An improved analysis for single-particle imaging (SPI) experiments, using the limited data, is presented here. Results are based on a study of bacteriophage PR772 performed at the Atomic, Molecular and Optical Science instrument at the Linac Coherent Light Source as part of the SPI initiative. Existing methods were modified to cope with the shortcomings of the experimental data: inaccessibility of information from half of the detector and a small fraction of single hits. The general SPI analysis workflow was upgraded with the expectation-maximization based classification of diffraction patterns and mode decomposition on the final virus-structure determination step. The presented processing pipeline allowed us to determine the 3D structure of bacteriophage PR772 without symmetry constraints with a spatial resolution of 6.9 nm. The obtained resolution was limited by the scattering intensity during the experiment and the relatively small number of single hits.
Satellite research methods are frequently used in observations of water bodies. One of the most important problems in satellite observations is the presence of missing data due to internal malfunction of satellite sensors and poor atmospheric conditions. We proceeded on the assumption that the use of data recovery methods based on spatial relationships in data can increase the recovery accuracy. In this paper, we present a method for missing data reconstruction from remote sensors. We refer our method to as Tensor Interpolating Empirical Orthogonal Functions (TIEOF). The method relies on the two-dimensional nature of sensor images and organizes the data into three-dimensional tensors. We use high-order tensor decomposition to interpolate missing data on chlorophyll a concentration in lake Baikal (Russia, Siberia). Using MODIS and SeaWiFS satellite data of lake Baikal we show that the observed improvement of TIEOF was 69% on average compared to the current state-of-the-art DINEOF algorithm measured in various preprocessing data scenarios including thresholding and different interpolating schemes.
In this paper we present an approach to the on-the-fly Cryo-EM data acquisition and analysis using High Performance Data Analysis concept. An analysis of bottlenecks in the currently used data processing is presented, and the new iterative scheme for near real time implementation of the Cryo-EM data processing is discussed. The on-the-fly approach is proposed that will considerably reduce the time required for the protein (or other biological objects, e.g. viruses) 3D structure determination and allow eliminating manual interventions in the data processing.