The physico-chemical surface design of implants influences the surrounding cells. Osteoblasts on sharp-edged micro-topographies revealed an impaired cell phenotype, function and Ca2+ mobilization. The influence of edges and ridges on the Wnt/β-catenin pathway in combination with the cells’ stress response has not been clear. Therefore, MG-63 osteoblasts were studied on defined titanium-coated micro-pillars (5 × 5 × 5 µm) in vitro and in silico. MG-63s on micro-pillars indicated an activated state of the Wnt/β-catenin pathway. The β-catenin protein accumulated in the cytosol and translocated into the nucleus. Gene profiling indicated an antagonism mechanism of the transcriptional activity of β-catenin due to an increased expression of inhibitors like ICAT (inhibitor of β-catenin and transcription factor-4). Cells on pillars produced a significant reactive oxygen species (ROS) amount after 1 and 24 h. In silico analyses provided a detailed view on how transcriptional activity of Wnt signaling is coordinated in response to the oxidative stress induced by the micro-topography. Based on a coordinated expression of regulatory elements of the Wnt/β-catenin pathway, MG-63s are able to cope with an increased accumulation of β-catenin on micro-pillars and suppress an unintended target gene expression. Further, β-catenin may be diverted into other signaling pathways to support defense mechanisms against ROS.
Medical device-related infections are becoming a steadily increasing challenge for the health care system regarding the difficulties in the clinical treatment. In particular, cardiovascular implant infections, catheter-related infections, as well as infective endocarditis are associated with high morbidity and mortality risks for the patients. Antimicrobial materials may help to prevent medical device-associated infections and supplement the currently available therapies. In this study, we present an easy-to-handle and simplified in vivo model to test antimicrobial materials in the bloodstream of mice. The model system is composed of the implantation of a bacteria-laden micro-stent scaffold into the murine tail vein. Our model enables the simulation of catheter-related infections as well as the development of infective endocarditis specific pathologies in combination with material testing. Furthermore, this in vivo model can cover two phases of the biofilm formation, including both the local tissue response to the bacterial biofilm and the systemic inflammatory response against circulating bacteria in the bloodstream that detached from a mature biofilm.