Marinella Sandros

Dr. Marinella Sandros


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 May 2014 in Scientific Reports
Verified
Journal Article
Open access
SVStephen A. Vance
Stephen A. Vance
MSMarinella Sandros
Marinella Sandros
Diagnostic biomarkers (i.e. proteins) are often in low abundance in bodily fluids presenting many challenges for their detection. In order to extend the application of SPRi systems in detecting biomarkers at ultralow levels, we combine the advantage of aptamer technology with nanomaterials and microwave-assisted surface functionalization. By implementing a sandwich assay through the introduction of aptamer-modified quantum dots (QDs), it was possible to measure 7 zeptomole (at 5 fg/mL) of C-reactive protein (CRP) selectively in spiked human serum. It is expected that the proposed platform will provide new direction in designing ultrasensitive SPRi biosensors with multiplexing capabilities.

1 January 2013 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Open access
PDF file
ADAnthony Dellinger
Anthony Dellinger
JOJohn Olson
John Olson
KLKerry Link
Kerry Link
SVStephen Vance
Stephen Vance
MSMarinella Sandros
Marinella Sandros
CKChristopher L Kepley
Christopher L Kepley
The hallmark of atherosclerosis is the accumulation of plaque in vessel walls. This process is initiated when monocytic cells differentiate into macrophage foam cells under conditions with high levels of atherogenic lipoproteins. Vulnerable plaque can dislodge, enter the blood stream, and result in acute myocardial infarction and stroke. Imaging techniques such as cardiovascular magnetic resonance (CMR) provides one strategy to identify patients with plaque accumulation.

1 October 2014 in Colloids and Surfaces B: Biointerfaces
Verified
Journal Article
Closed access
KBKristen Bowey
Kristen Bowey
JTJean-François Tanguay
Jean-François Tanguay
MSMarinella Sandros
Marinella Sandros
MTMaryam Tabrizian
Maryam Tabrizian

7 January 2016 in Journal of Visualized Experiments
Verified
Journal Article
Open access
PDF file
SVStephen Vance
Stephen Vance
EZEffat Zeidan
Effat Zeidan
VHVincent C. Henrich
Vincent C. Henrich
MSMarinella Sandros
Marinella Sandros
Sensitive and selective methods for the detection of human growth hormone (hGH) over a wide range of concentrations (high levels of 50-100 ng ml−1 and minimum levels of 0.03 ng ml−1) in circulating blood are essential as variable levels may indicate altered physiology. For example, growth disorders occurring in childhood can be diagnosed by measuring levels of hGH in blood. Also, the misuse of recombinant hGH in sports not only poses an ethical issue it also presents serious health threats to the abuser. One popular strategy for measuring hGH misuse, relies on the detection of the ratio of 22 kDa hGH to total hGH, as non-22 kDa endogenous levels drop after exogenous recombinant hGH (rhGH) administration. Surface plasmon resonance imaging (SPRi) is an analytical tool that allows direct (label-free) monitoring and visualization of biomolecular interactions by recording changes of the refractive index adjacent to the sensor surface in real time. In contrast, the most frequently used colorimetric method, enzyme-linked immunosorbent assay (ELISA) uses enzyme labeled detection antibodies to indirectly measure analyte concentration after the addition of a substrate that induces a color change. To increase detection sensitivity, amplified SPRi uses a sandwich assay format and near infrared quantum dots (QDs) to increase signal strength. After direct SPRi detection of recombinant rhGH in spiked human serum, the SPRi signal is amplified by the sequential injection of detection antibody coated with near-infrared QDs (Nano-SPRi). In this study, the diagnostic potential of direct and amplified SPRi was assessed for measuring rhGH spiked in human serum and compared directly with the capabilities of a commercially available ELISA kit.