Background: Coronary CT angiography (CCTA) may detect coronary artery disease (CAD) in transcatheter aortic valve implantation (TAVI) patients and may obviate invasive coronary angiography (ICA) in selected patients. We assessed the diagnostic accuracy of CCTA for detecting CAD in TAVI patients based on published data. Methods: Meta-analysis and meta-regression were performed based on a comprehensive electronic search, including relevant studies assessing the diagnostic accuracy of CCTA in the setting of TAVI patients compared to ICA. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV), were calculated on a patient and per segment level. Results: Overall, 27 studies (total of 7458 patients) were included. On the patient level, the CCTA’s pooled sensitivity and NPV were 95% (95% CI: 93–97%) and 97% (95% CI: 95–98%), respectively, while the specificity and PPV were at 73% (95% CI: 62–82%) and 64% (95% CI: 57–71%), respectively. On the segmental coronary vessel level, the sensitivity and NPV were 90% (95% CI: 79–96%) and 98% (95% CI: 97–99%). Conclusions: This meta-analysis highlights CCTA’s potential as a first-line diagnostic tool although its limited PPV and specificity may pose challenges when interpreting heavily calcified arteries. This study underscores the need for further research and protocol standardization in this area.
Background: Amiodarone has a profound adverse toxicity profile. Large population-based analyses quantifying the risk of thyroid dysfunction (TD) in adults with and without congenital heart disease (ACHD) are lacking. Methods: All adults registered with a major German health insurer (≈9.2 million members) with amiodarone prescriptions were analyzed. Occurrence of amiodarone-associated TD was assessed. Results: Overall, 48,891 non-ACHD (37% female; median 73 years) and 886 ACHD (34% female; median 66 years) received amiodarone. Over 184,787 patient-years, 10,875 cases of TD occurred. The 10-year risk for TD was 38% in non-ACHD (35% ACHD). Within ACHD, compared to amiodarone-naïve patients, the hazard ratio (HR) for TD was 3.9 at 4 years after any amiodarone exposure. TD was associated with female gender (HR 1.42, p < 0.001) and younger age (HR 0.97 per 10 years, p = 0.009). Patients with congenital heart disease were not at increased risk (HR 0.98, p = 0.80). Diagnosis of complex congenital heart disease, however, was a predictor for TD (HR 1.56, p = 0.02). Amiodarone was continued in 47% of non-ACHD (38% ACHD), and 2.3% of non-ACHD (3.5% ACHD) underwent thyroid surgery/radiotherapy. Conclusions: Amiodarone-associated TD is common and comparable in non-ACHD and ACHD. While female gender and younger age are predictors for TD, congenital heart disease is not necessarily associated with an elevated risk.
Background: The extent of aortic replacement for aneurysms of the distal ascending aorta remains controversial and opinions vary between standard cross-clamp resection and open hemiarch anastomosis in circulatory arrest and selective cerebral perfusion. As the deleterious effects of extended circulatory arrest are well-known, borderline indication for distal ascending aorta aneurysm repair must be outweighed against the potential risk of complications related to the open anastomosis. In the present study, we describe our own approach consisting of “transversal arch clamping” for exhaustive resection of aneurysms of the distal ascending aorta without open anastomosis and we present the postoperative outcomes. Methods: Between May 2017 and December 2019, 35 patients with aneurysm of the ascending aorta (20 male, 15 female) underwent replacement with repair of the lesser curvature without circulatory arrest. Pre-operative, intraoperative, and postoperative clinical outcomes were retrospectively withdrawn from our institutional database and analyzed. Results: Maximal diameter of distal ascending aorta was 47.5 mm. Patient median age was 66 years (IQR 14) (range 42–86). Preoperative logistic median EuroSCORE II was 17% (IQR 11.3). Median duration of cardiopulmonary bypass and cardiac arrest were 137 (IQR 64) and 93 (IQR 59) min, respectively. In-hospital and 30-day mortality were 0%. There were no cases with acute low output syndrome, surgical re-exploration for bleeding, kidney injury requiring dialysis, or wound infection. Disabling stroke was observed in one patient (2.9%). There was one case of major ventricular arrhythmia (2.9%). Conclusions: Our institutional experience suggests that this novel technique is safe and feasible. It facilitates complete resection of the aortic ascending aneurysm avoiding circulatory arrest, antegrade cerebral perfusion, additional peripheral cannulation, and all related complications.
Background/Objectives: Currently, the transfemoral approach is recognized as the primary method for accessing transcatheter aortic valve implantation (TAVI). However, alternative techniques are needed when the transfemoral access is not suitable. We proposed that a modified transaxillary approach through the distal left axillary artery is both viable and safe for conducting TAVI, potentially offering benefits for patients. Methods: From December 2018 to February 2024, a total of 24 patients (7 women, average age 77.9 ± 8 years) received TAVI using transaxillary access via the left axillary artery. The participants suffered from symptomatic severe aortic stenosis and were deemed TAVI candidates with iliofemoral anatomy unsuitable for a transfemoral route. The patient group displayed a high perioperative risk profile, with significant peripheral artery disease or severe obstructive infrarenal aortic conditions. The implantation of the aortic prosthesis was carried out through the left distal axillary artery. A balloon-expandable valve was used in every instance. Results: In the examined cohort, the 30-day mortality rate was 4.2%. A new pacemaker was necessary for four patients (16.7%). One case exhibited a new moderate neurological dysfunction. Additionally, one patient required surgical revision of the access point due to ischemia. Conclusions: Our findings indicate that transaxillary TAVI via the distal left axillary artery has yielded encouraging outcomes. This approach is practicable and safe, does not prolong the procedure, minimizes surgical trauma, ensures excellent access regardless of chest anatomy, and is sparing for the brachial plexus. As a single-center pilot study, our findings require confirmation in larger, prospective cohorts with extended follow-up to fully validate the safety and long-term efficacy of this technique.