We studied the effects of fatigue of the index finger on indices of force variability in discrete and rhythmic accurate force production tasks performed by the index finger and by all four fingers pressing in parallel. An increase in the variance of the force produced by the fatigued index finger was expected. We hypothesized that the other fingers would also show increased variance of their forces, which would be accompanied by co-variation among the finger forces resulting in relatively preserved accuracy of performance. The subjects performed isometric tasks including maximal voluntary contraction (MVC) and accurate force production before and after a 1-min MVC fatiguing exercise by the index finger. During fatigue, there was a significant increase in the root mean square index of force variability during accurate force production by the index finger. In the four-finger tasks, the variance of the individual finger force increased for all four fingers, while the total force variance showed only a modest change. We quantified two components of variance in the space of hypothetical commands to fingers, finger modes. There was a large increase in the variance component that did not affect total force and a much smaller increase in the component that did. The results suggest an adaptive increase in force variance by nonfatigued elements as a strategy to attenuate effects of fatigue on accuracy of multi-element performance. These effects were unlikely to originate at the level of synchronization of motor units across muscle compartments but rather involved higher control levels.
The ultimate goal of any upper-limb neurorehabilitation procedure is to improve upper-limb functioning in daily life. While clinic-based assessments provide an assessment of what a patient can do, they do not completely reflect what a patient does in his/her daily life. The use of compensatory strategies such as the use of the less affected upper-limb or excessive use of trunk in daily life is a common behavioral pattern seen in patients with hemiparesis. To this end, there has been an increasing interest in the use of wearable sensors to objectively assess upper-limb functioning. This paper presents a framework for assessing upper-limb functioning using sensors by providing: (a) a set of definitions of important constructs associated with upper-limb functioning; (b) different visualization methods for evaluating upper-limb functioning; and (c) two new measures for quantifying how much an upper-limb is used and the relative bias in their use. The demonstration of some of these components is presented using data collected from inertial measurement units from a previous study. The proposed framework can help guide the future technical and clinical work in this area to realize valid, objective, and robust tools for assessing upper-limb functioning. This will in turn drive the refinement and standardization of the assessment of upper-limb functioning.
Measurement of hand kinematics is commonly done using data gloves and optical trackers and finds application in biomechanics, motor control research, clinical assessment, virtual reality etc. While data gloves are expensive and restrict the dexterity of the hand, optical trackers are susceptible to the line-of-sight problem and can be used only in a laboratory setting. Over the last decade, the use of Inertial Measurement Units (IMUs) to measure kinematics has gained traction due to their affordability and good accuracy. This paper presents the design and validation of a BNO055 IMU-based full Hand Kinematics Measurement System (HKMS). The best features from existing IMU-based devices were identified from the literature and incorporated. The HKMS streams orientation information of 16 BNO055 IMUs in real-time at 100 Hz via Wi-Fi or USB. A rigorous static and dynamic validation of the BNO055 IMU was done against 3D printed models and the highly accurate Electro Magnetic Tracking System (EMTS). The RMSE errors were found to be acceptable for the measurement of hand kinematics. Two experiments were conducted to collect hand kinematic data for various postures and object grasps using the HKMS and EMTS, respectively. Synergy analysis was done and range of motion of the joints was calculated using the two datasets. The results were compared to get an idea of the quality of the dataset collected using the HKMS. The results as well as the overall validation of the sensors indicate that the HKMS may be suitable for usage in a laboratory or clinical setup.