Nicolas Garcia-Aracil

Dr. Nicolas Garcia-Aracil

orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 July 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
SCSimona Crea
Simona Crea
MNMarius Nann
Marius Nann
ETEmilio Trigili
Emilio Trigili
FCFrancesca Cordella
Francesca Cordella
ABAndrea Baldoni
Andrea Baldoni
SSSurjo R. Soekadar
Surjo R. Soekadar
Arm and finger paralysis, e.g. due to brain stem stroke, often results in the inability to perform activities of daily living (ADLs) such as eating and drinking. Recently, it was shown that a hybrid electroencephalography/electrooculography (EEG/EOG) brain/neural hand exoskeleton can restore hand function to quadriplegics, but it was unknown whether such control paradigm can be also used for fluent, reliable and safe operation of a semi-autonomous whole-arm exoskeleton restoring ADLs. To test this, seven abled-bodied participants (seven right-handed males, mean age 30 ± 8 years) were instructed to use an EEG/EOG-controlled whole-arm exoskeleton attached to their right arm to perform a drinking task comprising multiple sub-tasks (reaching, grasping, drinking, moving back and releasing a cup). Fluent and reliable control was defined as average ‘time to initialize’ (TTI) execution of each sub-task below 3 s with successful initializations of at least 75% of sub-tasks within 5 s. During use of the system, no undesired side effects were reported. All participants were able to fluently and reliably control the vision-guided autonomous whole-arm exoskeleton (average TTI 2.12 ± 0.78 s across modalities with 75% successful initializations reached at 1.9 s for EOG and 4.1 s for EEG control) paving the way for restoring ADLs in severe arm and hand paralysis.

6 August 2011 in Medical & Biological Engineering & Computing
Verified
Journal Article
Closed access
PDF file
RMRicardo Morales
Ricardo Morales
FBFrancisco Javier Badesa
Francisco Javier Badesa
NGNicolas Garcia-Aracil
Nicolas Garcia-Aracil
Jose Maria Sabater-NavarroJose Maria Sabater-Navarro
Jose Maria Sabater-Navarro
CPCarlos Pérez-Vidal
Carlos Pérez-Vidal

5 December 2005 in IEEE Transactions on Robotics
Verified
Journal Article
Closed access
NGNicolas Garcia-Aracil
Nicolas Garcia-Aracil
EME. Malis
E. Malis
RAR. Aracil-Santonja
R. Aracil-Santonja
CPC. Perez-Vidal
C. Perez-Vidal
In the recent past, the visibility problem in vision-based control has been widely investigated. The proposed solutions generally have a common goal: to always keep the object in the camera's field of view during the visual servoing. Contrary to this solution, we propose a new approach based on the concept of allowing the changes of visibility in image features during the control task. To this aim, the camera invariant visual-servoing approach has been redefined in order to take into account the changes of visibility in image features. A new smooth task function using weighted features is presented, and a continuous control law is obtained starting from it by imposing its exponential decrease to zero. Furthermore, the local stability analysis of the invariant visual-servoing approach with weighted features is presented. Finally, this promising way of dealing with the visibility issue has been successfully tested with an eye-in-hand robotic system.

1 September 2014 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Closed access
FBFrancisco Javier Badesa
Francisco Javier Badesa
RMRicardo Morales
Ricardo Morales
NGNicolas Garcia-Aracil
Nicolas Garcia-Aracil
Jose Maria Sabater-NavarroJose Maria Sabater-Navarro
Jose Maria Sabater-Navarro
Alicia CasalsAlicia Casals
Alicia Casals
LZLoredana Zollo
Loredana Zollo

17 September 2020 in IEEE Systems Journal
Verified
Journal Article
Closed access
MNMarius Nann
Marius Nann
Francesca CordellaFrancesca Cordella
Francesca Cordella
ETEmilio Trigili
Emilio Trigili
Clemente LaurettiClemente Lauretti
Clemente Lauretti
MBMarco Bravi
Marco Bravi
SSSurjo R. Soekadar
Surjo R. Soekadar
Stroke survivors with chronic paralysis often have difficulties to perform various activities of daily living (ADLs), such as preparing a meal or eating and drinking independently. Recently, it was shown that a brain/neural hand exoskeleton can restore hand and finger function, but many stroke survivors suffer from motor deficits affecting their whole upper limb. Therefore, novel hybrid electroencephalography/electrooculography (EEG/EOG)-based brain/neural control paradigms were developed for guiding a whole-arm exoskeleton. It was unclear, however, whether hemiplegic stroke survivors are able to reliably use such brain/neural-controlled device. Here, we tested feasibility, safety, and user-friendliness of EEG/EOG-based brain/neural robotic control across five hemiplegic stroke survivors engaging in a drinking task that consisted of several subtasks (e.g., reaching, grasping, manipulating, and drinking). Reliability was assumed when at least 75% of subtasks were initialized within 3 s. Fluent control was assumed if average “time to initialize” each subtask ranged below 3 s. System's safety and user-friendliness were rated using Likert-scales. All chronic stroke patients were able to operate the system reliably and fluently. No undesired side effects were reported. Four participants rated the system as very user-friendly. These results show that chronic stroke survivors are capable of using an EEG/EOG-controlled semiautonomous whole-arm exoskeleton restoring ADLs.

20 February 2018 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
ABArturo Bertomeu-Motos
Arturo Bertomeu-Motos
AIAndrea Blanco Ivorra
Andrea Blanco Ivorra
FBFrancisco Javier Badesa
Francisco Javier Badesa
JBJuan A. Barios
Juan A. Barios
LZLoredana Zollo
Loredana Zollo
NGNicolas Garcia-Aracil
Nicolas Garcia-Aracil
End-effector robots are commonly used in robot-assisted neuro-rehabilitation therapies for upper limbs where the patient’s hand can be easily attached to a splint. Nevertheless, they are not able to estimate and control the kinematic configuration of the upper limb during the therapy. However, the Range of Motion (ROM) together with the clinical assessment scales offers a comprehensive assessment to the therapist. Our aim is to present a robust and stable kinematic reconstruction algorithm to accurately measure the upper limb joints using only an accelerometer placed onto the upper arm. The proposed algorithm is based on the inverse of the augmented Jaciobian as the algorithm (Papaleo, et al., Med Biol Eng Comput 53(9):815–28, 2015). However, the estimation of the elbow joint location is performed through the computation of the rotation measured by the accelerometer during the arm movement, making the algorithm more robust against shoulder movements. Furthermore, we present a method to compute the initial configuration of the upper limb necessary to start the integration method, a protocol to manually measure the upper arm and forearm lengths, and a shoulder position estimation. An optoelectronic system was used to test the accuracy of the proposed algorithm whilst healthy subjects were performing upper limb movements holding the end effector of the seven Degrees of Freedom (DoF) robot. In addition, the previous and the proposed algorithms were studied during a neuro-rehabilitation therapy assisted by the ‘PUPArm’ planar robot with three post-stroke patients. The proposed algorithm reports a Root Mean Square Error (RMSE) of 2.13cm in the elbow joint location and 1.89cm in the wrist joint location with high correlation. These errors lead to a RMSE about 3.5 degrees (mean of the seven joints) with high correlation in all the joints with respect to the real upper limb acquired through the optoelectronic system. Then, the estimation of the upper limb joints through both algorithms reveal an instability on the previous when shoulder movement appear due to the inevitable trunk compensation in post-stroke patients. The proposed algorithm is able to accurately estimate the human upper limb joints during a neuro-rehabilitation therapy assisted by end-effector robots. In addition, the implemented protocol can be followed in a clinical environment without optoelectronic systems using only one accelerometer attached in the upper arm. Thus, the ROM can be perfectly determined and could become an objective assessment parameter for a comprehensive assessment.