The aim of this study was to compare the mortality rates, re-intervention rates, and volumetric changes in aortas following surgery, in terms of the true lumen and false lumen changes, using conventional hemi-arch repair (CET) and frozen elephant trunk (FET) techniques. During the period from 2015 to 2018, 66 patients underwent surgical treatment for acute aortic dissection (Debakey type 1). Demographic and procedure-related data were evaluated. We measured volumetric change before surgical treatment, at discharge, and at 12- and 24-month time points based on computed tomography angiography. The study cohort was divided into two groups (FET vs. CET). The mean age of the patients was 56.9 ± 9.4 years in the FET group versus 63.6 ± 11 years in the CET group (p = 0.063). The mean follow-up time was 24 ± 6 and 25 ± 5 months for the FET and CET groups, respectively. There were no significant differences between the two groups in terms of the medical histories of the cohorts. The results showed a significant increase in true lumen volume after the FET procedure (within 24 months postoperatively; p = 0.005), and no significant changes in total (p = 0.392) or false lumen (p = 0.659) volumes were noted. After the CET procedure, there were significant increases in total and false lumen volumes (p = 0.013, p = 0.042), while no significant change in true lumen was observed (p = 0.219). The volume increase in true lumen after the FET procedure was higher compared to the CET group at all postoperative time points (at discharge, 12 months, and 24 months) without significant evidence (p = 0.416, p = 0.422, p = 0.268). At two years, the volume increase in false lumen was significantly higher among the CET group compared to the FET group (p = 0.02). The Kaplan–Meier curve analysis showed that patients who underwent the CET procedure underwent significantly more re-interventions due to false lumen expansion of the descending aorta (p = 0.047). Present study results indicate that the true and false lumen changes in the aorta following the FET and CET procedures were different. FET led to a significant increase in true lumen volume, while false lumen volume remained stable; however, after the CET procedure, significant false lumen enlargement was noted at mid-term follow-up time points. The re-intervention rate after CET was higher due to false lumen expansion.
Background: The extent of aortic replacement for aneurysms of the distal ascending aorta remains controversial and opinions vary between standard cross-clamp resection and open hemiarch anastomosis in circulatory arrest and selective cerebral perfusion. As the deleterious effects of extended circulatory arrest are well-known, borderline indication for distal ascending aorta aneurysm repair must be outweighed against the potential risk of complications related to the open anastomosis. In the present study, we describe our own approach consisting of “transversal arch clamping” for exhaustive resection of aneurysms of the distal ascending aorta without open anastomosis and we present the postoperative outcomes. Methods: Between May 2017 and December 2019, 35 patients with aneurysm of the ascending aorta (20 male, 15 female) underwent replacement with repair of the lesser curvature without circulatory arrest. Pre-operative, intraoperative, and postoperative clinical outcomes were retrospectively withdrawn from our institutional database and analyzed. Results: Maximal diameter of distal ascending aorta was 47.5 mm. Patient median age was 66 years (IQR 14) (range 42–86). Preoperative logistic median EuroSCORE II was 17% (IQR 11.3). Median duration of cardiopulmonary bypass and cardiac arrest were 137 (IQR 64) and 93 (IQR 59) min, respectively. In-hospital and 30-day mortality were 0%. There were no cases with acute low output syndrome, surgical re-exploration for bleeding, kidney injury requiring dialysis, or wound infection. Disabling stroke was observed in one patient (2.9%). There was one case of major ventricular arrhythmia (2.9%). Conclusions: Our institutional experience suggests that this novel technique is safe and feasible. It facilitates complete resection of the aortic ascending aneurysm avoiding circulatory arrest, antegrade cerebral perfusion, additional peripheral cannulation, and all related complications.