Ralf Wyrwa

Dr. Ralf Wyrwa

orcid

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 October 2017 in Journal of the American Chemical Society
Verified
Journal Article
Open access
SASven H. C. Askes
Sven H. C. Askes
GRG. Upendar Reddy
G. Upendar Reddy
RWRalf Wyrwa
Ralf Wyrwa
SBSylvestre Bonnet
Sylvestre Bonnet
ASAlexander Schiller
Alexander Schiller
Applicability of phototherapeutic CO-releasing molecules (photoCORMs) is limited because they are activated by harmful and poorly tissue-penetrating near-ultraviolet light. Here, a strategy is demonstrated to activate classical photoCORM Mn2(CO)10 using red light (635 nm). By mixing in solution a triplet photosensitizer (PS) with the photoCORM and shining red light, energy transfer occurs from triplet excited-state 3PS* to a photolabile triplet state of Mn2(CO)10, which, like under near-UV irradiation, led to complete release of carbonyls. Crucially, such “triplet-sensitized CO-release” occurred in solid-state materials: when PS and Mn2(CO)10 were embedded in electrospun nonwoven fabrics, CO was liberated upon irradiation with low-intensity red light (≤36 mW 635 nm).

13 May 2020 in Cells
Verified
Journal Article
Open access
PDF file
Mohammad El KhatibMohammad El Khatib
Mohammad El Khatib
Annunziata MauroAnnunziata Mauro
Annunziata Mauro
MMMiriam Di Mattia
Miriam Di Mattia
RWRalf Wyrwa
Ralf Wyrwa
MSMartina Schweder
Martina Schweder
Valentina RussoValentina Russo
Valentina Russo
Injured tendons are challenging in their regeneration; thus, tissue engineering represents a promising solution. This research tests the hypothesis that the response of amniotic epithelial stem cells (AECs) can be modulated by fiber diameter size of tendon biomimetic fleeces. Particularly, the effect of electrospun poly(lactide-co-glycolide) (PLGA) fleeces with highly aligned microfibers possessing two different diameter sizes (1.27 and 2.5 µm: ha1- and ha2-PLGA, respectively) was tested on the ability of AECs to differentiate towards the tenogenic lineage by analyzing tendon related markers (Collagen type I: COL1 protein and mRNA Scleraxis: SCX, Tenomodulin: TNMD and COL1 gene expressions) and to modulate their immunomodulatory properties by investigating the pro- (IL-6 and IL-12) and anti- (IL-4 and IL-10) inflammatory cytokines. It was observed that fiber alignment and not fiber size influenced cell morphology determining the morphological change of AECs from cuboidal to fusiform tenocyte-like shape. Instead, fleece mechanical properties, cell proliferation, tenogenic differentiation, and immunomodulation were regulated by changing the ha-PLGA microfiber diameter size. Specifically, higher DNA quantity and better penetration within the fleece were found on ha2-PLGA, while ha1-PLGA fleeces with small fiber diameter size had better mechanical features and were more effective on AECs trans-differentiation towards the tenogenic lineage by significantly translating more efficiently SCX into the downstream effector TNMD. Moreover, the fiber diameter of 1.27 µm induced higher expression of pro-regenerative, anti-inflammatory interleukins mRNA expression (IL-4 and IL-10) with favorable IL-12/IL-10 ratio with respect to the fiber diameter of 2.5 µm. The obtained results demonstrate that fiber diameter is a key factor to be considered when designing tendon biomimetic fleece for tissue repair and provide new insights into the importance of controlling matrix parameters in enhancing cell differentiation and immunomodulation either for the cells functionalized within or for the transplanted host tissue.

27 January 2020 in Cells
Verified
Journal Article
Open access
PDF file
Valentina RussoValentina Russo
Valentina Russo
Mohammad El KhatibMohammad El Khatib
Mohammad El Khatib
LMLisa Di Marcantonio
Lisa Di Marcantonio
MAMassimo Ancora
Massimo Ancora
RWRalf Wyrwa
Ralf Wyrwa
Barbara BarboniBarbara Barboni
Barbara Barboni
Background. The design of tendon biomimetic electrospun fleece with Amniotic Epithelial Stem Cells (AECs) that have shown a high tenogenic attitude may represent an alternative strategy to overcome the unsatisfactory results of conventional treatments in tendon regeneration. Methods. In this study, we evaluated AEC-engineered electrospun poly(lactide-co-glycolide) (PLGA) fleeces with highly aligned fibers (ha-PLGA) that mimic tendon extracellular matrix, their biocompatibility, and differentiation towards the tenogenic lineage. PLGA fleeces with randomly distributed fibers (rd-PLGA) were generated as control. Results. Optimal cell infiltration and biocompatibility with both PLGA fleeces were shown. However, only ha-PLGA fleeces committed AECs towards an Epithelial-Mesenchymal Transition (EMT) after 48 h culture, inducing their cellular elongation along the fibers’ axis and the upregulation of mesenchymal markers. AECs further differentiated towards tenogenic lineage as confirmed by the up-regulation of tendon-related genes and Collagen Type 1 (COL1) protein expression that, after 28 days culture, appeared extracellularly distributed along the direction of ha-PLGA fibers. Moreover, long-term co-cultures of AEC-ha-PLGA bio-hybrids with fetal tendon explants significantly accelerated of half time AEC tenogenic differentiation compared to ha-PLGA fleeces cultured only with AECs. Conclusions. The fabricated tendon biomimetic ha-PLGA fleeces induce AEC tenogenesis through an early EMT, providing a potential tendon substitute for tendon engineering research.

28 February 2022 in Angewandte Chemie International Edition
Verified
Journal Article
Open access
PDF file
FPFlavio L. Portwich
Flavio L. Portwich
YCYves Carstensen
Yves Carstensen
ADAnindita Dasgupta
Anindita Dasgupta
Stephan KupferStephan Kupfer
Stephan Kupfer
RWRalf Wyrwa
Ralf Wyrwa
RKRobert Kretschmer
Robert Kretschmer
The high natural abundance of aluminium makes the respective fluorophores attractive for various optical applications, but photoluminescence quantum yields above 0.7 have yet not been reported for solutions of aluminium complexes. In this contribution, a dinuclear aluminium(III) complex featuring enhanced photoluminescence properties is described. Its facile one‐pot synthesis originates from a readily available precursor and trimethyl aluminium. In solution, the complex exhibits an unprecedented photoluminescence quantum yield near unity (Φabsolute 1.0±0.1) and an excited‐state lifetime of 2.3 ns. In the solid state, J‐aggregation and aggregation‐caused quenching are noted, but still quantum yields of 0.6 are observed. Embedding the complex in electrospun non‐woven fabrics yields a highly fluorescent fleece possessing a quantum yield of 0.9±0.04.

12 April 2019 in Chemistry – A European Journal
Verified
Journal Article
Closed access
PDF file
VRVadde Ramu
Vadde Ramu
GRGandra Upendar Reddy
Gandra Upendar Reddy
JLJingjing Liu
Jingjing Liu
PHPatrick Hoffmann
Patrick Hoffmann
RSRudrakant Sollapur
Rudrakant Sollapur
ASAlexander Schiller
Alexander Schiller

18 November 2021 in Cells
Verified
Journal Article
Open access
PDF file
Mohammad El KhatibMohammad El Khatib
Mohammad El Khatib
Valentina RussoValentina Russo
Valentina Russo
Giuseppe PrencipeGiuseppe Prencipe
Giuseppe Prencipe
Annunziata MauroAnnunziata Mauro
Annunziata Mauro
RWRalf Wyrwa
Ralf Wyrwa
Barbara BarboniBarbara Barboni
Barbara Barboni
Electrospun poly(lactic-co-glycolic acid) (PLGA) scaffolds with highly aligned fibers (ha-PLGA) represent promising materials in the field of tendon tissue engineering (TE) due to their characteristics in mimicking fibrous extracellular matrix (ECM) of tendon native tissue. Among these properties, scaffold biodegradability must be controlled allowing its replacement by a neo-formed native tendon tissue in a controlled manner. In this study, ha-PLGA were subjected to hydrolytic degradation up to 20 weeks, under di-H2O and PBS conditions according to ISO 10993-13:2010. These were then characterized for their physical, morphological, and mechanical features. In vitro cytotoxicity tests were conducted on ovine amniotic epithelial stem cells (oAECs), up to 7 days, to assess the effect of non-buffered and buffered PLGA by-products at different concentrations on cell viability and their stimuli on oAECs’ immunomodulatory properties. The ha-PLGA scaffolds degraded slowly as evidenced by a slight decrease in mass loss (14%) and average molecular weight (35%), with estimated degradation half-time of about 40 weeks under di-H2O. The ultrastructure morphology of the scaffolds showed no significant fiber degradation even after 20 weeks, but alteration of fiber alignment was already evident at week 1. Moreover, mechanical properties decreased throughout the degradation times under wet as well as dry PBS conditions. The influence of acid degradation media on oAECs was dose-dependent, with a considerable effect at 7 days’ culture point. This effect was notably reduced by using buffered media. To a certain level, cells were able to compensate the generated inflammation-like microenvironment by upregulating IL-10 gene expression and favoring an anti-inflammatory rather than pro-inflammatory response. These in vitro results are essential to better understand the degradation behavior of ha-PLGA in vivo and the effect of their degradation by-products on affecting cell performance. Indeed, buffering the degradation milieu could represent a promising strategy to balance scaffold degradation. These findings give good hope with reference to the in vivo condition characterized by physiological buffering systems.