Kristian Welle

Dr. Kristian Welle

Department of Orthopedics and Trauma Surgery, University Hospital of Bonn, 53127 Bonn, Germany

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 April 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
RHRoslind K. Hackenberg
Roslind K. Hackenberg
FSFabio Schmitt-Sánchez
Fabio Schmitt-Sánchez
CEChristoph Hans Jürgen Endler
Christoph Hans Jürgen Endler
VTVerena Tischler
Verena Tischler
SJSurendar Jayagopi
Surendar Jayagopi
Frank A. SchildbergFrank A. Schildberg
Frank A. Schildberg
Osteomyelitis (OM) remains one of the most feared complications in bone surgery and trauma. Its diagnosis remains a major challenge due to lack of guidelines. The aim of this study was to prospectively analyze the value of the most common and available diagnostic tools and to establish an OM score to derive treatment recommendations. All patients with suspected OM were included in a prospective pilot study. All patients underwent blood sampling for C-reactive protein and white blood cell count analysis. Magnetic resonance imaging (MRI), and microbiologic and histopathologic samples, were taken from representative sites of initial debridement. All patients were treated according to their OM test results and followed for at least one year. Subsequently, the value of individual or combined diagnostic tools was analyzed in patients with confirmed OM and in patients in whom OM was ruled out. Based on these findings, an OM score was developed that included MRI, microbiology, and histopathology. The score identified all control patients and all but one OM patient, resulting in a correct diagnosis of 93.3%, which was validated in a second independent larger cohort. This was the first study to analyze the value of the most commonly used tools to diagnose OM. The proposed OM score provides a simple scoring system to safely interpret test results with high accuracy.

19 May 2022 in Scientific Reports
Verified
Journal Article
Open access
PDF file
KWKristian Welle
Kristian Welle
STStefan Taeger
Stefan Taeger
CPChristian Prangenberg
Christian Prangenberg
RHRoslind Karolina Hackenberg
Roslind Karolina Hackenberg
JKJan-Dirk Kieback
Jan-Dirk Kieback
KKKoroush Kabir
Koroush Kabir
The treatment of scaphoid nonunion can be challenging with increasing defect size. We evaluated the outcome of scaphoid nonunion with a substantial bone defect treated with a multidirectional locking plate combined with cancellous bone grafting only. Thirteen patients with significant osseous defects measuring 6 mm or more suffering from primary nonunion without treatment (n = 6) or recalcitrant nonunion following Herbert screw osteosynthesis (n = 7) were treated and reviewed retrospectively. The stabilization was performed after debridement, autologous cancellous bone grafting and volar locking plate osteosynthesis. After a mean follow-up period of 12 months, 12 of the 13 patients achieved successful unions with a free range of motion and complete remittance of pain in everyday activity. The mean scapholunate angle decreased from 59.7° ± 11 to 43.9° ± 5 (effect strength d:1.7, p < 0.00001), scaphoid humpback deformity angle from 58.9° ± 8 to 45.1° ± 8 (d:1.8, p < 0.0001), whereas strength of the injured hand increased from 36.4 kg ± 10 to 42.4 kg ± 9 (d:1.4, p < 0.0001). One nonunion persisted without fragment dislocation receiving revision after 1 year. Thus, locking plate osteosynthesis with cancellous bone grafting is a valid alternative in scaphoid nonunions with extensive bone defects. Additionally, stable retention of the fragments prevents dislocation even in delayed or persistent nonunion. Further prospective studies are required to confirm these findings.

13 May 2022 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
KWKristian Welle
Kristian Welle
CPChristian Prangenberg
Christian Prangenberg
RHRoslind K. Hackenberg
Roslind K. Hackenberg
MGMartin Gathen
Martin Gathen
FDFaramarz Dehghani
Faramarz Dehghani
KKKoroush Kabir
Koroush Kabir
Background: Surgery for humeral shaft fractures is associated with a high risk of iatrogenic radial nerve palsy (RNP). Plausible causes are difficult anatomical conditions and variants. Methods: We performed a cadaveric study with 23 specimens (13 female and 10 male Caucasian donors) to assess the course and anatomy of the radial nerve (RN) with its branches alongside the humeral shaft. The accuracy of identification of the RN in the surgical field was analyzed by measuring the location, course, diameter, and form of each nerve and vessel of interest. Results: The RN is not a single structure running alongside the humeral shaft; at least 4 parallel structures crossed the dorsal humerus in all subjects. The RN was accompanied by 2 vessels and at least 1 other nerve, which we named the musculocutaneous branch (MCB). With an oval profile and an average diameter of 3.1 mm (range, 2.6 to 3.8 mm), the MCB was thinner but, in some cases, close to the average diameter of 4.7 mm (range, 4.0 to 5.2 mm) of the RN, which had a round profile. Both accompanying vessels had similar diameters: 3.5 mm (range, 2.6 to 4.2 mm) for the radial collateral artery and 4.0 mm (range, 2.9 to 4.4 mm) for the medial collateral artery. In 20 (87%) of the cases, the RN ran proximal to and in 3 (13%) of the cases, distal to the MCB. Furthermore, a distal safe zone of at least 110 mm (range, 110 to 160 mm) was found, measured from the radial (lateral) epicondyle proximally. Conclusions: The RN does not cross the dorsal humerus alone, as often stated in anatomical textbooks, but runs parallel to vessels and at least 1 nerve branch with a similar appearance. Thus, for reliable preservation of the RN, we recommend identification and protection of all crossing structures in posterior humeral surgeries 110 mm proximal to the radial epicondyle.

31 December 2024 in Cells
Verified
Journal Article
Open access
PDF file
RORobert Ossendorff
Robert Ossendorff
SKSarah Kurth
Sarah Kurth
Su WangSu Wang
Su Wang
MJMax Jaenisch
Max Jaenisch
EAElio Assaf
Elio Assaf
Frank A. SchildbergFrank A. Schildberg
Frank A. Schildberg
Inflammation models with the proinflammatory cytokine interleukin-1β (IL-1β) are widely used in the in vitro investigation of new therapeutic approaches for osteoarthritis (OA). The aim of this study was to systematically analyze the influence of IL-1β in a 3D chondral pellet culture model. Bovine articular chondrocytes were cultured to passage 3 and then placed in pellet culture. Titration of IL-1β (100–0.1 ng/mL) was performed with both human and bovine recombinant protein in chondrocyte culture for 2 weeks. Gene expression of anabolic (collagen 2, aggrecan, cartilage oligomeric protein (COMP), proteoglycan-4 (PRG-4)), catabolic matrix metallo proteinases (MMP-3, MMP-13), dedifferentiation (collagen 1) markers and inflammatory cytokines IL-6 and IL-8 was determined. Analysis of the cell culture medium was performed for the inflammatory markers IL-6 and nitric oxide (NO). In general, the influence of IL-1β was shown by a decrease in the expression of anabolic markers (collagen 2, aggrecan, PRG-4), whereas the catabolic markers MMP-3 and MMP-13 as well as the inflammatory markers IL-6 and IL-8 were significantly increased. This was observed both at the early time point (day 4) and at the late time point (day 14). The described inflammatory effects were confirmed by increased concentration-dependent release of NO and IL-6. The threshold concentration for a detectable effect compared to control differed between groups, but was reached earlier by homologous application of IL-1β. This study provides a systematic evaluation of IL-1β-specific effects on chondrocytes in a 3D pellet culture model, which is highly relevant for comparisons of studies in OA-specific drug development.

20 August 2023 in Bioengineering
Verified
Journal Article
Open access
PDF file
AKAxel Klemeit
Axel Klemeit
AWAnna Weber
Anna Weber
CBChristoph P Bourauel
Christoph P Bourauel
KWKristian Welle
Kristian Welle
Christof BurgerChristof Burger
Christof Burger
CDChristoph Deborre
Christoph Deborre
Monolateral pin-to-bar-clamp fixators are commonly used to stabilize acute extremity injuries. Certain rules regarding frame geometry have been established that affect construct stability. The influence of sagittal pin angulation on construct stiffness and strength has not been investigated. The purpose of this biomechanical study was to demonstrate the effect of a pin angulation in the monolateral fixator using a composite cylinder model. Three groups of composite cylinder models with a fracture gap were loaded with different mounting variants of monolateral pin-to-bar-clamp fixators. In the first group, the pins were set parallel to each other and perpendicular to the specimen. In the second group, both pins were set convergent each in an angle of 15° to the specimen. In the third group, the pins were set each 15° divergent. The strength of the constructions was tested using a mechanical testing machine. This was followed by a cyclic loading test to produce pin loosening. A pull-out test was then performed to evaluate the strength of each construct at the pin–bone interface. Initial stiffness analyses showed that the converging configuration was the stiffest, while the diverging configuration was the least stiff. The parallel mounting showed an intermediate stiffness. There was a significantly higher resistance to pull-out force in the diverging pin configuration compared to the converging pin configuration. There was no significant difference in the pull-out strength of the parallel pins compared to the angled pin pairs. Convergent mounting of pin pairs increases the stiffness of a monolateral fixator, whereas a divergent mounting weakens it. Regarding the strength of the pin–bone interface, the divergent pin configuration appears to provide greater resistance to pull-out force than the convergent one. The results of this pilot study should be important for the doctrine of fixator mounting as well as for fixator component design.

3 March 2021 in Der Unfallchirurg
Verified
Journal Article
Closed access
PDF file
MWMarkus Walz
Markus Walz
Christof BurgerChristof Burger
Christof Burger
KKKoroush Kabir
Koroush Kabir
KWKristian Welle
Kristian Welle
ULUlrich Liener
Ulrich Liener
HGHans Goost
Hans Goost