Abdelrahman Elsherief

Dr. Abdelrahman Elsherief

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2022 in Journal of Advanced Engineering Trends
Verified
Journal Article
Closed access
PDF file
AEAbdelrahman Elsherief
Abdelrahman Elsherief
FHFayek Hassona
Fayek Hassona
BHBeshoy Maher Hakeem
Beshoy Maher Hakeem
ABAhmed Moussa Abu Bakr
Ahmed Moussa Abu Bakr
In the general design of piled raft foundations, total loads are assumed to be taken by the pile. The contact pressure between raft and the soil is neglected. This may lead to loading piles with larger loads than they should be which could be reduced by sharing it with soil on which the raft is based. In this study, a trial was made to separate the amount of load carried by piles and that carried by soil. This was achieved by elevating raft one meter above ground surface. 3D finite element program PLAXIS 3D was used to simulate this case. In this paper, the effect of different parameters on carrying capacity of the piled raft were taken into consideration, such as pile spacing, pile diameter and raft thickness. Finally, to introduce an economical design for piled raft foundation, the settlement reduction ratio (SRR) and load sharing ratio of piles (αpr) were determined. The numerical results showed that the load carry by soil increases with the increases of pile spacing. In case of elevated piled raft, the load carried by piles was constant, although the pile spacing was increased under the raft thickness and pile diameter are constant. The discussion of results shows that the load carried by soil ranges from 7-14% of the total load, and maximum settlement at the elevated piled raft was higher than the maximum settlement at piled raft rested on soil with different pile spacing.

1 July 2025 in International Journal of Applied Energy Systems
Verified
Journal Article
Open access
PDF file
AEAbdelrahman Elsherief
Abdelrahman Elsherief
ِRِaHmed M Reda
ِaHmed M Reda
AEAhmed M Eltohamy
Ahmed M Eltohamy
AHAli Hafez
Ali Hafez
HMHany Madkour
Hany Madkour
SKSafia Mohamed Khodary
Safia Mohamed Khodary
This study investigates the thermal performance of a Horizontal Spiral Ground Heat Exchanger (HSGHE) under varying inlet temperatures in hot climates, with a focus on ground source heat pumps (GSHPs) as a sustainable energy solution. The experimental setup utilized a spiral tube embedded in dry sand placed within a controlled environment. The results indicated that inlet temperature significantly influences heat exchange rates (HER). Higher inlet temperatures initially resulted in higher HER, but these values declined over time due to the diminishing temperature gradient between the circulating fluid and surrounding soil. For an inlet temperature of 50°C, reductions in HER of approximately 40% and 63% were observed at 45°C and 40°C, respectively. After six hours, HER decreased by 58%, 50%, and 36% for 50°C, 45°C, and 40°C, respectively. These findings highlight the long-term impact of inlet temperature on system efficiency, where higher initial HER does not always correlate with sustained high performance.The study also assessed soil thermal dispersion and found that heat dissipation was highly localized. For 50°C, the thermal effect extended up to 0.4 meters, while at 45°C, it diminished to 0.3 meters, and at 40°C, the effect was minimal beyond a short distance. Based on these results, an optimal spacing of 0.8 meters between exchangers is recommended to minimize thermal interference and maximize system efficiency. These findings underscore the importance of temperature gradients and operational parameters in optimizing ground heat exchanger performance in hot climates.

1 July 2025 in International Journal of Applied Energy Systems
Verified
Journal Article
Open access
PDF file
AEAbdelrahman Elsherief
Abdelrahman Elsherief
ِRِaHmed M Reda
ِaHmed M Reda
AEAhmed M Eltohamy
Ahmed M Eltohamy
AHAli Hafez
Ali Hafez
HMHany Madkour
Hany Madkour
SKSafia Mohamed Khodary
Safia Mohamed Khodary
Ground heat exchangers (GHE) are extensively utilized in geothermal heating and cooling systems due to their efficiency and sustainability. This research presents an experimental study on the effect of flow rate on the performance of horizontal ground heat exchangers (HGHE) in sand soil. The study investigates how varying flow rates impact heat exchange efficiency, soil temperature distribution, and thermal performance during hot climates. A laboratory setup was developed to simulate real-world conditions, incorporating a spiral coil heat exchanger buried in sand soil. Experiments were conducted at different flow rates (5 L/min, 6 L/min, and 7 L/min), while monitoring temperature variations in both the soil and circulating fluid. The results indicate that increasing the flow rate enhances convective heat transfer, leading to a 31.8% improvement in heat exchange rate (HER) when increasing from 5 L/min to 7 L/min. However, the benefits diminish over time, with HER decreasing by approximately 55% within the first three hours as thermal equilibrium is approached.In terms of soil temperature distribution, the study found that heat dissipation in the horizontal direction becomes negligible beyond 0.4 meters, while in the vertical direction, temperature influence fades beyond 0.4 meters. At lower flow rates, soil temperature gain increased by up to 38% compared to higher flow rates, due to prolonged heat retention. This study focuses the importance of optimizing flow rates to balance energy efficiency and thermal performance in ground heat exchangers