Juan Antonio Barios

Juan Antonio Barios

Auto-generated profile, based on publicly available information

Juan Antonio Barios

Miguel Hernandez University

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2016 in Acta Biomaterialia
Verified
Journal Article
Closed access
LFLaura Fernández-García
Laura Fernández-García
NMNúria Marí-Buyé
Núria Marí-Buyé
JBJuan A. Barios
Juan A. Barios
RMRodrigo Madurga
Rodrigo Madurga
MEManuel Elices
Manuel Elices
DGDaniel Gonzalez-Nieto
Daniel Gonzalez-Nieto

20 February 2018 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
ABArturo Bertomeu-Motos
Arturo Bertomeu-Motos
AIAndrea Blanco Ivorra
Andrea Blanco Ivorra
FBFrancisco Javier Badesa
Francisco Javier Badesa
JBJuan A. Barios
Juan A. Barios
LZLoredana Zollo
Loredana Zollo
NGNicolas Garcia-Aracil
Nicolas Garcia-Aracil
End-effector robots are commonly used in robot-assisted neuro-rehabilitation therapies for upper limbs where the patient’s hand can be easily attached to a splint. Nevertheless, they are not able to estimate and control the kinematic configuration of the upper limb during the therapy. However, the Range of Motion (ROM) together with the clinical assessment scales offers a comprehensive assessment to the therapist. Our aim is to present a robust and stable kinematic reconstruction algorithm to accurately measure the upper limb joints using only an accelerometer placed onto the upper arm. The proposed algorithm is based on the inverse of the augmented Jaciobian as the algorithm (Papaleo, et al., Med Biol Eng Comput 53(9):815–28, 2015). However, the estimation of the elbow joint location is performed through the computation of the rotation measured by the accelerometer during the arm movement, making the algorithm more robust against shoulder movements. Furthermore, we present a method to compute the initial configuration of the upper limb necessary to start the integration method, a protocol to manually measure the upper arm and forearm lengths, and a shoulder position estimation. An optoelectronic system was used to test the accuracy of the proposed algorithm whilst healthy subjects were performing upper limb movements holding the end effector of the seven Degrees of Freedom (DoF) robot. In addition, the previous and the proposed algorithms were studied during a neuro-rehabilitation therapy assisted by the ‘PUPArm’ planar robot with three post-stroke patients. The proposed algorithm reports a Root Mean Square Error (RMSE) of 2.13cm in the elbow joint location and 1.89cm in the wrist joint location with high correlation. These errors lead to a RMSE about 3.5 degrees (mean of the seven joints) with high correlation in all the joints with respect to the real upper limb acquired through the optoelectronic system. Then, the estimation of the upper limb joints through both algorithms reveal an instability on the previous when shoulder movement appear due to the inevitable trunk compensation in post-stroke patients. The proposed algorithm is able to accurately estimate the human upper limb joints during a neuro-rehabilitation therapy assisted by end-effector robots. In addition, the implemented protocol can be followed in a clinical environment without optoelectronic systems using only one accelerometer attached in the upper arm. Thus, the ROM can be perfectly determined and could become an objective assessment parameter for a comprehensive assessment.

5 January 2018 in PLOS ONE
Verified
Journal Article
Open access
PDF file
LPLeonel Perez-Atencio
Leonel Perez-Atencio
NGNicolas Garcia-Aracil
Nicolas Garcia-Aracil
EFEduardo Buglioni Fernandez
Eduardo Buglioni Fernandez
LBLuis C Barrio
Luis C Barrio
JBJuan A Barios
Juan A Barios
Behavioral states alternate between wakefulness (wk), rapid eye movement (rem) and non-rem (nrem) sleep at time scale of hours i.e., light and dark cycle rhythms and from several tens of minutes to seconds (i.e., brief awakenings during sleep). Using statistical analysis of bout duration, Markov chains of sleep-wk dynamics and quantitative EEG analysis, we evaluated the influence of light/dark (ld) changes on brain function along the sleep-wk cycle. Bout duration (bd) histograms and Kaplan-Meier (km) survival curves of wk showed a bimodal statistical distribution, suggesting that two types of wk do exist: brief-wk (wkb) and long-wk (wkl). Light changes modulated specifically wkl bouts, increasing its duration during active/dark period. In contrast, wkb, nrem and rem bd histograms and km curves did not change significantly along ld cycle. Hippocampal eeg of both types of wk were different: in comparison wkb showed a lower spectral power in fast gamma and fast theta bands and less emg tone. After fitting a four-states Markov chain to mice hypnograms, moreover in states transition probabilities matrix was found that: in dark/active period, state-maintenance probability of wkl increased, and probability of wkl to nrem transition decreased; the opposite was found in light period, favoring the hypothesis of the participation of brief wk into nrem-rem intrinsic sleep cycle, and the role of wkl in SWS homeostasis. In conclusion, we propose an extended Markov model of sleep using four stages (wkl, nrem, rem, wkb) as a fully adequate model accounting for both modulation of sleep-wake dynamics based on the differential regulation of long-wk (high gamma/theta) epochs during dark and light phases.

29 May 2019 in International Journal of Neural Systems
Verified
Journal Article
Closed access
PDF file
JBJuan A. Barios
Juan A. Barios
SESantiago Ezquerro
Santiago Ezquerro
ABArturo Bertomeu-Motos
Arturo Bertomeu-Motos
MNMarius Nann
Marius Nann
FBFco. Javier Badesa
Fco. Javier Badesa
NGNicolas Garcia-Aracil
Nicolas Garcia-Aracil

30 September 2015 in Journal of Cerebral Blood Flow & Metabolism
Verified
Journal Article
Open access
PDF file
JBJuan A Barios
Juan A Barios
LPLiudmila Pisarchyk
Liudmila Pisarchyk
LFLaura Fernandez-Garcia
Laura Fernandez-Garcia
LBLuis C Barrio
Luis C Barrio
MRMilagros Ramos
Milagros Ramos
DGDaniel Gonzalez-Nieto
Daniel Gonzalez-Nieto
A constant challenge in experimental stroke is the use of appropriate tests to identify signs of recovery and adverse effects linked to a particular therapy. In this study, we used a long-term longitudinal approach to examine the functional brain changes associated with cortical infarction in a mouse model induced by permanent ligation of the middle cerebral artery (MCA). Sensorimotor function and somatosensory cortical activity were evaluated with fault-foot and forelimb asymmetry tests in combination with somatosensory evoked potentials. The stroke mice exhibited both long-term deficits in the functional tests and impaired responses in the infarcted and intact hemispheres after contralateral and ipsilateral forepaw stimulation. In the infarcted hemisphere, reductions in the amplitudes of evoked responses were detected after contralateral and ipsilateral stimulation. In the intact hemisphere, and similar to cortical stroke patients, a gradual hyperexcitability was observed after contralateral stimulation but no parallel evidence of a response was detected after ipsilateral stimulation. Our results suggest the existence of profound and persistent changes in the somatosensory cortex in this specific mouse cortical stroke model. The study of evoked potentials constitutes a feasible and excellent tool for evaluating the fitness of the somatosensory cortex in relation to functional recovery after preclinical therapeutic intervention.

16 January 2019 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
ABArturo Bertomeu-Motos
Arturo Bertomeu-Motos
SGSantiago Ezquerro García
Santiago Ezquerro García
JBJuan A. Barios
Juan A. Barios
LPLuis Daniel Lledo Perez
Luis Daniel Lledo Perez
SDSergio Domingo
Sergio Domingo
NGNicolas Garcia-Aracil
Nicolas Garcia-Aracil
Assistive technologies aim to increase quality of life, reduce dependence on care giver and on the long term care system. Several studies have demonstrated the effectiveness in the use of assistive technology for environment control and communication systems. The progress of brain-computer interfaces (BCI) research together with exoskeleton enable a person with motor impairment to interact with new elements in the environment. This paper aims to evaluate the environment control interface (ECI) developed under the AIDE project conditions, a multimodal interface able to analyze and extract relevant information from the environments as well as from the identification of residual abilities, behaviors, and intentions of the user. This study evaluated the ECI in a simulated scenario using a two screen layout: one with the ECI and the other with a simulated home environment, developed for this purpose. The sensorimotor rhythms and the horizontal oculoversion, acquired through BCI2000, a multipurpose standard BCI platform, were used to online control the ECI after the user training and system calibration. Eight subjects with different neurological diseases and spinal cord injury participated in this study. The subjects performed simulated activities of daily living (ADLs), i.e. actions in the simulated environment as drink, switch on a lamp or raise the bed head, during ten minutes in two different modes, AIDE mode, using a prediction model, to recognize the user intention facilitating the scan, and Manual mode, without a prediction model. The results show that the mean task time spent in the AIDE mode was less than in the Manual, i.e the users were able to perform more tasks in the AIDE mode during the same time. The results showed a statistically significant differences with p<0.001. Regarding the steps, i.e the number of abstraction levels crossed in the ECI to perform an ADL, the users performed one step in the 90% of the tasks using the AIDE mode and three steps, at least, were necessary in the Manual mode. The user’s intention prediction was performed through conditional random fields (CRF), with a global accuracy about 87%. The environment analysis and the identification of the user’s behaviors can be used to predict the user intention opening a new paradigm in the design of the ECIs. Although the developed ECI was tested only in a simulated home environment, it can be easily adapted to a real environment increasing the user independence at home.