Sarcomas are associated with a relatively high local recurrence rate of around 30 % in the pelvis. Inadequate surgical margins are the most important reason. However, obtaining adequate margins is particularly difficult in this anatomically demanding region. Recently, three-dimensional (3-D) planning, printed models, and patient-specific instruments (PSI) with cutting blocks have been introduced to improve the precision during surgical tumor resection. This case series illustrates these modern 3-D tools in pelvic tumor surgery. The first consecutive patients with 3-D-planned tumor resection around the pelvis were included in this retrospective study at a University Hospital in 2015. Detailed information about the clinical presentation, imaging techniques, preoperative planning, intraoperative surgical procedures, and postoperative evaluation is provided for each case. The primary outcome was tumor-free resection margins as assessed by a postoperative computed tomography (CT) scan of the specimen. The secondary outcomes were precision of preoperative planning and complications. Four patients with pelvic sarcomas were included in this study. The mean follow-up was 7.8 (range, 6.0–9.0) months. The combined use of preoperative planning with 3-D techniques, 3-D-printed models, and PSI for osteotomies led to higher precision (maximal (max) error of 0.4 centimeters (cm)) than conventional 3-D planning and freehand osteotomies (max error of 2.8 cm). Tumor-free margins were obtained where measurable (n = 3; margins were not assessable in a patient with curettage). Two insufficiency fractures were noted postoperatively. Three-dimensional planning as well as the intraoperative use of 3-D-printed models and PSI are valuable for complex sarcoma resection at the pelvis. Three-dimensionally printed models of the patient anatomy may help visualization and precision. PSI with cutting blocks help perform very precise osteotomies for adequate resection margins.
4 October 2011 in Journal of Bone and Mineral Research
Correct sagittal alignment with a balanced pelvis and spine is crucial in the management of spinal disorders. The pelvic incidence (PI) describes the sagittal pelvic alignment and is position-independent. It has barely been investigated on CT scans. Furthermore, no studies have focused on the association between PI and facet joint (FJ) arthritis and orientation. Therefore, our goal was to clarify the remaining issues about PI in regard to (1) physiologic values, (2) age, (3) gender, (4) lumbar lordosis (LL) and (5) FJ arthritis and orientation using CT scans.
1 July 2013 in Clinical Orthopaedics and Related Research
Reconstruction of the extensor mechanism after resection of the proximal tibia is challenging, and several methods are available. A medial gastrocnemius flap commonly is used, although it may be associated with an extensor lag. This problem also is encountered, although perhaps to a lesser extent, with other techniques for reconstruction of the extensor apparatus. It is not known how such lag develops with time and how it correlates with functional outcome. We therefore (1) assessed patellar height with time, (2) correlated patellar height with function using the Musculoskeletal Tumor Society (MSTS) score, and (3) correlated patellar height with range of motion (ROM) after medial gastrocnemius flap reconstruction. Sixteen patients underwent tumor endoprosthesis implantation and extensor apparatus reconstruction between 1997 and 2009 using a medial gastrocnemius flap after sarcoma resection of the proximal tibia. These patients represented 100% of the population for whom we performed extensor mechanism reconstructions during that time. The minimum followup was 2 years (mean, 5 years; range, 2–11 years). Fourteen patients were alive at the time of this study. We used the Blackburne-Peel Index to follow patellar height radiographically with time. Functional outcomes were assessed retrospectively using the MSTS, and ROM was evaluated through active extensor lag and flexion. Eleven patients had patella alta develop, whereby the maximal patellar height was reached after a mean of 2 years and then stabilized. More normal patellar height was associated with better functional scores, a smaller extensor lag, but less flexion; the mean extensor lag (and flexion) of patients with patella alta was 17° (and 94°) compared with only 4° (and 77°) without. In our patients patella alta evolved during the first 2 postoperative years. Patella alta is associated with extensor lag, greater flexion, and worse MSTS scores. Surgical fixation of the patellar tendon more distally to its anatomic position or strict postoperative bracing may be advisable. Level IV, clinical cohort study. See the Guidelines for Authors for a complete description of levels of evidence.
19 June 2015 in Archives of orthopaedic and trauma surgery