Jürgen Weisser

Dr. Jürgen Weisser

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 January 2020 in Cells
Verified
Journal Article
Open access
PDF file
Valentina RussoValentina Russo
Valentina Russo
Mohammad El KhatibMohammad El Khatib
Mohammad El Khatib
LMLisa Di Marcantonio
Lisa Di Marcantonio
MAMassimo Ancora
Massimo Ancora
RWRalf Wyrwa
Ralf Wyrwa
Barbara BarboniBarbara Barboni
Barbara Barboni
Background. The design of tendon biomimetic electrospun fleece with Amniotic Epithelial Stem Cells (AECs) that have shown a high tenogenic attitude may represent an alternative strategy to overcome the unsatisfactory results of conventional treatments in tendon regeneration. Methods. In this study, we evaluated AEC-engineered electrospun poly(lactide-co-glycolide) (PLGA) fleeces with highly aligned fibers (ha-PLGA) that mimic tendon extracellular matrix, their biocompatibility, and differentiation towards the tenogenic lineage. PLGA fleeces with randomly distributed fibers (rd-PLGA) were generated as control. Results. Optimal cell infiltration and biocompatibility with both PLGA fleeces were shown. However, only ha-PLGA fleeces committed AECs towards an Epithelial-Mesenchymal Transition (EMT) after 48 h culture, inducing their cellular elongation along the fibers’ axis and the upregulation of mesenchymal markers. AECs further differentiated towards tenogenic lineage as confirmed by the up-regulation of tendon-related genes and Collagen Type 1 (COL1) protein expression that, after 28 days culture, appeared extracellularly distributed along the direction of ha-PLGA fibers. Moreover, long-term co-cultures of AEC-ha-PLGA bio-hybrids with fetal tendon explants significantly accelerated of half time AEC tenogenic differentiation compared to ha-PLGA fleeces cultured only with AECs. Conclusions. The fabricated tendon biomimetic ha-PLGA fleeces induce AEC tenogenesis through an early EMT, providing a potential tendon substitute for tendon engineering research.

15 September 2021 in Molecules
Verified
Journal Article
Open access
PDF file
AWAnnika Wartenberg
Annika Wartenberg
JWJürgen Weisser
Jürgen Weisser
Matthias SchnabelrauchMatthias Schnabelrauch
Matthias Schnabelrauch
Cryogels are a class of macroporous, interconnective hydrogels polymerized at sub-zero temperatures forming mechanically robust, elastic networks. In this review, latest advances of cryogels containing mainly glycosaminoglycans (GAGs) or composites of GAGs and other natural or synthetic polymers are presented. Cryogels produced in this way correspond to the native extracellular matrix (ECM) in terms of both composition and molecular structure. Due to their specific structural feature and in addition to an excellent biocompatibility, GAG-based cryogels have several advantages over traditional GAG-hydrogels. This includes macroporous, interconnective pore structure, robust, elastic, and shape-memory-like mechanical behavior, as well as injectability for many GAG-based cryogels. After addressing the cryogelation process, the fabrication of GAG-based cryogels and known principles of GAG monomer crosslinking are discussed. Finally, an overview of specific GAG-based cryogels in biomedicine, mainly as polymeric scaffold material in tissue regeneration and tissue engineering-related controlled release of bioactive molecules and cells, is provided.

1 September 2017 in Materials Science and Engineering: C
Verified
Journal Article
Closed access
TLThorsten Laube
Thorsten Laube
JWJürgen Weisser
Jürgen Weisser
SBStefan Berger
Stefan Berger
SBStefan Börner
Stefan Börner
SBSabine Bischoff
Sabine Bischoff
Matthias SchnabelrauchMatthias Schnabelrauch
Matthias Schnabelrauch

11 February 2022 in Nanomaterials
Verified
Journal Article
Open access
PDF file
TLThorsten Laube
Thorsten Laube
JWJürgen Weisser
Jürgen Weisser
SSSvea Sachse
Svea Sachse
TSThomas Seemann
Thomas Seemann
RWRalf Wyrwa
Ralf Wyrwa
Matthias SchnabelrauchMatthias Schnabelrauch
Matthias Schnabelrauch
The antibacterial activity of different antibiotic and metal-free thin polymer coatings was investigated. The films comprised quaternary ammonium compounds (QAC) based on a vinyl benzyl chloride (VBC) building block. Two monomeric QAC of different alkyl chain lengths were prepared, and then polymerized by two different polymerization processes to apply them onto Ti surfaces. At first, the polymeric layer was generated directly on the surface by atom transfer radical polymerization (ATRP). For comparison purposes, in a classical route a copolymerization of the QAC-containing monomers with a metal adhesion mediating phosphonate (VBPOH) monomers was carried out and the Ti surfaces were coated via drop coating. The different coatings were characterized by X-ray photoelectron spectroscopy (XPS) illustrating a thickness in the nanomolecular range. The cytocompatibility in vitro was confirmed by both live/dead and WST-1 assay. The antimicrobial activity was evaluated by two different assays (CFU and BTG, resp.,), showing for both coating processes similar results to kill bacteria on contact. These antibacterial coatings present a simple method to protect metallic devices against microbial contamination.

1 January 2014 in BioNanoMaterials
Verified
Journal Article
Closed access
LTLoredana Tammaro
Loredana Tammaro
VVVittoria Vittoria
Vittoria Vittoria
RWRalf Wyrwa
Ralf Wyrwa
JWJürgen Weisser
Jürgen Weisser
BBBirgitt Beer
Birgitt Beer
MSMatthias Schnabelrauch
Matthias Schnabelrauch
Non-woven hybrid meshes based on poly(l-lactide-co-d,l-lactide) (dl-PLA) and β-tricalcium phosphate (β-TCP) were fabricated and comprehensively characterized. Stock suspensions of β-TCP powder in dl-PLA acetone solutions were used for the electrospinning process. Structure, morphology and thermal properties of the electrospun samples were investigated by X-ray diffraction (XRD), scanning electron microscopy (SEM), thermogravimetric analysis (TGA) and differential scanning calorimetry (DSC). The electrospun hybrid materials show a micro-composite structure, and a morphology characterized by a three-dimensional porous fibrous mesh with randomly distributed fibers possessing average fiber diameters between 680 and 970 nm, uniform thickness along the fibers and beads structure only for higher β-TCP concentration electrospun samples. Both pure PLA and hybrid non-woven meshes exhibit a good thermal stability and a continuous degradation in simulated body fluid medium. A live/dead staining viability assay using MC3T3-E1 preosteoblasts reveals the excellent cytocompatibility of the fabricated non-wovens. Enhanced alkaline phosphatase (AP) activity of MC3T3-E1 cells during culture on the dl-PLA and the composite non-woven meshes demonstrates their potential for applications in hard tissue repair.

28 December 2020 in Molecules
Verified
Journal Article
Open access
PDF file
CRClaudia Rode
Claudia Rode
RWRalf Wyrwa
Ralf Wyrwa
JWJürgen Weisser
Jürgen Weisser
Matthias SchnabelrauchMatthias Schnabelrauch
Matthias Schnabelrauch
MVMarijan Vucak
Marijan Vucak
RLRainer Lutz
Rainer Lutz
Polyurethanes have the potential to impart cell-relevant properties like excellent biocompatibility, high and interconnecting porosity and controlled degradability into biomaterials in a relatively simple way. In this context, a biodegradable composite material made of an isocyanate-terminated co-oligoester prepolymer and precipitated calcium carbonated spherulites (up to 60% w/w) was synthesized and investigated with regard to an application as bone substitute in dental and orthodontic application. After foaming the composite material, a predominantly interconnecting porous structure is obtained, which can be easily machined. The compressive strength of the foamed composites increases with raising calcium carbonate content and decreasing calcium carbonate particle size. When stored in an aqueous medium, there is a decrease in pressure stability of the composite, but this decrease is smaller the higher the proportion of the calcium carbonate component is. In vitro cytocompatibility studies of the foamed composites on MC3T3-E1 pre-osteoblasts revealed an excellent cytocompatibility. The in vitro degradation behaviour of foamed composite is characterised by a continuous loss of mass, which is slower with higher calcium carbonate contents. In a first pre-clinical pilot trial the foamed composite bone substitute material (fcm) was successfully evaluated in a model of vertical augmentation in an established animal model on the calvaria and on the lateral mandible of pigs.