Marianne Schmid Daners

Dr. Marianne Schmid Daners

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 May 2014 in Journal of The Royal Society Interface
Verified
Journal Article
Open access
PDF file
BSBercan Siyahhan
Bercan Siyahhan
VKVerena Knobloch
Verena Knobloch
DZDiane de Zélicourt
Diane de Zélicourt
MAMahdi Asgari
Mahdi Asgari
MDMarianne Schmid Daners
Marianne Schmid Daners
VKVartan Kurtcuoglu
Vartan Kurtcuoglu
While there is growing experimental evidence that cerebrospinal fluid (CSF) flow induced by the beating of ependymal cilia is an important factor for neuronal guidance, the respective contribution of vascular pulsation-driven macroscale oscillatory CSF flow remains unclear. This work uses computational fluid dynamics to elucidate the interplay between macroscale and cilia-induced CSF flows and their relative impact on near-wall dynamics. Physiological macroscale CSF dynamics are simulated in the ventricular space using subject-specific anatomy, wall motion and choroid plexus pulsations derived from magnetic resonance imaging. Near-wall flow is quantified in two subdomains selected from the right lateral ventricle, for which dynamic boundary conditions are extracted from the macroscale simulations. When cilia are neglected, CSF pulsation leads to periodic flow reversals along the ventricular surface, resulting in close to zero time-averaged force on the ventricle wall. The cilia promote more aligned wall shear stresses that are on average two orders of magnitude larger compared with those produced by macroscopic pulsatile flow. These findings indicate that CSF flow-mediated neuronal guidance is likely to be dominated by the action of the ependymal cilia in the lateral ventricles, whereas CSF dynamics in the centre regions of the ventricles is driven predominantly by wall motion and choroid plexus pulsation.

21 August 2018 in Artificial Organs
Verified
Journal Article
Closed access
PDF file
LWLena Wiegmann
Lena Wiegmann
BTBente Thamsen
Bente Thamsen
DZDiane de Zélicourt
Diane de Zélicourt
Marcus GraneggerMarcus Granegger
Marcus Granegger
SBStefan Boës
Stefan Boës
VKVartan Kurtcuoglu
Vartan Kurtcuoglu

20 February 2020 in Frontiers in Physiology
Verified
Journal Article
Open access
PDF file
DRDavid Renggli
David Renggli
CGChristina Graf
Christina Graf
NTNikolaos Tachatos
Nikolaos Tachatos
NSNavrag B Singh
Navrag B Singh
MMMirko Meboldt
Mirko Meboldt
MDMarianne Schmid Daners
Marianne Schmid Daners
Background: Walking patterns can provide important indications of a person’s health status and be beneficial in the early diagnosis of individuals with a potential walking disorder. For appropriate gait analysis, it is critical that natural functional walking characteristics are captured, rather than those experienced in artificial or observed settings. To better understand the extent to which setting influences gait patterns, and particularly whether observation plays a varying role on subjects of different ages, the current study investigates to what extent people walk differently in lab versus real-world environments and whether age dependencies exist. Methods: The walking patterns of 20 young and 20 elderly healthy subjects were recorded with five wearable inertial measurement units (ZurichMOVE sensors) attached to both ankles, both wrists and the chest. An automated detection process based on dynamic time warping was developed to efficiently identify the relevant sequences. From the ZurichMOVE recordings, 15 spatio-temporal gait parameters were extracted, analyzed and compared between motion patterns captured in a controlled lab environment (10 m walking test) and the non-controlled ecologically valid real-world environment (72 h recording) in both groups. Results: Several parameters (Cluster A) showed significant differences between the two environments for both groups, including an increased outward foot rotation, step width, number of steps per 180° turn, stance to swing ratio, and cycle time deviation in the real-world. A number of parameters (Cluster B) showed only significant differences between the two environments for elderly subjects, including a decreased gait velocity (p = 0.0072), decreased cadence (p = 0.0051) and increased cycle time (p = 0.0051) in real-world settings. Importantly, the real-world environment increased the differences in several parameters between the young and elderly groups. Conclusion: Elderly test subjects walked differently in controlled lab settings compared to their real-world environments, which indicates the need to better understand natural walking patterns under ecologically valid conditions before clinically relevant conclusions can be drawn on a subject’s functional status. Moreover, the greater inter-group differences in real-world environments seem promising regarding the sensitive identification of subjects with indications of a walking disorder.

10 July 2017 in Artificial Organs
Verified
Journal Article
Closed access
PDF file
NCNicholas H. Cohrs
Nicholas H. Cohrs
APAnastasios Petrou
Anastasios Petrou
MLMichael Loepfe
Michael Loepfe
MYMaria Yliruka
Maria Yliruka
CSChristoph M. Schumacher
Christoph M. Schumacher
WSWendelin J. Stark
Wendelin J. Stark

27 November 2012 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
GOGregor Ochsner
Gregor Ochsner
RARaffael Amacher
Raffael Amacher
AAAlois Amstutz
Alois Amstutz
APAndre Plass
Andre Plass
MDMarianne Schmid Daners
Marianne Schmid Daners
LGLino Guzzella
Lino Guzzella
This paper presents a novel mock circulation for the evaluation of ventricular assist devices (VADs), which is based on a hardware-in-the-loop concept. A numerical model of the human blood circulation runs in real time and computes instantaneous pressure, volume, and flow rate values. The VAD to be tested is connected to a numerical-hydraulic interface, which allows the interaction between the VAD and the numerical model of the circulation. The numerical-hydraulic interface consists of two pressure-controlled reservoirs, which apply the computed pressure values from the model to the VAD, and a flow probe to feed the resulting VAD flow rate back to the model. Experimental results are provided to show the proper interaction between a numerical model of the circulation and a mixed-flow blood pump.

30 May 2012 in PLOS ONE
Verified
Journal Article
Open access
PDF file
MDMarianne Schmid Daners
Marianne Schmid Daners
VKVerena Knobloch
Verena Knobloch
MSMichaela Soellinger
Michaela Soellinger
PBPeter Boesiger
Peter Boesiger
BSBurkhardt Seifert
Burkhardt Seifert
VKVartan Kurtcuoglu
Vartan Kurtcuoglu
The objective of this work is to quantify age-related differences in the characteristics and coupling of cerebral arterial inflow and cerebrospinal fluid (CSF) dynamics. To this end, 3T phase-contrast magnetic resonance imaging blood and CSF flow data of eleven young ( years) and eleven elderly subjects ( years) with a comparable sex-ratio were acquired. Flow waveforms and their frequency composition, transfer functions from blood to CSF flows and cross-correlations were analyzed. The magnitudes of the frequency components of CSF flow in the aqueduct differ significantly between the two age groups, as do the frequency components of the cervical spinal CSF and the arterial flows. The males' aqueductal CSF stroke volumes and average flow rates are significantly higher than those of the females. Transfer functions and cross-correlations between arterial blood and CSF flow reveal significant age-dependence of phase-shift between these, as do the waveforms of arterial blood, as well as cervical-spinal and aqueductal CSF flows. These findings accentuate the need for age- and sex-matched control groups for the evaluation of cerebral pathologies such as hydrocephalus.