This review provides a comparative analysis of the performance, toxicity, environmental impact, and health risks associated with fluorotelomer-based/short-chain AFFF and F3. Despite notable progress in F3 development, achieving comparable performance remains challenging in some cases. F3 formulations, while promising, are yet to be considered a direct replacement for AFFF in all Class B fire suppression scenarios due to variations in their performance across different fuel types and test conditions. Available studies indicate that commercially available F3 exhibit greater biodegradability and reduced environmental persistence compared to AFFF. However, some alternatives may still pose similar environmental impacts. Limited ecotoxicity studies suggest that some F3 may exhibit equal or even higher toxicity to aquatic species than short-chain (C6) AFFF. Toxicological assessments and risk evaluations of F3 should consider factors beyond environmental persistence, including acute and chronic ecotoxicity, potential endocrine disruption, and the full toxicological profile of foam formulations and their individual components. Further research is necessary to understand the fate, transport, bioaccumulation, and toxicity of F3 degradation products. Addressing these knowledge gaps is crucial to ensure the safe and sustainable implementation of F3 as an alternative fire suppression solution.
Poly(ε-caprolactone) (PCL) is a hydrophobic, resorbable aliphatic polymer recognized for its low tenacity and extensive elongation at break, making it a popular choice for fabricating biodegradable tissue engineering scaffolds. PCL’s slow degradation rate typically results in a complete resorption period of 2 to 3 years. While numerous studies have examined the degradation of PCL in various forms such as films and webs, no study to date has investigated its physiological degradation in multifilament yarn form. In this study, we subjected PCL multifilament yarn samples to physiological conditions in phosphate-buffered saline (PBS) maintained at a consistent temperature of 37 ± 2 °C and agitated at 45 rpm for a period of 32 weeks. We retrieved samples at five different intervals to analyze the degradation profile of the multifilament yarn. This allowed us to estimate the complete resorption time and rate under these in vitro conditions. Over the 32-week period, the multifilament yarn’s mass decreased by 4.8%, its elongation at break declined by 42%, the tenacity dropped by 40%, and the peak load at break fell by 46.5%. Based on these findings, we predict that a scaffold structure incorporating PCL multifilament yarn would undergo complete resorption in approximately 14 months under physiological conditions, such as in PBS solution at a pH of approximately 7 and a temperature of 37 °C.
30 November 2023 in Journal of Industrial Textiles
In 2022, the occupation of firefighting was categorized as a “Group 1” carcinogen, meaning it is known to be carcinogenic to humans. The personal protective equipment that structural firefighters wear is designed to safeguard them from thermal, physical, and chemical hazards while maintaining thermo-physiological comfort. Typically, the outer layer of structural turnout gear is finished with a durable water and oil-repellent (DWR) based on per- and polyfluoroalkyl substances (PFAS) that helps limit exposure to water and hazardous liquids. The PFAS-based aqueous emulsion typically used in DWR finishes is highly persistent and can cause various health problems if absorbed into the body through ingestion, inhalation, and/or dermal absorption. In response, the U.S. Fire Service has begun using non-PFAS water repellants in firefighter turnout gear. This study aims to evaluate the performance of both traditional PFAS-based and alternative non-PFAS outer shell materials. The study involved exposing both PFAS-based and non-PFAS DWR outer shell materials in turnout composites to simulated job exposures (i.e., weathering, thermal exposure, and laundering) that artificially aged the materials. After exposures, samples were evaluated for repellency, durability, thermal protection, and surface chemistry analysis to determine any potential performance trade-offs that may exist. Non-PFAS outer shell fabrics were found not to be diesel/oil-repellent, posing a potential flammability hazard if exposed to diesel and subsequent flame on an emergency response. Both PFAS-based and non-PFAS sets of fabrics performed similarly in terms of thermal protective performance, tearing strength, and water repellency. The surface analysis suggests that both PFAS and non-PFAS chemistries can degrade and shed from fabrics during the aging process. The study indicates that firefighters should be educated and trained regarding the potential performance trade-offs, such as oil absorption and flammability concerns when transitioning to non-PFAS outer shell materials.
Firefighters are exposed to several potentially carcinogenic fireground contaminants. The current NFPA 1851 washing procedures are less effective in cleaning due to the limited intensity of the washing conditions that are used. The 2020 edition of NFPA 1851 has added limited specialized cleaning for higher efficacy. The liquid carbon dioxide (CO2) laundering technique has gained popularity in recent years due to its availability to remove contaminants and its eco-friendliness. The primary aim of this study is to address the firefighter questions regarding the efficacy of cleaning with liquid CO2 and to compare it with the conventional washing technique. The unused turnout jackets were contaminated with a mixture of fireground contaminants. These turnout jackets were cleaned with conventional NFPA 1851-appoved aqueous washing and a commercially available liquid CO2 method. Post-cleaning samples were analyzed for contamination using pressurized solvent extraction and GC-MS. The liquid CO2 technique demonstrated considerable improvement in washing efficiency compared to the conventional washing.
The National Fire Protection Association (NFPA) 1851 document provides guidelines for firefighters on the care and maintenance of their PPE, including decontamination practices. Firefighters are exposed to various toxic chemicals during fire suppression activities, making effective decontamination crucial for their safety. This study evaluated the efficacy of different washing parameters, including temperature, time, and surfactants, on cleaning outer-shell material contaminated with nine targeted compounds from three different functional groups: phenols, polycyclic aromatic hydrocarbons (PAHs), and phthalates. The study was conducted on both bench-scale and full-scale levels, with contaminated swatches washed in a water shaker bath in the bench-scale evaluation and full-sized washer extractors used in the full-scale evaluation. The results showed that bench-scale washing demonstrated similar trends in contaminant removal to full-scale washing. Importantly, the study highlighted the complexity of removing fireground contaminants from the personal protective ensemble (PPE). The findings of this study have practical implications for the firefighting industry as they provide insight into the effectiveness of different washing parameters for PPE decontamination. Future studies could explore the impact of repeated washing on PPE and investigate the potential for developing more efficient decontamination strategies. Ultimately, the study underscores the importance of ongoing efforts to ensure the safety of firefighters, who face significant occupational hazards.
The concern for firefighters’ occupational exposure to harmful contaminants is growing due to the increase in health issues in the firefighting community. At such times, effective decontamination of personnel and equipment is an essential component of a hazard mitigation strategy. The current decontamination practices used for firefighter protective clothing have been shown to not be very effective. Hence, the scientific community is looking for several alternatives to conventional washing procedures. Liquid carbon dioxide (CO2) has been used in laundering and has distinct advantages over conventional dry-cleaning solvents such as perchloroethylene. The following study is aimed to assess how different washing procedures affect the durability of the turnout material. The study includes using three washing procedures on different samples: 1) conventional washing procedure, 2) liquid CO2 washing procedure, and 3) a high-temperature washing procedure. Samples for durability testing were constructed from a common aramid fabric used in firefighter turnout ensembles. These swatches were subjected to different washing techniques. The durability assessment was performed for physical testing of the samples, visual inspection, water repellency, and quantifying color changes using spectrophotometric analysis. The conventional wash and high-temperature washing affected the durability of the outer shell material in a significant manner. The liquid CO2 process did not affect the samples’ water repellency or physical strength. In contrast, conventional and high-temperature washing significantly affected the durability of the outer shell material. However, all samples met the criteria for tearing strength outlined in the NFPA 1971 standard subsection 7.1.11.