In this article, a minimum-copper-loss fault-tolerant control scheme is proposed for open-phase fault and open-switch fault of dual three-phase permanent magnet synchronous motor (DT-PMSM) drives. Both the winding configurations of isolated neutral points and connected neutral points are studied in this article. In conventional minimum-copper-loss fault-tolerant control schemes, the constraints of sinusoidal phase currents result in insufficient copper-loss reduction. Different from them, the current references with the theoretically lowest copper losses are first derived and applied for different fault cases of DT-PMSM drives without using any unnecessary constraints in the proposed fault-tolerant control scheme. Thus, all phase currents in the proposed minimum-copper-loss fault-tolerant control scheme are optimized to be nonsinusoidal waveforms. Besides, the copper losses are further reduced by fully utilizing the remaining healthy switch in the faulty inverter leg for the open-switch fault of DT-PMSM drives with the proposed scheme. It has been theoretically and experimentally proved that the proposed fault-tolerant control scheme can reduce copper losses than all existing fault-tolerant schemes for both open-phase fault and open-switch fault in typical two-level voltage-source-inverter-fed DT-PMSM drives.
10 July 2020 in IEEE Transactions on Industrial Electronics
Conventional buck power factor correction (PFC) converter has the disadvantage of high harmonic currents, which limits its applications. In this paper, a buck type single-switch integrated PFC converter is presented and analyzed. It is composed of buck and flyback PFC converters by using only one active switch, which benefits from simple control. The buck and flyback PFC converters are input-parallel and output-parallel connected. With critical conduction mode (CRM) constant on time (COT) control, the effect of dead zone of buck input current is eliminated by flyback unit. Therefore, the input harmonic currents of the proposed converters can easily meet IEC61000-3-2 Class C limits. With the advantages of buck and flyback PFC converters, the proposed converter can achieve high efficiency and low total harmonic distortion (THD) in universal-input applications. Simplified steady-state analysis and design considerations are introduced in this paper. Finally, a 96W prototype with 94.5% peak efficiency is built to verify the analysis results.
4 February 2020 in IEEE Transactions on Applied Superconductivity
An experimental platform of high temperature superconducting (HTS) synchronous motor with HTS flux pump has been designed and under construction. The HTS flux pump as an exciter eliminates thermal load from the metal current leads, which will reduce the cryogenic volume and improve the efficiency of the HTS machine. A finite element model (FEM) using T-A formulation was developed to analyze the electromagnetic characteristics of a double-pancake (DP) racetrack coil. The no-insulation (NI) racetrack coil wound by YBCO tapes was fabricated with a winding machine in our lab. We proposed a novel mechanical structure to avoid the impregnation of epoxy resin and make the coil more reliable. The turn-to-turn pressure of the racetrack coil can be changed by driving the screws on the straight section. Besides, we manufactured a rotating HTS flux pump as a DC power supply to charge the racetrack coil without contact. The self-field critical current test with a direct current (DC) power supply and the charging experiment with the HTS flux pump of the constructed YBCO racetrack coil were performed at 77 K.
8 March 2019 in IEEE Transactions on Applied Superconductivity
This paper presents an electromagnetic design of a 1.5 T REBCO magnet for dedicated orthopedic magnetic reso-nance imaging (MRI). This design makes MRI portable as well as cheaper. Due to the application of no-insulation (NI) high tem-perature superconductor (HTS) technology, the magnet com-posed of double-pancake coils (DPC) is highly compact; its outer diameter and axial length are both less than 300 mm, diameter of room-temperature bore of the magnet is 200 mm. On the other hand, we used multi-flux pumps to charge the DPCs separately to reduce tape consumption and costs of power sources. In our op-timized magnet, four HTS flux pumps were designed to charge the MRI magnet, while the overall tape consumption was de-creased by 29.7% compared to that charged by a single DC cur-rent source. This multiple DC current sources method avoids the current limiting effect of the DPCs located at the end of the mag-net, which has the highest field normal to the surface of the 2G HTS wire. Moreover, by using the HTS flux pump, the current leads which cause heat leakage were eliminated, while the HTS magnet was operated in a persistent mode, with its decayed cur-rent been constantly fed by the HTS flux pump. Although the whole cost is not able to compete with LTS MRI, high-field port-able MRI are in great demand.
6 January 2023 in IEEE Transactions on Power Electronics
Bipolarity in dc microgrids is desirable as it enhances the system's reliability and efficiency. However, the stability assessment for a bipolar dc microgrid is challenging due to the integration of a three-wire dc distribution line and numerous connected power converters, which is different from the stability analysis of a conventional unipolar dc microgrid. In this article, the basic form is arranged by a generalized voltage source or current source, and the simplified form is derived by looking into the different bus ports of a bipolar system in detail. Then, an impedance sum criteria-based stability conditions of different bus ports in the bipolar dc microgrid are proposed. To explore the mutual influence of the stability among different bus ports and investigate the stability issues caused by unbalanced loads connected to the symmetrical bus port, three cases are studied: 1) ± V dc bus ports are connected with balanced and unbalanced loads; 2) − V dc bus port introduces the photovoltaic unit and the energy storage unit; and 3) the 2 V dc bus port introduces the photovoltaic unit and the energy storage unit. Finally, a ±24 V bipolar dc microgrid platform is set up to conduct experiments, verifying the accuracy and effectiveness of the stability evaluation method.
20 September 2019 in IEEE Transactions on Power Electronics
An integrated buck-boost-buck-type single-switch multistring resonant light-emitting diode (LED) driver is proposed and analyzed. It combines buck-boost and buck converters to achieve passive current balancing and power factor correction. With this circuit configuration, the proposed LED driver employs only one low-side connection active switch, resulting in a very simple control requirement involving one closed-loop controller for regulating one output current. Other output currents can be balanced automatically by resonant capacitor and storage capacitors, making the control strategy economical. In addition, high efficiency is achieved due to single-stage power conversion. Taking three-string LED driver as an example, the proposed buck-boost-buck-type single-switch LED driver is studied in terms of operating principle, current balancing principle, power factor (PF) analysis, voltage gain, and key circuit parameter design. Finally, an 84-W high-PF three-string LED driver prototype with 94.3% peak efficiency is built to verify the analytical results.