Sabine ILLNER

Dr. Sabine ILLNER

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 October 2022 in PLOS ONE
Verified
Journal Article
Open access
PDF file
JHJennifer Huling
Jennifer Huling
AGAndreas Götz
Andreas Götz
NGNiels Grabow
Niels Grabow
SISabine ILLNER
Sabine ILLNER
This paper details the development and testing of the GIFT macro, which is a freely available program for ImageJ for the automated measurement of fiber diameters in SEM images of electrospun materials. The GIFT macro applies a validated method which distinguishes fiber diameters based on distance frequencies within an image. In this work, we introduce an applied version of the GIFT method which has been designed to be user-friendly while still allowing complete control over the various parameters involved in the image processing steps. The macro quickly processes large data sets and creates results that are reproducible and accurate. The program outputs both raw data and fiber diameter averages, so that the user can quickly assess the results and has the opportunity for further analysis if desired. The GIFT macro was compared directly to other software designed for fiber diameter measurements and was found to have comparable or lower average error, especially when measuring very small fibers, and reduced processing times per image. The macro, detailed instructions for use, and sample images are freely available online (https://github.com/IBMTRostock/GIFT). We believe that the GIFT macro is a valuable new tool for researchers looking to quickly, easily and reliably assess fiber diameters in electrospun materials.

9 March 2022 in Materials
Verified
Journal Article
Open access
PDF file
CMClaudia Matschegewski
Claudia Matschegewski
SKStefanie Kohse
Stefanie Kohse
JMJana Markhoff
Jana Markhoff
MTMichael Teske
Michael Teske
KWKatharina Wulf
Katharina Wulf
SISabine ILLNER
Sabine ILLNER
Nanofiber nonwovens are highly promising to serve as biomimetic scaffolds for pioneering cardiac implants such as drug-eluting stent systems or heart valve prosthetics. For successful implant integration, rapid and homogeneous endothelialization is of utmost importance as it forms a hemocompatible surface. This study aims at physicochemical and biological evaluation of various electrospun polymer scaffolds, made of FDA approved medical-grade plastics. Human endothelial cells (EA.hy926) were examined for cell attachment, morphology, viability, as well as actin and PECAM 1 expression. The appraisal of the untreated poly-L-lactide (PLLA L210), poly-ε-caprolactone (PCL) and polyamide-6 (PA-6) nonwovens shows that the hydrophilicity (water contact angle > 80°) and surface free energy (<60 mN/m) is mostly insufficient for rapid cell colonization. Therefore, modification of the surface tension of nonpolar polymer scaffolds by plasma energy was initiated, leading to more than 60% increased wettability and improved colonization. Additionally, NH3-plasma surface functionalization resulted in a more physiological localization of cell–cell contact markers, promoting endothelialization on all polymeric surfaces, while fiber diameter remained unaltered. Our data indicates that hydrophobic nonwovens are often insufficient to mimic the native extracellular matrix but also that they can be easily adapted by targeted post-processing steps such as plasma treatment. The results achieved increase the understanding of cell–implant interactions of nanostructured polymer-based biomaterial surfaces in blood contact while also advocating for plasma technology to increase the surface energy of nonpolar biostable, as well as biodegradable polymer scaffolds. Thus, we highlight the potential of plasma-activated electrospun polymer scaffolds for the development of advanced cardiac implants.

1 September 2016 in Current Directions in Biomedical Engineering
Verified
Journal Article
Open access
PDF file
SPSylvia Pfensig
Sylvia Pfensig
DADaniela Arbeiter
Daniela Arbeiter
KSKlaus-Peter Schmitz
Klaus-Peter Schmitz
NGNiels Grabow
Niels Grabow
TEThomas Eickner
Thomas Eickner
SISabine ILLNER
Sabine ILLNER
In this study, varying amounts of NIPAAm and an ionic liquid (IL), namely 1-vinyl-3-isopropylimidazolium bromide ([ViPrIm]+[Br]−), have been used to synthesize hybrid hydrogels by radical emulsion polymerization. Amounts of 70/30%, 50/50%, 30/70%, 15/85% and 5/95% (wt/wt) of PIL/pNIPAAm were used to produce hybrid hydrogels as well as the parental hydrogels. The adhesive strength was investigated and evaluated for mechanical characterization. Thermal properties of resulting hydrogels have been investigated using differential scanning calorimetry (DSC) in a default heating temperature range (heating rate 10 K min−1). The presence of poly ionic liquids (PIL) in the polymer matrix leads to a moved LCST (lower critical solution temperature) to a higher temperature range for certain hybrid hydrogels PIL/pNIPAAm. While pNIPAAm exhibits an LCST at 33.9 ± 0.3°C, PIL/pNIPAAm 5/95% and PIL/pNIPAAm 15/85% were found to have LCSTs at 37.6 ± 0.9°C and 52 ± 2°C, respectively. This could be used for controlled drug release that goes along with increasing body temperature in response to an implantation caused infection

13 October 2021 in Biomedicines
Verified
Journal Article
Open access
PDF file
CMCaroline Moerke
Caroline Moerke
MKMarlen Kloss
Marlen Kloss
KWKatharina Wulf
Katharina Wulf
SISabine ILLNER
Sabine ILLNER
SKSabine Kischkel
Sabine Kischkel
HIHuseyin Ince
Huseyin Ince
Medical device-related infections are becoming a steadily increasing challenge for the health care system regarding the difficulties in the clinical treatment. In particular, cardiovascular implant infections, catheter-related infections, as well as infective endocarditis are associated with high morbidity and mortality risks for the patients. Antimicrobial materials may help to prevent medical device-associated infections and supplement the currently available therapies. In this study, we present an easy-to-handle and simplified in vivo model to test antimicrobial materials in the bloodstream of mice. The model system is composed of the implantation of a bacteria-laden micro-stent scaffold into the murine tail vein. Our model enables the simulation of catheter-related infections as well as the development of infective endocarditis specific pathologies in combination with material testing. Furthermore, this in vivo model can cover two phases of the biofilm formation, including both the local tissue response to the bacterial biofilm and the systemic inflammatory response against circulating bacteria in the bloodstream that detached from a mature biofilm.

9 February 2023 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
AGAndreas Götz
Andreas Götz
VSVolkmar Senz
Volkmar Senz
WSWolfram Schmidt
Wolfram Schmidt
DKDaniela Koper
Daniela Koper
NGNiels Grabow
Niels Grabow
SISabine ILLNER
Sabine ILLNER

1 September 2017 in Current Directions in Biomedical Engineering
Verified
Journal Article
Open access
PDF file
ABAndreas Brietzke
Andreas Brietzke
CEChristian von der Ehe
Christian von der Ehe
SISabine ILLNER
Sabine ILLNER
CMClaudia Matschegewski
Claudia Matschegewski
NGNiels Grabow
Niels Grabow
Udo  KraglUdo Kragl
Udo Kragl
For the development of intelligent implant systems hydrogels (HG) from crosslinked ionic liquids feature a high potential to be utilised as a drug depot. Biocompatibility of the HGs is one key prerequisite for biomedical applications. HGs were polymerised from a variety of different ionic monomers based on methacrylate, methacrylamide, styrene or vinyl imidazolium derivatives in aqueous solution. N,N'-methylenebisacrylamide was used as crosslinker. CellQuanti-Blue™ Cell Viability Assay Kit was implemented to proof viability of L929 mouse fibroblasts. The predominant part of the HG eluates generated only a marginal reduction of less than 15% cell viability at 100% eluate concentration. This underlines the excellent suitability of these HGs for biomedical applications and revealed some promising candidates for the development of drug depots for implants.