Matthias Haase

Prof. Dr. Matthias Haase

Department of Life Sciences and Facility Management, Zurich University of Applied Sciences, CH-8820 Wädenswil, Switzerland
orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2013 in Applied Energy
Verified
Journal Article
Open access
FGFrancesco Goia
Francesco Goia
Matthias HaaseMatthias Haase
Matthias Haase
MPMarco Perino
Marco Perino
The building enclosure plays a relevant role in the management of the energy flows in buildings and in the exploitation of solar energy at a building scale. An optimized configuration of the façade can contribute to reduce the total energy demand of the building. Traditionally, the search for the optimal façade configuration is obtained by analyzing the heating demand and/or the cooling demand only, while the implication of the façade configuration on artificial lighting energy demand is often not addressed. A comprehensive approach (i.e. including heating, cooling and artificial lighting energy demand) is instead necessary to reduce the total energy need of the building and the optimization of the façade configuration becomes no longer straightforward, because non-linear relationships are often disclosed. The paper presents a methodology and the results of the search for the optimal transparent percentage in a façade module for low energy office buildings. The investigation is carried out in a temperate oceanic climate, on the four main orientations, on three versions of the office building and with different HVAC system's efficiency. The results show that, regardless of the orientations and of the façade area of the building, the optimal configuration is achieved when the transparent percentage is between 35% and 45% of the total façade module area. The highest difference between the optimal configuration and the worst one occurs in the north-exposed façade, while the south-exposed façade is the one that shows the smallest difference between the optimal and the worst configuratio

1 November 2012 in Energy and Buildings
Verified
Journal Article
Closed access
FGFrancesco Goia
Francesco Goia
Marco PerinoMarco Perino
Marco Perino
Matthias HaaseMatthias Haase
Matthias Haase


1 May 2014 in Energy and Buildings
Verified
Journal Article
Closed access
AWAoife Houlihan Wiberg
Aoife Houlihan Wiberg
Laurent GeorgesLaurent Georges
Laurent Georges
TDTor Helge Dokka
Tor Helge Dokka
Matthias HaaseMatthias Haase
Matthias Haase
BTBerit Time
Berit Time
MMMette Maltha
Mette Maltha

1 April 2009 in Energy and Buildings
Verified
Journal Article
Closed access
Matthias HaaseMatthias Haase
Matthias Haase
FSFernando Marques Da Silva
Fernando Marques Da Silva
AAA. Amato
A. Amato

10 October 2014 in Building Research & Information
Verified
Journal Article
Closed access
Laurent GeorgesLaurent Georges
Laurent Georges
Matthias HaaseMatthias Haase
Matthias Haase
AWAoife Houlihan Wiberg
Aoife Houlihan Wiberg
TKTorhildur Kristjansdottir
Torhildur Kristjansdottir
BRBirgit Risholt
Birgit Risholt
The net-zero emissions building (nZEB) performance is investigated for building operation (EO) and embodied emissions in materials (EE) for Norway's cold climate. nZEB concepts for new residential and office buildings are conceived in order to understand the balance and implications between operational and embodied emissions over the building's life. The main drivers for the CO2 equivalent (CO2e) emissions are revealed for both building concepts through a detailed emissions calculation. The influence of the CO2e factor for electricity is emphasized and it is shown to have significant impact on the temporal evolution of the overall CO2e emissions balance. The results show that the criterion for zero emissions in operation is easily reached for both nZEB concepts (independent of the CO2e factor considered). Embodied emissions are significant compared to operational emissions. It was found that an overall emissions balance including both operational and embodied energy is difficult to reach and would be unobtainable in a scenario of low carbon electricity from the grid. In this particular scenario, the net balance of emissions alone is nonetheless not a sufficient performance indicator for nZEB.