Nor Syafirah Zambry

Dr. Nor Syafirah Zambry

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 September 2021 in Biosensors
Verified
Journal Article
Open access
PDF file
MAMohd Syafiq Awang
Mohd Syafiq Awang
YBYazmin Bustami
Yazmin Bustami
HHHairul Hisham Hamzah
Hairul Hisham Hamzah
NZNor Syafirah Zambry
Nor Syafirah Zambry
Mohamad Ahmad NajibMohamad Ahmad Najib
Mohamad Ahmad Najib
AAAbd Manaf Asrulnizam
Abd Manaf Asrulnizam
Large-scale food-borne outbreaks caused by Salmonella are rarely seen nowadays, thanks to the advanced nature of the medical system. However, small, localised outbreaks in certain regions still exist and could possess a huge threat to the public health if eradication measure is not initiated. This review discusses the progress of Salmonella detection approaches covering their basic principles, characteristics, applications, and performances. Conventional Salmonella detection is usually performed using a culture-based method, which is time-consuming, labour intensive, and unsuitable for on-site testing and high-throughput analysis. To date, there are many detection methods with a unique detection system available for Salmonella detection utilising immunological-based techniques, molecular-based techniques, mass spectrometry, spectroscopy, optical phenotyping, and biosensor methods. The electrochemical biosensor has growing interest in Salmonella detection mainly due to its excellent sensitivity, rapidity, and portability. The use of a highly specific bioreceptor, such as aptamers, and the application of nanomaterials are contributing factors to these excellent characteristics. Furthermore, insight on the types of biorecognition elements, the principles of electrochemical transduction elements, and the miniaturisation potential of electrochemical biosensors are discussed.

29 June 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
NZNor Syafirah Zambry
Nor Syafirah Zambry
GOGodwin Obande
Godwin Obande
MKMuhammad Fazli Khalid
Muhammad Fazli Khalid
YBYazmin Bustami
Yazmin Bustami
HHHairul Hisham Hamzah
Hairul Hisham Hamzah
AAAbd Manaf Asrulnizam
Abd Manaf Asrulnizam
The development of precise and efficient diagnostic tools enables early treatment and proper isolation of infected individuals, hence limiting the spread of coronavirus disease 2019 (COVID-19). The standard diagnostic tests used by healthcare workers to diagnose severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) infection have some limitations, including longer detection time, the need for qualified individuals, and the use of sophisticated bench-top equipment, which limit their use for rapid SARS-CoV-2 assessment. Advances in sensor technology have renewed the interest in electrochemical biosensors miniaturization, which provide improved diagnostic qualities such as rapid response, simplicity of operation, portability, and readiness for on-site screening of infection. This review gives a condensed overview of the current electrochemical sensing platform strategies for SARS-CoV-2 detection in clinical samples. The fundamentals of fabricating electrochemical biosensors, such as the chosen electrode materials, electrochemical transducing techniques, and sensitive biorecognition molecules, are thoroughly discussed in this paper. Furthermore, we summarised electrochemical biosensors detection strategies and their analytical performance on diverse clinical samples, including saliva, blood, and nasopharyngeal swab. Finally, we address the employment of miniaturized electrochemical biosensors integrated with microfluidic technology in viral electrochemical biosensors, emphasizing its potential for on-site diagnostics applications.

16 December 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
NZNor Syafirah Zambry
Nor Syafirah Zambry
Mohamad Ahmad NajibMohamad Ahmad Najib
Mohamad Ahmad Najib
MAMohd Syafiq Awang
Mohd Syafiq Awang
KSKasturi Selvam
Kasturi Selvam
MKMuhammad Fazli Khalid
Muhammad Fazli Khalid
IAIsmail Aziah
Ismail Aziah
The development of rapid, accurate, and efficient detection methods for Salmonella can significantly control the outbreak of salmonellosis that threatens global public health. Despite the high sensitivity and specificity of the microbiological, nucleic-acid, and immunological-based methods, they are impractical for detecting samples outside of the laboratory due to the requirement for skilled individuals and sophisticated bench-top equipment. Ideally, an electrochemical biosensor could overcome the limitations of these detection methods since it offers simplicity for the detection process, on-site quantitative analysis, rapid detection time, high sensitivity, and portability. The present scoping review aims to assess the current trends in electrochemical aptasensors to detect and quantify Salmonella. This review was conducted according to the latest Preferred Reporting Items for Systematic review and Meta-Analyses extension for Scoping Reviews (PRISMA-ScR) guidelines. A literature search was performed using aptamer and Salmonella keywords in three databases: PubMed, Scopus, and Springer. Studies on electrochemical aptasensors for detecting Salmonella published between January 2014 and January 2022 were retrieved. Of the 787 studies recorded in the search, 29 studies were screened for eligibility, and 15 studies that met the inclusion criteria were retrieved for this review. Information on the Salmonella serovars, targets, samples, sensor specification, platform technologies for fabrication, electrochemical detection methods, limit of detection (LoD), and detection time was discussed to evaluate the effectiveness and limitations of the developed electrochemical aptasensor platform for the detection of Salmonella. The reported electrochemical aptasensors were mainly developed to detect Salmonella enterica Typhimurium in chicken meat samples. Most of the developed electrochemical aptasensors were fabricated using conventional electrodes (13 studies) rather than screen-printed electrodes (SPEs) (two studies). The developed aptasensors showed LoD ranges from 550 CFU/mL to as low as 1 CFU/mL within 5 min to 240 min of detection time. The promising detection performance of the electrochemical aptasensor highlights its potential as an excellent alternative to the existing detection methods. Nonetheless, more research is required to determine the sensitivity and specificity of the electrochemical sensing platform for Salmonella detection, particularly in human clinical samples, to enable their future use in clinical practice.

13 September 2021 in Pathogens
Verified
Journal Article
Open access
PDF file
Mohamad Ahmad NajibMohamad Ahmad Najib
Mohamad Ahmad Najib
Khairul Mohd Fadzli MustaffaKhairul Mohd Fadzli Mustaffa
Khairul Mohd Fadzli Mustaffa
EOEugene Boon Beng Ong
Eugene Boon Beng Ong
KSKasturi Selvam
Kasturi Selvam
MKMuhammad Fazli Khalid
Muhammad Fazli Khalid
IAIsmail Aziah
Ismail Aziah
Typhoid fever, also known as typhoid, is a life-threatening bacterial infection that remains a global health concern. The infection is associated with a significant morbidity and mortality rate, resulting in an urgent need for specific and rapid detection tests to aid prevention and management of the disease. The present review aims to assess the specificity and sensitivity of the available literature on the immunodiagnostics of typhoid fever. A literature search was conducted using three databases (PubMed, ProQuest and Scopus) and manual searches through the references of identified full texts to retrieve relevant literature published between 1 January 2011 and 31 December 2020. Of the 577 studies identified in our search, 12 were included in further analysis. Lipopolysaccharides (LPS) and hemolysin E (HlyE) were the most frequently studied antigens. The specimens examined in these studies included serum and saliva. Using blood culture as the gold standard, anti-LPS IgA gave the highest sensitivity of 96% (95% CI: 93–99) and specificity of 96% (95% CI: 93–99) for distinguishing between typhoid cases and healthy controls, whereas the combination of anti-LPS and anti-flagellin total IgGAM gave the highest sensitivity of 93% (95% CI: 86–99) and specificity of 95% (95% CI: 89–100) for distinguishing typhoid cases and other febrile infections. A comparably high sensitivity of 92% (95% CI: 86–98) and specificity of 89% (95% CI: 78–100) were shown in testing based on detection of the combination of anti-LPS (IgA and IgM) and anti-HlyE IgG as well as a slightly lower sensitivity of 91% (95% CI: 74–100) in the case of anti-50kDa IgA. Anti-50kDa IgM had the lowest sensitivity of 36% (95% CI: 6–65) against both healthy and febrile controls. The development of a rapid diagnostic test targeting antibodies against lipopolysaccharides combined with flagellin appeared to be a suitable approach for the rapid detection test of typhoid fever. Saliva is added benefit for rapid typhoid diagnosis since it is less invasive. As a result, further studies could be done to develop additional approaches for adopting such samples.

7 January 2025 in IEEE Sensors Journal
Verified
Journal Article
Open access
LMLazar Milić
Lazar Milić
NZNor Syafirah Zambry
Nor Syafirah Zambry
FIFatimah Ibrahim
Fatimah Ibrahim
BPBojan Petrović
Bojan Petrović
SKSanja Kojić
Sanja Kojić
Goran M. StojanovicGoran M. Stojanovic
Goran M. Stojanovic
Flexible, screen-printed electrode systems offer significant advantages in biomedical applications due to their rapid fabrication capability and adaptability to irregular surfaces. Despite this, no flexible, screen-printed biosensors for pH measurement are readily available on the market. This paper introduces an innovative fabrication technique for integrating flexible screen-printed electrode (SPE) systems with multi-wall carbon nanotubes (MWCNTs). These SPE systems feature flexible screen-printed working electrodes functionalized with f-MWCNT for pH sensing, achieving a fabrication success rate of 78.57%. Furthermore, these SPE systems have been optimized to improve voltage changes and thoroughly characterized for performance using pH buffer solutions. This was done utilizing open-circuit potentiometry. The results demonstrate that the SPE systems can detect pH ranges from 4.0 to 8.9 with an average sensitivity of 33.66 mV/pH, an output range of 202.62 mV, a settling time of 19.71 s, and stability for up to 72 hours. Additionally, the SPE systems have been tested with artificial saliva within the pH range of 5.0 to 8.3, achieving a sensitivity of 44.86 mV/pH and an output range of 192.90 mV. These findings pave the way for further exploration in pH sensing research, particularly utilizing SPE systems coated with MWCNTs.

1 September 2024 in Biomicrofluidics
Verified
Journal Article
Open access
PDF file
LMLazar Milić
Lazar Milić
NZNor Syafirah Zambry
Nor Syafirah Zambry
FIFatimah Ibrahim
Fatimah Ibrahim
Bojan PetrovicBojan Petrovic
Bojan Petrovic
Sanja KojicSanja Kojic
Sanja Kojic
Goran M. StojanovicGoran M. Stojanovic
Goran M. Stojanovic
Textile-based microfluidic biosensors represent an innovative fusion of various multidisciplinary fields, including bioelectronics, material sciences, and microfluidics. Their potential in biomedicine is significant as they leverage textiles to achieve high demands of biocompatibility with the human body and conform to the irregular surfaces of the body. In the field of microfluidics, fabric coated with hydrophobic materials serves as channels through which liquids are transferred in precise amounts to the sensing element, which in this case is a biosensor. This paper presents a condensed overview of the current developments in textile-based microfluidics and biosensors in biomedical applications over the past 20 years (2005–2024). A literature search was performed using the Scopus database. The fabrication techniques and materials used are discussed in this paper, as these will be key in various modifications and advancements in textile-based microfluidics. Furthermore, we also address the gaps in the application of textile-based microfluidic analytical devices in biomedicine and discuss the potential solutions. Advances in textile-based microfluidics are enabled by various printing and fabric manufacturing techniques, such as screen printing, embroidery, and weaving. Integration of these devices into everyday clothing holds promise for future vital sign monitoring, such as glucose, albumin, lactate, and ion levels, as well as early detection of hereditary diseases through gene detection. Although most testing currently takes place in a laboratory or controlled environment, this field is rapidly evolving and pushing the boundaries of biomedicine, improving the quality of human life.