Marcus Granegger

Dr. Marcus Granegger

Department of Cardiac Surgery, Pediatric Heart Center Vienna, Medical University of Vienna, Vienna, Austria

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 August 2018 in Artificial Organs
Verified
Journal Article
Closed access
PDF file
LWLena Wiegmann
Lena Wiegmann
BTBente Thamsen
Bente Thamsen
DZDiane de Zélicourt
Diane de Zélicourt
Marcus GraneggerMarcus Granegger
Marcus Granegger
SBStefan Boës
Stefan Boës
VKVartan Kurtcuoglu
Vartan Kurtcuoglu

6 August 2012 in Artificial Organs
Verified
Journal Article
Closed access
PDF file
Marcus GraneggerMarcus Granegger
Marcus Granegger
FMFrancesco Moscato
Francesco Moscato
FCFernando Casas
Fernando Casas
GWGeorg Wieselthaler
Georg Wieselthaler
HSHeinrich Schima
Heinrich Schima

18 October 2018 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
SBStefan Boës
Stefan Boës
BTBente Thamsen
Bente Thamsen
MHMattia Haas
Mattia Haas
MDMarianne Schmid Daners
Marianne Schmid Daners
MMMirko Meboldt
Mirko Meboldt
Marcus GraneggerMarcus Granegger
Marcus Granegger
Objective: The hydraulic properties of implantable rotary blood pumps (RBPs) determine their interaction with the cardiovascular system. A systematic comparison in this regard has not yet been performed for different clinically used RBPs. Aim of this study was to describe the hydraulic characteristics of four RBPs with a universal mathematical model and to compare their behavior under clinical operating conditions. Methods: First, static and dynamic pump properties of four RBPs (HVAD, Heartmate II, Heartmate 3 and Incor) including their peripheral components were identified in an in-vitro setup; results were translated into mathematical models based on principles of turbomachinery including the low and backflow region. Second, the four hydraulic models were compared in a numerical simulation of the cardiovascular system for full and partial support conditions. Results: A model structure applicable to each of the investigated RBPs was developed. Deviations between simulated and measured signals for static and dynamic properties were small (2.6 $\pm$ 0.5 mmHg, 0.38 $\pm$ 0.14 L/min, respectively). For a simulated partial support condition, flow pulsatility ranged from 4.1 (Incor) to 9.1 L/min (HVAD). Negative flow rates during diastole were observed in 3 out of 4 pumps. Conclusion: Hydraulic properties differ greatly between the investigated RBPs, with flat characteristics for the HVAD and Heartmate II and steeper curves for the Heartmate 3 and especially the Incor. Significance: Hydraulic characteristics of implantable RBPs are particularly important at lower pump flow rates if backflow is to be avoided. For further research we provide dynamic hydraulic models of the four RBPs including their periphery.

1 April 2020 in The Journal of Thoracic and Cardiovascular Surgery
Verified
Journal Article
Closed access
Marcus GraneggerMarcus Granegger
Marcus Granegger
BTBente Thamsen
Bente Thamsen
TSThomas Schlöglhofer
Thomas Schlöglhofer
SLSelina Lach
Selina Lach
AEAndreas Escher
Andreas Escher
DZDaniel Zimpfer
Daniel Zimpfer

15 October 2020 in ASAIO Journal
Verified
Journal Article
Closed access
ABAndrea Boraschi
Andrea Boraschi
SBSilvia Bozzi
Silvia Bozzi
BTBente Thamsen
Bente Thamsen
Marcus GraneggerMarcus Granegger
Marcus Granegger
LWLena Wiegmann
Lena Wiegmann
FCFilippo Consolo
Filippo Consolo
Contemporary centrifugal continuous-flow left ventricular assist devices (LVADs) incorporate dynamic speed modulation algorithms. Hemocompatibility of these periodic unsteady pump operating conditions has been only partially explored. We evaluated whether speed modulation induces flow alterations associated with detrimental prothrombotic effects. For this aim, we evaluated the thrombogenic profile of the HeartWare ventricular assist device (HVAD) Lavare Cycle (LC) and HeartMate3 (HM3) artificial pulse (AP) via comprehensive numerical evaluation of (i) pump washout, (ii) stagnation zones, (iii) shear stress regimens, and (iv) modeling of platelet activation status via the platelet activity state (PAS) model. Data were compared between different simulated operating scenarios, including: (i) constant rotational speed and pump pressure head, used as reference; (ii) unsteady pump pressure head as induced by cardiac pulsatility; and (iii) unsteady rotor speed modulation of the LC (HVAD) and AP (HM3). Our results show that pump washout did not improve across the different simulated scenarios in neither the HVAD nor the HM3. The LC reduced but did not eliminate flow stagnation (–57%) and did not impact metrics of HVAD platelet activation (median PAS: +0.4%). The AP reduced HM3 flow stagnation by up to 91% but increased prothrombotic shear stress and simulated platelet activation (median PAS: +124%). Our study advances understanding of the pathogenesis of LVAD thrombosis, suggesting mechanistic implications of rotor speed modulation. Our data provide rationale criteria for the future design optimization of next generation LVADs to further reduce hemocompatibility-related adverse events.

1 August 2013 in Artificial Organs
Verified
Journal Article
Closed access
PDF file
FMFrancesco Moscato
Francesco Moscato
Marcus GraneggerMarcus Granegger
Marcus Granegger
MEMichael Edelmayer
Michael Edelmayer
DZDaniel Zimpfer
Daniel Zimpfer
HSHeinrich Schima
Heinrich Schima