Frederick Haselton

Dr. Frederick Haselton

orcid

Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 August 2007 in Bioconjugate Chemistry
Verified
Journal Article
Closed access
AJAshwath Jayagopal
Ashwath Jayagopal
PRPatricia K. Russ
Patricia K. Russ
FHFrederick Haselton
Frederick Haselton

16 December 2011 in Langmuir
Verified
Journal Article
Closed access
JTJoshua R. Trantum
Joshua R. Trantum
DWDavid W. Wright
David W. Wright
FHFrederick Haselton
Frederick Haselton

8 November 2013 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
JTJoshua R. Trantum
Joshua R. Trantum
MBMark L. Baglia
Mark L. Baglia
ZEZachary E. Eagleton
Zachary E. Eagleton
RMRaymond L. Mernaugh
Raymond L. Mernaugh
FHFrederick Haselton
Frederick Haselton
Effective point-of-care diagnostics require a biomarker detection strategy that is low-cost and simple-to-use while achieving a clinically relevant limit of detection. Here we report a biosensor that uses secondary flows arising from surface Marangoni stresses in an evaporating drop to concentrate target-mediated particle aggregates in a visually detectable spot. The spot size increases with increasing target concentration within the dynamic range of the assay. The particle deposition patterns are visually detectable and easily measured with simple optical techniques. We use optical coherence tomography to characterize the effect of cross-sectional flow fields on the motion of particles in the presence and absence of target (aggregated and non-aggregated particles, respectively). We show that choice of substrate material and the presence of salts and glycerol in solution promote the Marangoni-induced flows that are necessary to produce signal in the proposed design. These evaporation-driven flows generate signal in the assay on a PDMS substrate but not substrates with greater thermal conductivity like indium tin oxide-coated glass. In this proof-of-concept design we use the M13K07 bacteriophage as a model target and 1 μm-diameter particles surface functionalized with anti-M13 monoclonal antibodies. Using standard microscopy-based techniques to measure the final spot size, the assay has a calculated limit-of-detection of approximately 100 fM. Approximately 80% of the maximum signal is generated within 10 minutes of depositing a 1 μL drop of reacted sample on PDMS enabling a relatively quick time-to-result.

23 May 2011 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
HBHali Bordelon
Hali Bordelon
NANicholas M. Adams
Nicholas M. Adams
AKAmy S. Klemm
Amy S. Klemm
PRPatricia K. Russ
Patricia K. Russ
JWJohn V Williams
John V Williams
FHFrederick Haselton
Frederick Haselton

10 February 2020 in ACS Applied Materials & Interfaces
Verified
Journal Article
Open access
SPStephanie Irene Pearlman
Stephanie Irene Pearlman
MLMindy Leelawong
Mindy Leelawong
KRKelly A. Richardson
Kelly A. Richardson
NANicholas M. Adams
Nicholas M. Adams
PRPatricia K. Russ
Patricia K. Russ
FHFrederick Haselton
Frederick Haselton
Nucleic acid-based diagnostic tests often require isolation and concentration of nucleic acids from biological samples. Commercial purification kits are difficult to use in low-resource settings due to their cost and insufficient laboratory infrastructure. Several recent approaches based on the use of magnetic beads offer a potential solution, but remain limited to small volume samples. We have developed a simple and low-cost nucleic acid extraction method suitable for isolation and concentration of nucleic acids from small or large sample volumes. The method uses magnetic beads, a transfer pipette, steel wool, and an external magnet to implement high-gradient magnetic separation (HGMS) to retain nucleic acid-magnetic bead complexes within the device’s steel wool matrix for subsequent processing steps. We demonstrate the method’s utility by extracting tuberculosis (TB) DNA from both sputum and urine – two typical large volume sample matrices (5-200 mL) using guanidine-based extraction chemistry. Our HGMS-enabled extraction method is statistically indistinguishable from commercial extraction kits when detecting a spiked 123-base DNA sequence. For our HGMS-enabled extraction method, we obtained extraction efficiencies for sputum and urine of approximately 10% and 90%, while commercial kits obtained 10-17% and 70-96% respectively. We also used this method previously in a blinded sample preparation comparison study published by Beall et al., 2019. Our manual extraction method is insensitive to high flow rates and sample viscosity, with capture of ~100% for flow rates up to 45 mL/min and viscosities up to 55 cP, possibly making it suitable for a wide variety of sample volumes and types and point-of-care users. This HGMS-enabled extraction method provides a robust instrument-free method for magnetic bead-based nucleic acid extraction, potentially suitable for field implementation of nucleic acid testing.

14 January 2004 in Analytical Biochemistry
Verified
Journal Article
Closed access
MMMark K McQuain
Mark K McQuain
KSKevin Seale
Kevin Seale
JPJoel Peek
Joel Peek
TFTimothy S. Fisher
Timothy S. Fisher
SLShawn Levy
Shawn Levy
FHFrederick Haselton
Frederick Haselton