Francesco Goia

Francesco Goia

Auto-generated profile, based on publicly available information

Francesco Goia

Department of Architecture and Technology, Norwegian University of Science and Technology NTNU, Alfred Getz vei 3, 7491 Trondheim, Norway

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications


1 November 2018 in Energy and Buildings
Verified
Journal Article
Closed access
Shady AttiaShady Attia
Shady Attia
SBSenem Bilir
Senem Bilir
TSTaha Safy
Taha Safy
CSChristian Struck
Christian Struck
RLRoel Loonen
Roel Loonen
FGFrancesco Goia
Francesco Goia

1 February 2014 in Solar Energy
Verified
Journal Article
Closed access
FGFrancesco Goia
Francesco Goia
Marco PerinoMarco Perino
Marco Perino
Valentina SerraValentina Serra
Valentina Serra

1 May 2013 in Energy and Buildings
Verified
Journal Article
Closed access
FGFrancesco Goia
Francesco Goia
MPMarco Perino
Marco Perino
Valentina SerraValentina Serra
Valentina Serra

1 August 2013 in Applied Energy
Verified
Journal Article
Open access
FGFrancesco Goia
Francesco Goia
Matthias HaaseMatthias Haase
Matthias Haase
MPMarco Perino
Marco Perino
The building enclosure plays a relevant role in the management of the energy flows in buildings and in the exploitation of solar energy at a building scale. An optimized configuration of the façade can contribute to reduce the total energy demand of the building. Traditionally, the search for the optimal façade configuration is obtained by analyzing the heating demand and/or the cooling demand only, while the implication of the façade configuration on artificial lighting energy demand is often not addressed. A comprehensive approach (i.e. including heating, cooling and artificial lighting energy demand) is instead necessary to reduce the total energy need of the building and the optimization of the façade configuration becomes no longer straightforward, because non-linear relationships are often disclosed. The paper presents a methodology and the results of the search for the optimal transparent percentage in a façade module for low energy office buildings. The investigation is carried out in a temperate oceanic climate, on the four main orientations, on three versions of the office building and with different HVAC system's efficiency. The results show that, regardless of the orientations and of the façade area of the building, the optimal configuration is achieved when the transparent percentage is between 35% and 45% of the total façade module area. The highest difference between the optimal configuration and the worst one occurs in the north-exposed façade, while the south-exposed façade is the one that shows the smallest difference between the optimal and the worst configuratio