar
Rene Botnar
CPClaudia Prieto
Claudia Prieto
Purpose: To develop a new high‐dimensionality undersampled patch‐based reconstruction (HD‐PROST) for highly accelerated 2D and 3D multi‐contrast MRI.Methods: HD‐PROST jointly reconstructs multi‐contrast MR images by exploiting the highly redundant information, on a local and non‐local scale, and the strong correlation shared between the multiple contrast images. This is achieved by enforcing multi‐dimensional low‐rank in the undersampled images. 2D magnetic resonance fingerprinting (MRF) phantom and in vivo brain acquisitions were performed to evaluate the performance of HD‐PROST for highly accelerated simultaneous T1 and T2 mapping. Additional in vivo experiments for reconstructing multiple undersampled 3D magnetization transfer (MT)‐weighted images were conducted to illustrate the impact of HD‐PROST for high‐resolution multi‐contrast 3D imaging.Results: In the 2D MRF phantom study, HD‐PROST provided accurate and precise estimation of the T1 and T2 values in comparison to gold standard spin echo acquisitions. HD‐PROST achieved good quality maps for the in vivo 2D MRF experiments in comparison to conventional low‐rank inversion reconstruction. T1 and T2 values of white matter and gray matter were in good agreement with those reported in the literature for MRF acquisitions with reduced number of time point images (500 time point images, ~2.5 s scan time). For in vivo MT‐weighted 3D acquisitions (6 different contrasts), HD‐PROST achieved similar image quality than the fully sampled reference image for an undersampling factor of 6.5‐fold.Conclusion: HD‐PROST enables multi‐contrast 2D and 3D MR images in a short acquisition time without compromising image quality. Ultimately, this technique may increase the potential of conventional parameter mapping.

25 May 2016 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
GCGastão Cruz
Gastão Cruz
DADavid Atkinson
David Atkinson
MHMarkus Henningsson
Markus Henningsson
RBRene Botnar
Rene Botnar
CPClaudia Prieto
Claudia Prieto
Purpose: To develop a respiratory motion correction framework to accelerate free‐breathing three‐dimensional (3D) whole‐heart coronary lumen and coronary vessel wall MRI.Methods: We developed a 3D flow‐independent approach for vessel wall imaging based on the subtraction of data with and without T2‐preparation prepulses acquired interleaved with image navigators. The proposed method corrects both datasets to the same respiratory position using beat‐to‐beat translation and bin‐to‐bin nonrigid corrections, producing coregistered, motion‐corrected coronary lumen and coronary vessel wall images. The proposed method was studied in 10 healthy subjects and was compared with beat‐to‐beat translational correction (TC) and no motion correction for the left and right coronary arteries. Additionally, the coronary lumen images were compared with a 6‐mm diaphragmatic navigator gated and tracked scan.Results: No significant differences (P > 0.01) were found between the proposed method and the gated and tracked scan for coronary lumen, despite an average improvement in scan efficiency to 96% from 59%. Significant differences (P < 0.01) were found in right coronary artery vessel wall thickness, right coronary artery vessel wall sharpness, and vessel wall visual score between the proposed method and TC.Conclusion: The feasibility of a highly efficient motion correction framework for simultaneous whole‐heart coronary lumen and vessel wall has been demonstrated. Magn Reson Med 77:1894–1908, 2017. © 2016 International Society for Magnetic Resonance in Medicine

29 July 2018 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
ABAurelien Bustin
Aurelien Bustin
GGGiulia Ginami
Giulia Ginami
GCGastão Cruz
Gastão Cruz
TCTeresa Correia
Teresa Correia
TITevfik F. Ismail
Tevfik F. Ismail
CPClaudia Prieto
Claudia Prieto
Purpose: To enable whole‐heart 3D coronary magnetic resonance angiography (CMRA) with isotropic sub‐millimeter resolution in a clinically feasible scan time by combining respiratory motion correction with highly accelerated variable density sampling in concert with a novel 3D patch‐based undersampled reconstruction (3D‐PROST).Methods: An undersampled variable density spiral‐like Cartesian trajectory was combined with 2D image‐based navigators to achieve 100% respiratory efficiency and predictable scan time. 3D‐PROST reconstruction integrates structural information from 3D patch neighborhoods through sparse representation, thereby exploiting the redundancy of the 3D anatomy of the coronary arteries in an efficient low‐rank formulation. The proposed framework was evaluated in a static resolution phantom and in 10 healthy subjects with isotropic resolutions of 1.2 mm3 and 0.9 mm3 and undersampling factors of ×5 and ×9. 3D‐PROST was compared against fully sampled (1.2 mm3 only), conventional parallel imaging, and compressed sensing reconstructions.Results: Phantom and in vivo (1.2 mm3) reconstructions were in excellent agreement with the reference fully sampled image. In vivo average acquisition times (min:s) were 7:57 ± 1:18 (×5) and 4:35 ± 0:44 (×9) for 0.9 mm3 resolution. Sub‐millimeter 3D‐PROST resulted in excellent depiction of the left and right coronary arteries including small branch vessels, leading to further improvements in vessel sharpness and visible vessel length in comparison with conventional reconstruction techniques. Image quality rated by 2 experts demonstrated that 3D‐PROST provides good image quality and is robust even at high acceleration factors.Conclusion: The proposed approach enables free‐breathing whole‐heart 3D CMRA with isotropic sub‐millimeter resolution in <5 min and achieves improved coronary artery visualization in a short and predictable scan time.