Christoph P Bourauel

Prof. Dr. Christoph P Bourauel

orcid

Research Focus & Metrics

Academic Career Length

37Years (1990-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 June 2014 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
MSMareike Simon
Mareike Simon
LKLudger Keilig
Ludger Keilig
JSJörg Schwarze
Jörg Schwarze
Britta A. JungBritta A. Jung
Britta A. Jung
CBChristoph P Bourauel
Christoph P Bourauel
The aim of this study was to investigate the efficacy of orthodontic treatment using the Invisalign® system. Particularly, we analyzed the influence of auxiliaries (Attachment/Power Ridge) as well as the staging (movement per aligner) on treatment efficacy. We reviewed the tooth movements of 30 consecutive patients who required orthodontic treatment with Invisalign®. In all patients, one of the following tooth movements was performed: (1) Incisor Torque >10°, (2) Premolar derotation >10° (3) Molar distalization >1.5 mm. The groups (1)-(3) were subdivided: in the first subgroup (a) the movements were supported with the use of an attachment, while in the subgroup (b) no auxiliaries were used (except incisor torque, in which Power Ridges were used). All tooth movements were performed in a split-mouth design. To analyze the clinical efficacy, pre-treatment and final plaster cast models were laser-scanned and the achieved tooth movement was determined by way of a surface/surface matching algorithm. The results were compared with the amount of tooth movement predicted by ClinCheck®. The overall mean efficacy was 59% (SD = 0.2). The mean accuracy for upper incisor torque was 42% (SD = 0.2). Premolar derotation showed the lowest accuracy with approximately 40% (SD = 0.3). Distalization of an upper molar was the most effective movement, with efficacy approximately 87% (SD = 0.2). Incisor torque, premolar derotation and molar distalization can be performed using Invisalign® aligners. The staging (movement/aligner) and the total amount of planned movement have an significant impact on treatment efficacy.

1 March 1999 in Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie
Verified
Journal Article
Closed access
PDF file
CBChristoph P Bourauel
Christoph P Bourauel
DFDieter Freudenreich
Dieter Freudenreich
DVDirk Vollmer
Dirk Vollmer
DKDagmar Kobe
Dagmar Kobe
DDDieter Drescher
Dieter Drescher
AJAndreas Jäger
Andreas Jäger

1 January 2000 in Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie
Verified
Journal Article
Closed access
PDF file
CBChristoph P Bourauel
Christoph P Bourauel
DVDirk Vollmer
Dirk Vollmer
AJAndreas Jäger
Andreas Jäger

25 December 2023 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Open access
IAIslam Atta
Islam Atta
CBChristoph P Bourauel
Christoph P Bourauel
YAYasmine Alkabani
Yasmine Alkabani
NMNesreen Mohamed
Nesreen Mohamed
Hoon KimHoon Kim
Hoon Kim
Tarek M. ElshazlyTarek M. Elshazly
Tarek M. Elshazly
To conduct a physiochemical and mechanical material analysis on 3D printed shape-memory aligners in comparison to thermoformed aligners. Four materials were examined, including three thermoformed materials: CA Pro (CP), Zendura A (ZA), Zendura FLX (ZF), and one 3D printed material: Tera Harz (TC-85). Rectangular strips measuring 50 × 10 × 0.5 mm were produced from each material. Five tests were conducted, including differential scanning calorimetry (DSC), dynamic mechanical analysis (DMA), shape recovery tests, three-points bending (3 PB), and Vickers surface microhardness (VH). DSC recorded glass transition temperatures (Tg) at 79.9 °C for CP, 92.2 °C for ZA, 107.1 °C for ZF, and 42.3 °C for TC-85. In DMA analysis at 20-45 °C, a prominent decrease in storage modulus was observed, exclusively for TC-85, as the temperature increased. Notably, within the temperature range of 30-45 °C, TC-85 exhibited substantial shape recovery after 10 min, reaching up to 86.1 %, while thermoformed materials showed minimal recovery (1.5-2.9 %). In 3 PB test (at 30, 37, 45 °C), ZA demonstrated the highest force at 2 mm bending, while TC-85 exhibited the lowest. Regarding VH at room temperature, there was a significant decrease for both ZA and ZF after thermoforming. ZA had the highest hardness, followed by ZF and TC-85, with CP showing the lowest values. TC-85 demonstrates exceptional shape memory at oral temperature, improving adaptation, reducing force decay, and enabling, together with its higher flexibility, extensive tooth movement per step. Additionally, it maintains microhardness similar to thermoformed sheets, ensuring the durability and effectiveness of dental aligners. The 3D printed aligner material with shape memory characteristics (4D aligner) has revolutionized the orthodontic aligner field. It showed mechanical properties more suitable for orthodontic treatment than thermoforming materials. Additionally, it offers enhanced control over aligner design and thickness, while optimizing the overall workflow. It also minimizes material wastage, and reduces production expenses.

1 August 2005 in European Journal of Orthodontics
Verified
Journal Article
Open access
PDF file
AZA. Ziegler
A. Ziegler
LKL. Keilig
L. Keilig
AKA. Kawarizadeh
A. Kawarizadeh
AJA. Jäger
A. Jäger
CBChristoph P Bourauel
Christoph P Bourauel
The elastic properties of the periodontal ligament (PDL) in eight multi-rooted teeth were examined in a combined experimental and numerical study in six minipigs. The initial tooth movement of the mandibular primary molars surrounded by the periodontium was registered three-dimensionally (3D) in an optomechanical measuring system. The dissections were then embedded in resin and cut in transverse sections. Based on these sections, 3D finite element (FE) models were constructed and numerically loaded with the same force systems as used in the experiment. The material behaviour of the PDL registered in the experiment was non-linear and could be approximated with a bilinear parameter set consisting of two Young's moduli, E1 and E2, and one ultimate strain, ε12, separating both elastic regimes. When a deficient congruence existed between the experimental and numerical force/deflection curves the material parameters were varied to obtain a satisfactory congruence. The material behaviour determined for these specimens delivered mean values of E1 = 0.05 MPa, E2 = 0.18 MPa and ε12 = 6.4 per cent for the elastic behaviour of the multi-rooted minipig teeth. There was no significant difference in the material parameters determined for specimens with two, four or six roots. The results were in close agreement with the material parameters of the PDL, determined in previous investigations of single-rooted human and pig teeth.

4 July 2023 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
ARAshraf Refaie
Ashraf Refaie
AFAhmed Fouda
Ahmed Fouda
CBChristoph P Bourauel
Christoph P Bourauel
LSLamia Singer
Lamia Singer
Background: This study aimed to evaluate and compare the marginal gap using two different methods and the internal fit of 3D printed and zirconia crowns. Methods: 3Y-TZP zirconia crowns (n = 20) were manufactured using subtractive milling (group M) and 3D printed (group P). The marginal gap was measured at 60 points using vertical marginal gap technique (VMGT). On the other hand, the silicone replica technique (SRT) was used to evaluate the internal fit and was divided into 4 groups: marginal gap, cervical gap, axial gap, and occlusal gap where the thickness of light impression was measured at 16 references. The numerical data was tested for normality using Shapiro–Wilk's test. They were found to be normally distributed and were analyzed using an independent t-test. Results: Using VMGT, group P had significantly higher mean marginal gap values of 80 ± 30 µm compared to group M = 60 ± 20 µm (p < 0.001). Also, with the SRT, the marginal gap of group P (100 ± 10 µm) had significantly higher values compared to group M (60 ± 10 µm). The internal fit showed significant difference between the tested groups except for Axial Gap. Conclusions: Although milled crowns showed better results. The 3D printed zirconia crowns offer clinically acceptable results in terms of marginal adaptation and internal fit. Both VMGT and SRT are reliable methods for the assessment of the marginal gap.