Monica Contino

Dr. Monica Contino


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2012 in The Journal of Thoracic and Cardiovascular Surgery
Verified
Journal Article
Closed access
MLMassimo G. Lemma
Massimo G. Lemma
ECEnrico Coscioni
Enrico Coscioni
FTFrancesco P. Tritto
Francesco P. Tritto
PCPaolo Centofanti
Paolo Centofanti
CFCorrado Fondacone
Corrado Fondacone
MGMichele Genoni
Michele Genoni

1 September 2016 in JACC
Verified
Journal Article
Open access
RVRiccardo Vismara
Riccardo Vismara
GGGuido Gelpi
Guido Gelpi
SPSantosh Prabhu
Santosh Prabhu
PRPaolo Romitelli
Paolo Romitelli
LTLauren G. Troxler
Lauren G. Troxler
CACarlo Antona
Carlo Antona
Although associated with left heart pathologies, functional tricuspid regurgitation (FTR) is often left untreated during left heart surgery. Hence, owing to its degenerative character, reoperation is often needed, encompassing an impressive (25% to 35%) mortality rate. Thus transcatheter approaches to FTR are raising great interest. The authors evaluated the post-treatment effectiveness of the edge-to-edge technique using the percutaneous mitral valve repair device in an ex vivo pulsatile model of FTR. The devices were implanted in 11 porcine hearts simulating FTR. In each heart, single-clip treatments involved grasping leaflet pairs in the medial or commissural position (6 combinations). Two-clip treatments were then performed considering all possible 15 combinations of leaflet pairs and medial/commissural grasping. Cardiac output, mean pulmonary pressure, and mean diastolic valve pressure gradient were evaluated in physiological and simulated pathological conditions (FTR), and post-treatments. Grasping the septal and anterior leaflets allowed for the best post-procedural outcome, ensuring a complete re-establishment of physiological-like hemodynamics. Septal and posterior grasping induced a significant recovery from FTR, although less marked. Conversely, grasping the anterior and posterior leaflets did not reduce FTR, and was detrimental in some specific cases. This experimental work demonstrated that the transcatheter edge-to-edge repair technique is a feasible approach for FTR. The study investigated this approach to develop a selective, specific structural intervention methodology for treating FTR, considering the several biomechanical factors that alter proper functionality of valvular substructures. These results can be used to guide the development of edge-to-edge repair techniques in treatment of FTR.

1 April 2012 in Journal of Biomechanics
Verified
Journal Article
Closed access
ALA.M. Leopaldi
A.M. Leopaldi
RVR. Vismara
R. Vismara
MLM. Lemma
M. Lemma
LVL. Valerio
L. Valerio
MCM. Cervo
M. Cervo
GFG.B. Fiore
G.B. Fiore

26 February 2015 in European Journal of Cardio-Thoracic Surgery
Verified
Journal Article
Closed access
PDF file
MCMonica Contino
Monica Contino
AMAndrea Mangini
Andrea Mangini
MLMassimo Giovanni Lemma
Massimo Giovanni Lemma
CRClaudia Romagnoni
Claudia Romagnoni
PZPietro Zerbi
Pietro Zerbi
CACarlo Antona
Carlo Antona
OBJECTIVES The aim of this study was the analysis of the geometrical relationships between the different structures constituting the aortic root, with particular attention to interleaflet triangles, haemodynamic ventriculo-arterial junction and functional aortic annulus in normal subjects. METHODS Sixteen formol-fixed human hearts with normal aortic roots were studied. The aortic root was isolated, sectioned at the midpoint of the non-coronary sinus, spread apart and photographed by a high-resolution digital camera. After calibration and picture resizing, the software AutoCAD 2004 was used to identify and measure all the elements of the interleaflets triangles and of the aortic root that were objects of our analysis. Multiple comparisons were performed with one-way analysis of variance for continuous data and with Kruskal–Wallis analysis for non-continuous data. Linear regression and Pearson's product correlation were used to correlate root element dimensions when appropriate. Student's t-test was used to compare means for unpaired data. Heron's formula was applied to estimate the functional aortic annular diameters. RESULTS The non coronary–left coronary interleaflets triangles were larger, followed by inter-coronary and right-non-coronary ones. The apical angle is <60° and its standard deviation can be considered an asymmetry index. The sinu-tubular junction was shown to be 10% larger than the virtual basal ring (VBR). The mathematical relationship between the haemodynamic ventriculo-arterial junction and the VBR calculated by linear regression and expressed in terms of the diameter was: haemodynamic ventriculo-arterial junction = 2.29 VBR (diameter) + 47. DISCUSSION Conservative aortic surgery is based on a better understanding of aortic root anatomy and physiology. The relationships among its elements are of paramount importance during aortic valve repair/sparing procedures and they can be useful also in echocardiographic analysis and in computed tomography reconstruction.

1 July 2010 in ASAIO Journal
Verified
Journal Article
Closed access
RVRiccardo Vismara
Riccardo Vismara
GFGianfranco B. Fiore
Gianfranco B. Fiore
AMAndrea Mangini
Andrea Mangini
MCMonica Contino
Monica Contino
MLMassimo Lemma
Massimo Lemma
CACarlo Antona
Carlo Antona
The aortic root functional unit (ARFU) is a complex structure whose functions are strictly dependent on the biomechanical interaction among each of its anatomically defined elements. The classical approach to the in vitro study of aortic hydrodynamics does not take this complexity into account. We propose a novel methodology based on the possibility to house whole natural ARFU samples in a purposely designed pulsatile mock loop, allowing for aortic surgery simulation. To point out the usability and potentialities of the device, the mock loop was tested with untreated porcine ARFU samples and with one ARFU prosthesized with a state-of-the-art bioprosthesis. The sample holder design was proved to allow the clinician to house and treat the ARFU sample in the mock loop with easiness and repeatability. The valve leakage with the prosthesized ARFU was comparable with literature data, and Effective orifice areas were consistent with the constructor's data. In contrast, the recorded pressure drops exceeded the data from the manufacturer and were quite aligned with in vivo postop echo-Doppler data acquired in implant recipients. This result suggests that our apparatus and methodology provide a way to investigate aortic hydrodynamic phenomena that resemble in a close way to those taking place in the final recipients' circulation.

1 December 2010 in European Journal of Vascular and Endovascular Surgery
Verified
Journal Article
Closed access
GGG. Gelpi
G. Gelpi
PVP. Vanelli
P. Vanelli
AMA. Mangini
A. Mangini
PDP. Danna
P. Danna
MCMonica Contino
Monica Contino
CAC. Antona
C. Antona