Nicolas Zabler

Mr. Nicolas Zabler

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 December 2022 in Scientific Reports
Verified
Journal Article
Open access
PDF file
SBSebastian Böttcher
Sebastian Böttcher
SVSolveig Vieluf
Solveig Vieluf
EBElisa Bruno
Elisa Bruno
Boney JosephBoney Joseph
Boney Joseph
NENino Epitashvili
Nino Epitashvili
TLTobias Loddenkemper
Tobias Loddenkemper
Wearable recordings of neurophysiological signals captured from the wrist offer enormous potential for seizure monitoring. Yet, data quality remains one of the most challenging factors that impact data reliability. We suggest a combined data quality assessment tool for the evaluation of multimodal wearable data. We analyzed data from patients with epilepsy from four epilepsy centers. Patients wore wristbands recording accelerometry, electrodermal activity, blood volume pulse, and skin temperature. We calculated data completeness and assessed the time the device was worn (on-body), and modality-specific signal quality scores. We included 37,166 h from 632 patients in the inpatient and 90,776 h from 39 patients in the outpatient setting. All modalities were affected by artifacts. Data loss was higher when using data streaming (up to 49% among inpatient cohorts, averaged across respective recordings) as compared to onboard device recording and storage (up to 9%). On-body scores, estimating the percentage of time a device was worn on the body, were consistently high across cohorts (more than 80%). Signal quality of some modalities, based on established indices, was higher at night than during the day. A uniformly reported data quality and multimodal signal quality index is feasible, makes study results more comparable, and contributes to the development of devices and evaluation routines necessary for seizure monitoring.

23 August 2023 in Annals of Clinical and Translational Neurology
Verified
Journal Article
Open access
ASAndreas Schulze‐Bonhage
Andreas Schulze‐Bonhage
MRMark P. Richardson
Mark P. Richardson
ABArmin Brandt
Armin Brandt
NZNicolas Zabler
Nicolas Zabler
MDMatthias Dümpelmann
Matthias Dümpelmann
VAVictoria San Antonio‐Arce
Victoria San Antonio‐Arce
Objective: Circadian and multidien cycles of seizure occurrence are increasingly discussed as to their biological underpinnings and in the context of seizure forecasting. This study analyzes if patient reported seizures provide valid data on such cyclical occurrence.Methods: We retrospectively studied if circadian cycles derived from patient‐based reporting reflect the objective seizure documentation in 2003 patients undergoing in‐patient video‐EEG monitoring.Results: Only 24.1% of more than 29000 seizures documented were accompanied by patient notifications. There was cyclical underreporting of seizures with a maximum during nighttime, leading to significant deviations in the circadian distribution of seizures. Significant cyclical deviations were found for focal epilepsies originating from both, frontal and temporal lobes, and for different seizure types (in particular, focal unaware and focal to bilateral tonic–clonic seizures).Interpretation: Patient seizure diaries may reflect a cyclical reporting bias rather than the true circadian seizure distributions. Cyclical underreporting of seizures derived from patient‐based reports alone may lead to suboptimal treatment schemes, to an underestimation of seizure‐associated risks, and may pose problems for valid seizure forecasting. This finding strongly supports the use of objective measures to monitor cyclical distributions of seizures and for studies and treatment decisions based thereon.

26 April 2022 in Sensors
Verified
Journal Article
Open access
PDF file
SBSebastian Böttcher
Sebastian Böttcher
EBElisa Bruno
Elisa Bruno
NENino Epitashvili
Nino Epitashvili
MDMatthias Dümpelmann
Matthias Dümpelmann
NZNicolas Zabler
Nicolas Zabler
ASAndreas Schulze-Bonhage
Andreas Schulze-Bonhage
Focal onset epileptic seizures are highly heterogeneous in their clinical manifestations, and a robust seizure detection across patient cohorts has to date not been achieved. Here, we assess and discuss the potential of supervised machine learning models for the detection of focal onset motor seizures by means of a wrist-worn wearable device, both in a personalized context as well as across patients. Wearable data were recorded in-hospital from patients with epilepsy at two epilepsy centers. Accelerometry, electrodermal activity, and blood volume pulse data were processed and features for each of the biosignal modalities were calculated. Following a leave-one-out approach, a gradient tree boosting machine learning model was optimized and tested in an intra-subject and inter-subject evaluation. In total, 20 seizures from 9 patients were included and we report sensitivities of 67% to 100% and false alarm rates of down to 0.85 per 24 h in the individualized assessment. Conversely, for an inter-subject seizure detection methodology tested on an out-of-sample data set, an optimized model could only achieve a sensitivity of 75% at a false alarm rate of 13.4 per 24 h. We demonstrate that robustly detecting focal onset motor seizures with tonic or clonic movements from wearable data may be possible for individuals, depending on specific seizure manifestations.

9 July 2024 in Scientific Reports
Verified
Journal Article
Open access
PDF file
NZNicolas Zabler
Nicolas Zabler
LSLauren Swinnen
Lauren Swinnen
ABAndrea Biondi
Andrea Biondi
YNYulia Novitskaya
Yulia Novitskaya
ESElisa Schütz
Elisa Schütz
MHMartin Hirsch
Martin Hirsch
People with epilepsy frequently under- or inaccurately report their seizures, which poses a challenge for evaluating their treatment. The introduction of epilepsy health apps provides a novel approach that could improve seizure documentation. This study assessed the documentation performance of an app-based seizure diary and a conventional paper seizure diary. At two tertiary epilepsy centers patients were asked to use one of two offered methods to report their seizures (paper or app diary) during their stay in the epilepsy monitoring unit. The performances of both methods were assessed based on the gold standard of video-EEG annotations. In total 89 adults (54 paper and 35 app users) with focal epilepsy were included in the analysis, of which 58 (33 paper and 25 app users) experienced at least one seizure and made at least one seizure diary entry. We observed a high precision of 85.7% for the app group, whereas the paper group’s precision was lower due to overreporting (66.9%). Sensitivity was similar for both methods. Our findings imply that performance of seizure self-reporting is patient-dependent but is more precise for patients who are willing to use digital apps. This may be relevant for treatment decisions and future clinical trial design.

1 June 2024 in Physiological Measurement
Verified
Journal Article
Closed access
JZJingwei Zhang
Jingwei Zhang
LSLauren Swinnen
Lauren Swinnen
Christos ChatzichristosChristos Chatzichristos
Christos Chatzichristos
VBVictoria Broux
Victoria Broux
RPRenee Proost
Renee Proost
MVMaarten De Vos
Maarten De Vos
Objective. This paper aims to investigate the possibility of detecting tonic-clonic seizures (TCSs) with behind-the-ear, two-channel wearable electroencephalography (EEG), and to evaluate its added value to non-EEG modalities in TCS detection. Methods. We included 27 participants with a total of 44 TCSs from the European multicenter study SeizeIT2. The wearable Sensor Dot (Byteflies) was used to measure behind-the-ear EEG, electromyography (EMG), electrocardiography, accelerometry (ACC) and gyroscope. We evaluated automatic unimodal detection of TCSs, using sensitivity, precision, false positive rate (FPR) and F1-score. Subsequently, we fused the different modalities and again assessed performance. Algorithm-labeled segments were then provided to two experts, who annotated true positive TCSs, and discarded false positives. Results. Wearable EEG outperformed the other single modalities with a sensitivity of 100% and a FPR of 10.3/24 h. The combination of wearable EEG and EMG proved most clinically useful, delivering a sensitivity of 97.7%, an FPR of 0.4/24 h, a precision of 43%, and an F1-score of 59.7%. The highest overall performance was achieved through the fusion of wearable EEG, EMG, and ACC, yielding a sensitivity of 90.9%, an FPR of 0.1/24 h, a precision of 75.5%, and an F1-score of 82.5%. Conclusions. In TCS detection with a wearable device, combining EEG with EMG, ACC or both resulted in a remarkable reduction of FPR, while retaining a high sensitivity. Significance. Adding wearable EEG could further improve TCS detection, relative to extracerebral-based systems.

8 September 2021 in Sensors
Verified
Journal Article
Open access
PDF file
MGMartin Glasstetter
Martin Glasstetter
SBSebastian Böttcher
Sebastian Böttcher
NZNicolas Zabler
Nicolas Zabler
NENino Epitashvili
Nino Epitashvili
MDMatthias Dümpelmann
Matthias Dümpelmann
ASAndreas Schulze-Bonhage
Andreas Schulze-Bonhage
Photoplethysmography (PPG) as an additional biosignal for a seizure detector has been underutilized so far, which is possibly due to its susceptibility to motion artifacts. We investigated 62 focal seizures from 28 patients with electrocardiography-based evidence of ictal tachycardia (IT). Seizures were divided into subgroups: those without epileptic movements and those with epileptic movements not affecting and affecting the extremities. PPG-based heart rate (HR) derived from a wrist-worn device was calculated for sections with high signal quality, which were identified using spectral entropy. Overall, IT based on PPG was identified in 37 of 62 (60%) seizures (9/19, 7/8, and 21/35 in the three groups, respectively) and could be found prior to the onset of epileptic movements affecting the extremities in 14/21 seizures. In 30/37 seizures, PPG-based IT was in good temporal agreement (<10 s) with ECG-based IT, with an average delay of 5.0 s relative to EEG onset. In summary, we observed that the identification of IT by means of a wearable PPG sensor is possible not only for non-motor seizures but also in motor seizures, which is due to the early manifestation of IT in a relevant subset of focal seizures. However, both spontaneous and epileptic movements can impair PPG-based seizure detection.