Nicholas M. Adams

Nicholas M. Adams

Auto-generated profile, based on publicly available information

Nicholas M. Adams

Department of Biomedical Engineering, Vanderbilt University, Nashville, USA

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 February 2020 in ACS Applied Materials & Interfaces
Verified
Journal Article
Open access
SPStephanie Irene Pearlman
Stephanie Irene Pearlman
MLMindy Leelawong
Mindy Leelawong
KRKelly A. Richardson
Kelly A. Richardson
NANicholas M. Adams
Nicholas M. Adams
PRPatricia K. Russ
Patricia K. Russ
FHFrederick Haselton
Frederick Haselton
Nucleic acid-based diagnostic tests often require isolation and concentration of nucleic acids from biological samples. Commercial purification kits are difficult to use in low-resource settings due to their cost and insufficient laboratory infrastructure. Several recent approaches based on the use of magnetic beads offer a potential solution, but remain limited to small volume samples. We have developed a simple and low-cost nucleic acid extraction method suitable for isolation and concentration of nucleic acids from small or large sample volumes. The method uses magnetic beads, a transfer pipette, steel wool, and an external magnet to implement high-gradient magnetic separation (HGMS) to retain nucleic acid-magnetic bead complexes within the device’s steel wool matrix for subsequent processing steps. We demonstrate the method’s utility by extracting tuberculosis (TB) DNA from both sputum and urine – two typical large volume sample matrices (5-200 mL) using guanidine-based extraction chemistry. Our HGMS-enabled extraction method is statistically indistinguishable from commercial extraction kits when detecting a spiked 123-base DNA sequence. For our HGMS-enabled extraction method, we obtained extraction efficiencies for sputum and urine of approximately 10% and 90%, while commercial kits obtained 10-17% and 70-96% respectively. We also used this method previously in a blinded sample preparation comparison study published by Beall et al., 2019. Our manual extraction method is insensitive to high flow rates and sample viscosity, with capture of ~100% for flow rates up to 45 mL/min and viscosities up to 55 cP, possibly making it suitable for a wide variety of sample volumes and types and point-of-care users. This HGMS-enabled extraction method provides a robust instrument-free method for magnetic bead-based nucleic acid extraction, potentially suitable for field implementation of nucleic acid testing.

11 September 2011 in Langmuir
Verified
Journal Article
Closed access
NANicholas M. Adams
Nicholas M. Adams
SJStephen R. Jackson
Stephen R. Jackson
FHFrederick Haselton
Frederick Haselton
David W. WrightDavid W. Wright
David W. Wright

17 May 2019 in Analytical Methods
Verified
Journal Article
Closed access
PDF file
ZZZackary Zimmers
Zackary Zimmers
NANicholas M. Adams
Nicholas M. Adams
WGWilliam E. Gabella
William E. Gabella
FHFrederick Haselton
Frederick Haselton
The distance between fluorophore and quencher affects the melting temperature of fluorescently-labeled DNA.

6 August 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
EEErin M. Euliano
Erin M. Euliano
AHAustin N. Hardcastle
Austin N. Hardcastle
CVChristia M. Victoriano
Christia M. Victoriano
WGWilliam E. Gabella
William E. Gabella
FHFrederick Haselton
Frederick Haselton
NANicholas M. Adams
Nicholas M. Adams
Reverse transcription polymerase chain reaction (RT-PCR) is the gold standard for the molecular diagnosis of many infectious diseases, including RNA viruses, but is generally limited to settings with access to trained personnel and laboratory resources. We have previously reported a fundamentally simpler thermal cycling platform called Adaptive PCR, which dynamically controls thermal cycling conditions during each cycle by optically monitoring the annealing and melting of mirror-image L-DNA surrogates of the PCR primers and targets. In this report, we integrate optically-controlled reverse transcription and single-channel monitoring of L-DNAs to develop a multiplexed Adaptive RT-PCR instrument and assay for the detection of Zika, dengue, and chikungunya virus RNA with high target specific and low limits of detection. The assay is demonstrated to detect as low as 5 copies/reaction of Zika or chikungunya RNA and 50 copies/reaction of dengue RNA. The multiplexed Adaptive RT-PCR instrument is robust and has many of the features required to implement diagnostic assays for RNA viruses in settings that lack traditional laboratory resources.

7 December 2016 in Analytical Chemistry
Verified
Journal Article
Closed access
NANicholas M. Adams
Nicholas M. Adams
WGWilliam E. Gabella
William E. Gabella
AHAustin N. Hardcastle
Austin N. Hardcastle
FHFrederick Haselton
Frederick Haselton

1 August 2009 in American Journal of Infection Control
Verified
Journal Article
Closed access
JOJonathan A. Otter
Jonathan A. Otter
NHNancy Havill
Nancy Havill
NANicholas M.T. Adams
Nicholas M.T. Adams
TCTimothea Cooper
Timothea Cooper
ATAllison Tauman
Allison Tauman
JBJohn M. Boyce
John M. Boyce