Beshoy Maher Hakeem

Dr. Beshoy Maher Hakeem


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 January 2024 in Journal of Umm Al-Qura University for Engineering and Architecture
Verified
Journal Article
Open access
PDF file
FHFaek Hassona
Faek Hassona
BHBeshoy Maher Hakeem
Beshoy Maher Hakeem
The definition of soil stabilization is a method to enhance the engineering properties. Polyurethane grout is one of the least expensive methods and can be used in construction. Polyurethane injection resin systems for crack injection, slab lifting, soil stabilization, leak sealing, and structural crack repair have been used for the last two decades. Polyurethane foam hasn't been used or understood as a loaded structural element in soils like as embedded piles. In this piece of work, a trial was made to numerically study the behavior of polyurethane foam when used as piles embedded in the clay and sand soils. Plaxis 3D software was adopted to carry out this study. Polyurethane piles of varying diameters and lengths were modelled as embedments in the clay and sand soil, and then incremental loads were applied. Moreover, the study involved the behavior of polyurethane piles when the clay strength was increased. The results indicated that embedded pile resistance to loading increased with the increase in length and pile diameter. When the loading results of polyurethane foam embedded in loose sand are compared with the loading results of piles in soft clay, the ultimate capacity of piles in loose sand, was much higher than that in soft clay. The results also indicated that the polyurethane pile load-carrying capacity increased when L/D ratio decreased for both soft and stiff clay. In this study concrete piles in clay and sand soil were modelled to examine the percentage of loading capacity of concrete piles to that of polyurethane piles for clay and sand soil.


1 January 2022 in Journal of Advanced Engineering Trends
Verified
Journal Article
Closed access
PDF file
AEAbdelrahman Elsherief
Abdelrahman Elsherief
FHFayek Hassona
Fayek Hassona
BHBeshoy Maher Hakeem
Beshoy Maher Hakeem
ABAhmed Moussa Abu Bakr
Ahmed Moussa Abu Bakr
In the general design of piled raft foundations, total loads are assumed to be taken by the pile. The contact pressure between raft and the soil is neglected. This may lead to loading piles with larger loads than they should be which could be reduced by sharing it with soil on which the raft is based. In this study, a trial was made to separate the amount of load carried by piles and that carried by soil. This was achieved by elevating raft one meter above ground surface. 3D finite element program PLAXIS 3D was used to simulate this case. In this paper, the effect of different parameters on carrying capacity of the piled raft were taken into consideration, such as pile spacing, pile diameter and raft thickness. Finally, to introduce an economical design for piled raft foundation, the settlement reduction ratio (SRR) and load sharing ratio of piles (αpr) were determined. The numerical results showed that the load carry by soil increases with the increases of pile spacing. In case of elevated piled raft, the load carried by piles was constant, although the pile spacing was increased under the raft thickness and pile diameter are constant. The discussion of results shows that the load carried by soil ranges from 7-14% of the total load, and maximum settlement at the elevated piled raft was higher than the maximum settlement at piled raft rested on soil with different pile spacing.


1 January 2022 in Journal of Advanced Engineering Trends
Verified
Journal Article
Closed access
PDF file
BHBeshoy Maher Hakeem
Beshoy Maher Hakeem
FHFayek Abdel Kader Hassona
Fayek Abdel Kader Hassona
Thermal physical phenomenon of soils and rocks constitutes an important property for the planning of heat foundations and borehole heat exchange systems. To determine soil thermal properties considerable effort has gone into developing techniques in recent years. This paper attempts to simulate the effectiveness of using a soil with higher thermal conductivity compared to normal sand using GeoStudio 2018 Finite Element 2D program. GeoStudio was used to verify a physical laboratory model which was built to investigate the variation in soil temperature related to the proposed ambient temperature conditions [1]. In this research, two different backfilling soils were adopted to carry out this work. The results show excellent agreements between the laboratory model and numerical results. Ground temperature of sand backfill is affected by ambient temperature and reaches a constant value at depths below 1.0 m from ground surface. Limestone powder of higher thermal conductivity reaches a constant value at depths below 0.75 m from ground surface. The results show that using GeoStudio 2018 program to simulate the variation in soil temperature with depth for different types of soil is feasible.

30 May 2024 in Journal of Umm Al-Qura University for Engineering and Architecture
Verified
Journal Article
Open access
PDF file
FHFaek Hassona
Faek Hassona
BHBeshoy Maher Hakeem
Beshoy Maher Hakeem
Polyurethane foam (P.U.) injection resin techniques have been widely used for slab crack repair, soil improvement, and structural crack repair over the past 20 years. In this study, numerical investigations were carried out to enhance the strength of both sand and clay soils via utilizing polyurethane foam as inclusion material. The investigation was conducted using ‘GeoStudio (SLOPE/W) 2D’ software to model 6 m high homogeneous slopes made of soft clay and medium sand with varying slope angles (25°, 30°, 35°) on same soil extended up to 9 m depth and with inclusion of polyurethane foam piles of varying diameter (0.5 m, 0.8 m), length (up to 10 m) and spacing (0.5 m, 1 m, 2 m) in the slope face. The numerical model was verified using experimental test results conducted by Hassona and Abdelnaeem (Physical and mechanical properties of polyurethane foam conditioned sand. MSc, Civil Engineering Department, Faculty of Engineering Minia University). The results revealed that, for slope angle, Ø = 30°, the factor of safety for clay soil increased when using polyurethane piles (diameter, 0.5 m and 10 m length) having spacing of two m, one m, half m, and when used as sheet piles, respectively. The factor of safety for clay soil increased significantly when using polyurethane piles (diameter, 0.8 m, and 10 m length) having spacing the same as before and as sheet piles having width of 0.5 and 0.8 m, respectively. Also, for medium dense sand soil, using polyurethane piles (diameter, 0.5 m and 10 m length) having spacing the same as before, and as sheet piles increased factor of safety much more than that for clay soil. In addition, for medium dense sand soil similar observation were noticed using polyurethane piles (diameter 0.8 m, and 10 m length) having spacing the same as before, and as sheet piles, respectively. In addition, the effects of slope angles also studied.