Measurement of hand kinematics is commonly done using data gloves and optical trackers and finds application in biomechanics, motor control research, clinical assessment, virtual reality etc. While data gloves are expensive and restrict the dexterity of the hand, optical trackers are susceptible to the line-of-sight problem and can be used only in a laboratory setting. Over the last decade, the use of Inertial Measurement Units (IMUs) to measure kinematics has gained traction due to their affordability and good accuracy. This paper presents the design and validation of a BNO055 IMU-based full Hand Kinematics Measurement System (HKMS). The best features from existing IMU-based devices were identified from the literature and incorporated. The HKMS streams orientation information of 16 BNO055 IMUs in real-time at 100 Hz via Wi-Fi or USB. A rigorous static and dynamic validation of the BNO055 IMU was done against 3D printed models and the highly accurate Electro Magnetic Tracking System (EMTS). The RMSE errors were found to be acceptable for the measurement of hand kinematics. Two experiments were conducted to collect hand kinematic data for various postures and object grasps using the HKMS and EMTS, respectively. Synergy analysis was done and range of motion of the joints was calculated using the two datasets. The results were compared to get an idea of the quality of the dataset collected using the HKMS. The results as well as the overall validation of the sensors indicate that the HKMS may be suitable for usage in a laboratory or clinical setup.
The dynamic dominance hypothesis of handedness suggests a distinct control strategy for the dominant and the non-dominant limb. The hypothesis demonstrated that the dominant proximal limb is tuned for optimal trajectory control while the non-dominant limb is tuned for a stable grasp. Whether the hypothesis can be extended to distal segments like fingers, especially during a five-fingered grasp, has been studied little. To examine this, an attempt was made to compare the prehensile synergies and force magnitudes of the dominant (DOM) and non-dominant hands (NDOM) during a 5-fingered prehension task. Participants traced a trapezoidal and inverse trapezoidal path with their thumbs on a sliding platform while holding a handle in static equilibrium. The DOM hand performed better only in the inverse trapezoid condition, exhibiting a reduced grip force and increased synergy index aligning with the dynamic dominance hypothesis. No differences were observed for the trapezoid condition, likely due to reduced task demands. The study also explored changes in anticipatory synergy adjustments between the DOM and NDOM hands, but the differences were non-significant. Overall, the DOM hand demonstrated better force coordination than the NDOM hand in challenging conditions. Applications of the study in the objective assessment of handedness were proposed.
The human hand needs a large number of sensors to measure kinematics owing to its large number of degrees of freedom. Existing devices like data gloves and optical trackers are associated with calibration, line of sight, and accuracy problems. In this paper, we attempt to measure the full hand kinematics using Electromagnetic Tracking Sensors (EMTS) which are accurate, free of line-of-sight problems, and require no calibration. However, EMTS provides output in the form of rotation groups which are defined on a nonlinear manifold. Hence, linear operations required for experimental analysis such as linear dimensionality reduction are not valid. Also, these sensors are expensive, utilize space in terms of cabling, and require a reduced sensor layout. In this paper, we present measurement methods, test the utility of linear and non-linear dimensionality reduction techniques on quaternions and exponential maps. We also performed sensor reduction using a Gini feature selection based on random forest algorithm. The kinematic measurement results show that EMTS yield superior posture reproduction with an error of less than 1 degree. Autoencoder, a nonlinear dimensionality reduction technique, was successfully applied on quaternions which was tuned to perform better than Principal Component Analysis (PCA) in reducing dimensions. The reduced sensor layout with 8 sensors was able to predict full hand kinematics with a Root Mean Square Error (RMSE) of 5.1 degrees.
20 April 2018 in International Journal of Engineering & Technology
The human hand is a complex manipulator with many joints that can perform various tasks. Neuroscience research has demonstrated that to perform any posture, the brain does not control the individual joints but relies on coactivation patterns called synergies that simultaneously control a set of joints. A combination of these synergies can then be used to reconstruct a variety of postures. While such a hypothesis has been demonstrated for single-handed tasks, a question that is not well-explored is whether such synergies can simultaneously control the joints of both hands during bimanual tasks. This paper attempted to address this question by exploring synergies obtained by performing Principal Component Analysis (PCA) on the kinematic data recorded from both the dominant and non-dominant hands of the participants as they performed bimanual tasks. The ability of synergies to reconstruct postures from a lower-dimensional subspace was presented, and an analysis of the separability of postures was performed using a classification algorithm. The results showed that the first 3 synergies explained greater than 80% variance in data, indicating that a few bimanual synergies can be utilized to control the fingers of both hands. The first three synergies could reconstruct postures with a Root Mean Square Error (RMSE) of 4° and classify tasks with an accuracy of 90%, demonstrating that the task-related information was retained in the lower dimensional subspace. This could significantly reduce control complexities while designing robotic or prosthetic distal upper limb devices.
Dental implants are an effective solution for tooth loss, offering long-term success rates exceeding 95%. However, challenges such as surgical complications, improper implant position, and prosthetic inaccuracies persists, often due to operator inexperience or anatomical complexities. Previously, Static Computer-Assisted Implant Surgery (sCAIS) and Dynamic Navigation Systems (DNS) have shown improved precision in implant placement. However, sCAIS often incurs high costs and manufacturing delays, while DNS faces challenges like line-of-sight issues and magnetic interference. Inertial measurement units (IMUs) present a promising alternative, offering real-time orientation feedback with advantages such as low cost, portability, and no line-of-sight restrictions. Despite their potential, research on IMU-based guidance for dental implant placement is limited, with unresolved issues related to accuracy under drilling vibrations, device miniaturization, and clinical usability. This paper presents the design and validation of a compact IMU-based system that measures handpiece angulation in real-time, transmitting mesiodistal and buccolingual orientation data to a wireless clinician-worn watch. A thorough validation was conducted to measure both the static and dynamic accuracies, as well as the response time of the system when exposed to dental handpiece drill vibrations. The impact of the built-in filtering features of the IMU and various tuning parameters on performance was also assessed. The validation results indicate that the IMU-assisted implantology device is a cost-effective and adaptable solution for precise implant placement.