Kyra Stull

Dr. Kyra Stull

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2014 in Forensic Science International
Verified
Journal Article
Closed access
KSKyra Stull
Kyra Stull
MTMeredith L. Tise
Meredith L. Tise
ZAZabiullah Ali
Zabiullah Ali
DFDavid R. Fowler
David R. Fowler

8 November 2016 in International journal of legal medicine
Verified
Journal Article
Closed access
PDF file
GKGabriele C. Krüger
Gabriele C. Krüger
Ericka Noelle L'AbbéEricka Noelle L'Abbé
Ericka Noelle L'Abbé
KSKyra Stull
Kyra Stull

1 November 2019 in Forensic Science International
Verified
Journal Article
Closed access
KCKerri L. Colman
Kerri L. Colman
HBHans H. de Boer
Hans H. de Boer
JDJohannes GG Dobbe
Johannes GG Dobbe
NLNiels P.T.J. Liberton
Niels P.T.J. Liberton
KSKyra Stull
Kyra Stull
AMAlie E. van der Merwe
Alie E. van der Merwe

10 February 2017 in International journal of legal medicine
Verified
Journal Article
Open access
PDF file
KCKerri L. Colman
Kerri L. Colman
JDJohannes GG Dobbe
Johannes GG Dobbe
KSKyra Stull
Kyra Stull
JRJan M. Ruijter
Jan M. Ruijter
RORoelof-Jan Oostra
Roelof-Jan Oostra
GSGeert J. Streekstra
Geert J. Streekstra
Almost all European countries lack contemporary skeletal collections for the development and validation of forensic anthropological methods. Furthermore, legal, ethical and practical considerations hinder the development of skeletal collections. A virtual skeletal database derived from clinical computed tomography (CT) scans provides a potential solution. However, clinical CT scans are typically generated with varying settings. This study investigates the effects of image segmentation and varying imaging conditions on the precision of virtual modelled pelves. An adult human cadaver was scanned using varying imaging conditions, such as scanner type and standard patient scanning protocol, slice thickness and exposure level. The pelvis was segmented from the various CT images resulting in virtually modelled pelves. The precision of the virtual modelling was determined per polygon mesh point. The fraction of mesh points resulting in point-to-point distance variations of 2 mm or less (95% confidence interval (CI)) was reported. Colour mapping was used to visualise modelling variability. At almost all (>97%) locations across the pelvis, the point-to-point distance variation is less than 2 mm (CI = 95%). In >91% of the locations, the point-to-point distance variation was less than 1 mm (CI = 95%). This indicates that the geometric variability of the virtual pelvis as a result of segmentation and imaging conditions rarely exceeds the generally accepted linear error of 2 mm. Colour mapping shows that areas with large variability are predominantly joint surfaces. Therefore, results indicate that segmented bone elements from patient-derived CT scans are a sufficiently precise source for creating a virtual skeletal database.

1 December 2014 in Forensic Science International
Verified
Journal Article
Closed access
KSKyra Stull
Kyra Stull
MKMichael W. Kenyhercz
Michael W. Kenyhercz
Ericka Noelle L'AbbéEricka Noelle L'Abbé
Ericka Noelle L'Abbé

1 August 2017 in Forensic Science International
Verified
Journal Article
Closed access
MKMichael W. Kenyhercz
Michael W. Kenyhercz
AKAlexandra R. Klales
Alexandra R. Klales
KSKyra Stull
Kyra Stull
KMKyle A. McCormick
Kyle A. McCormick
SCStephanie J. Cole
Stephanie J. Cole