Aleksandr Nikolaev

Dr. Aleksandr Nikolaev


Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2015
Verified
Conference Paper
Closed access
Aleksandr A. NikolaevAleksandr A. Nikolaev
Aleksandr A. Nikolaev
PTP.G. Tulupov
P.G. Tulupov
AAA.V. Anufriev
A.V. Anufriev
The article deals with the feasibility assessment of electrical mode control of an electric arc furnace (EAF) using data about higher harmonics of currents and arc voltages. Field re-search was carried out at the operating EAF-180 (150 MVA) of the OJSC “MMK” (Russia, Magnitogorsk) to show the relation-ship between the level of harmonic component of arc current and technological stages of the heat. It was proved that data about higher harmonics of current correlates with heat stages better than electric power consumption, which at present is a common parameter used in most control systems. Diagnostics of heat stages using higher harmonics of arc currents was used with the diagnostics of heat stages using piezoelectric accelerometers installed at the furnace shell. The results of the experiments correlate well with each other. Mathematical model of the EAF electrical circuit was used to study the influence of the main parameters of an electric arc on the levels of higher harmonics of currents and arc volt-ages, and graphs reflecting these relationships were developed. The research group offered an alternative way of changing EAF electrical modes based on the data about higher harmonics of arc voltages.

1 April 2014 in Steel in Translation
Verified
Journal Article
Closed access
PDF file
Aleksandr A. NikolaevAleksandr A. Nikolaev
Aleksandr A. Nikolaev
GKG. P. Kornilov
G. P. Kornilov
AAA. V. Anufriev
A. V. Anufriev
SPS. V. Pekhterev
S. V. Pekhterev
EPE. V. Povelitsa
E. V. Povelitsa
Requirements on the systems controlling the electrical conditions of superpowerful arc furnaces in steel smelting are outlined. The basic principles for electrical optimization at different phases of...

1 December 2016 in Vestnik of Nosov Magnitogorsk State Technical University
Verified
Journal Article
Closed access
NUNosov Magnitogorsk State Technical University
Nosov Magnitogorsk State Technical University
Aleksandr A. NikolaevAleksandr A. Nikolaev
Aleksandr A. Nikolaev
GKGennady P. Kornilov
Gennady P. Kornilov
TKTimur R. Khramshin
Timur R. Khramshin
GNGennady Nikiforov
Gennady Nikiforov
FMFaina F. Mutallapova
Faina F. Mutallapova

27 December 2022 in Energies
Verified
Journal Article
Open access
PDF file
Aleksandr A. NikolaevAleksandr A. Nikolaev
Aleksandr A. Nikolaev
Alexandr S. MaklakovAlexandr S. Maklakov
Alexandr S. Maklakov
MBMikhail Bulanov
Mikhail Bulanov
IGIldar Gilemov
Ildar Gilemov
ADAleksandr Denisevich
Aleksandr Denisevich
MAMaksim Afanasev
Maksim Afanasev
Today, electric drive systems based on frequency converters with active front-end rectifiers (FC-AFEs) are widespread across industries. In the course of the upgrade of production facilities, such systems replace the conventional converters with thyristor- and diode-based rectifiers. FC-AFEs have the following advantages: the capacity to regenerate the power to the grid and the capacity to operate at the set power factor. The manufacturers of FC-AFEs also claim that their products have the best electromagnetic compatibility (EMC) with the power grid. The best EMC shall be achieved via a multilevel FC-AFE topology and specialized pulse-width modulation (PWM) algorithms for AFE rectifiers. However, the experience of operating mid-voltage high-power electric drives with an FC-AFE in 6–35 kV factory distribution grids with non-linear frequency response due to resonant phenomena refutes the claims of the FC-AFE manufacturers. Resonant phenomena in 6–35 kV grids are caused by the interaction of the inductance of grid components (transformers, reactors) and the capacitance of output cable lines. If the resonance frequency at a sufficient amplitude corresponds to the harmonic frequency of the current consumed by the FC-AFE, the distribution grid will feature high-frequency voltage distortions. This may lead to failures in voltage quality-sensitive electrical consumers. This problem recurred at various metallurgical companies. The purpose of this research is to make a comprehensive overview of the EMC problems during the operation of FC-AFEs at active production facilities, as well as the analysis of the technical solutions aimed at the improvement of the EMC of high-power FC-AFEs with the power grid.

18 August 2016
Verified
Conference Paper
Closed access
Aleksandr A. NikolaevAleksandr A. Nikolaev
Aleksandr A. Nikolaev
PTP. G. Tulupov
P. G. Tulupov
The article is concerned with the method, which makes it possible to determine optimal values of phase balancing coefficients for steel-making electric arc furnaces. Application of this method will contribute to setting electrode positioning control system in accordance with the design features of the furnace, thus resulting in improving the total energy efficiency of the electrotechnical complex. The electric arc furnace EAF-120 equipped with the control system of electrical modes Hireg Plus (Danieli, Italy) was chosen as the subject of the research work.

1 January 2016
Verified
Conference Paper
Closed access
Aleksandr A. NikolaevAleksandr A. Nikolaev
Aleksandr A. Nikolaev
PTP. G. Tulupov
P. G. Tulupov
GAG. V. Astashova
G. V. Astashova
The article presents the comparative analysis of electrode control systems of electric arc furnaces and ladle furnaces illustrated by example of ARCOS (Siemens VAI, Primetals Technologies), HIREG (Danieli), EMPERE (Amec Spie) and DECTEQ (Ferrotron). The functional scheme for the following systems presented offers the main algorithms of electrode regulating. Main advantages and disadvantages are mentioned below. Besides, in the frames of our study, the authors present description of the Russian system of electric mode control ASEMC RADUGA NPA LF having a number of advantages in comparison to foreign models.