Lauren Swinnen

Lauren Swinnen

Auto-generated profile, based on publicly available information

Lauren Swinnen

Laboratory for Epilepsy Research, KU Leuven, Leuven, Belgium

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 September 2021 in Epilepsia
Verified
Journal Article
Open access
PDF file
LSLauren Swinnen
Lauren Swinnen
Christos ChatzichristosChristos Chatzichristos
Christos Chatzichristos
KJKatrien Jansen
Katrien Jansen
LLLieven Lagae
Lieven Lagae
CDChantal Depondt
Chantal Depondt
WPWim Van Paesschen
Wim Van Paesschen
Summary: Objective: Patients with absence epilepsy sensitivity <10% of their absences. The clinical gold standard to assess absence epilepsy is a 24‐h electroencephalographic (EEG) recording, which is expensive, obtrusive, and time‐consuming to review. We aimed to (1) investigate the performance of an unobtrusive, two‐channel behind‐the‐ear EEG‐based wearable, the Sensor Dot (SD), to detect typical absences in adults and children; and (2) develop a sensitive patient‐specific absence seizure detection algorithm to reduce the review time of the recordings.Methods: We recruited 12 patients (median age = 21 years, range = 8–50; seven female) who were admitted to the epilepsy monitoring units of University Hospitals Leuven for a 24‐h 25‐channel video‐EEG recording to assess their refractory typical absences. Four additional behind‐the‐ear electrodes were attached for concomitant recording with the SD. Typical absences were defined as 3‐Hz spike‐and‐wave discharges on EEG, lasting 3 s or longer. Seizures on SD were blindly annotated on the full recording and on the algorithm‐labeled file and consequently compared to 25‐channel EEG annotations. Patients or caregivers were asked to keep a seizure diary. Performance of the SD and seizure diary were measured using the F1 score.Results: We concomitantly recorded 284 absences on video‐EEG and SD. Our absence detection algorithm had a sensitivity of .983 and false positives per hour rate of .9138. Blind reading of full SD data resulted in sensitivity of .81, precision of .89, and F1 score of .73, whereas review of the algorithm‐labeled files resulted in scores of .83, .89, and .87, respectively. Patient self‐reporting gave sensitivity of .08, precision of 1.00, and F1 score of .15.Significance: Using the wearable SD, epileptologists were able to reliably detect typical absence seizures. Our automated absence detection algorithm reduced the review time of a 24‐h recording from 1‐2 h to around 5–10 min.

9 July 2021 in Epilepsia
Verified
Journal Article
Open access
PDF file
KVKaat Vandecasteele
Kaat Vandecasteele
TCThomas De Cooman
Thomas De Cooman
Christos ChatzichristosChristos Chatzichristos
Christos Chatzichristos
ECEvy Cleeren
Evy Cleeren
LSLauren Swinnen
Lauren Swinnen
BHBorbála Hunyadi
Borbála Hunyadi
Objective: Wearable seizure detection devices could provide more reliable seizure documentation outside the hospital compared to seizure self‐reporting by patients, which is the current standard. Previously, during the SeizeIT1 project, we studied seizure detection based on behind‐the‐ear electroencephalography (EEG). However, the obtained sensitivities were too low for practical use, because not all seizures are associated with typical ictal EEG patterns. Therefore, in this paper, we aim to develop a multimodal automated seizure detection algorithm integrating behind‐the‐ear EEG and electrocardiography (ECG) for detecting focal seizures. In this framework, we quantified the added value of ECG to behind‐the‐ear EEG.Methods: This study analyzed three multicenter databases consisting of 135 patients having focal epilepsy and a total of 896 seizures. A patient‐specific multimodal automated seizure detection algorithm was developed using behind‐the‐ear/temporal EEG and single‐lead ECG. The EEG and ECG data were processed separately using machine learning methods. A late integration approach was applied for fusing those predictions.Results: The multimodal algorithm outperformed the EEG‐based algorithm in two of three databases, with an increase of 11% and 8% in sensitivity for the same false alarm rate.Significance: ECG can be of added value to an EEG‐based seizure detection algorithm using only behind‐the‐ear/temporal lobe electrodes for patients with focal epilepsy.

20 April 2023 in Bioengineering
Verified
Journal Article
Open access
PDF file
MBMiguel Bhagubai
Miguel Bhagubai
KVKaat Vandecasteele
Kaat Vandecasteele
LSLauren Swinnen
Lauren Swinnen
JMJaiver Macea
Jaiver Macea
CCChristos Chatzichristos
Christos Chatzichristos
WPWim Van Paesschen
Wim Van Paesschen
Long-term home monitoring of people living with epilepsy cannot be achieved using the standard full-scalp electroencephalography (EEG) coupled with video. Wearable seizure detection devices, such as behind-the-ear EEG (bte-EEG), offer an unobtrusive method for ambulatory follow-up of this population. Combining bte-EEG with electrocardiography (ECG) can enhance automated seizure detection performance. However, such frameworks produce high false alarm rates, making visual review necessary. This study aimed to evaluate a semi-automated multimodal wearable seizure detection framework using bte-EEG and ECG. Using the SeizeIT1 dataset of 42 patients with focal epilepsy, an automated multimodal seizure detection algorithm was used to produce seizure alarms. Two reviewers evaluated the algorithm’s detections twice: (1) using only bte-EEG data and (2) using bte-EEG, ECG, and heart rate signals. The readers achieved a mean sensitivity of 59.1% in the bte-EEG visual experiment, with a false detection rate of 6.5 false detections per day. Adding ECG resulted in a higher mean sensitivity (62.2%) and a largely reduced false detection rate (mean of 2.4 false detections per day), as well as an increased inter-rater agreement. The multimodal framework allows for efficient review time, making it beneficial for both clinicians and patients.

9 July 2024 in Scientific Reports
Verified
Journal Article
Open access
PDF file
NZNicolas Zabler
Nicolas Zabler
LSLauren Swinnen
Lauren Swinnen
ABAndrea Biondi
Andrea Biondi
YNYulia Novitskaya
Yulia Novitskaya
ESElisa Schütz
Elisa Schütz
MHMartin Hirsch
Martin Hirsch
People with epilepsy frequently under- or inaccurately report their seizures, which poses a challenge for evaluating their treatment. The introduction of epilepsy health apps provides a novel approach that could improve seizure documentation. This study assessed the documentation performance of an app-based seizure diary and a conventional paper seizure diary. At two tertiary epilepsy centers patients were asked to use one of two offered methods to report their seizures (paper or app diary) during their stay in the epilepsy monitoring unit. The performances of both methods were assessed based on the gold standard of video-EEG annotations. In total 89 adults (54 paper and 35 app users) with focal epilepsy were included in the analysis, of which 58 (33 paper and 25 app users) experienced at least one seizure and made at least one seizure diary entry. We observed a high precision of 85.7% for the app group, whereas the paper group’s precision was lower due to overreporting (66.9%). Sensitivity was similar for both methods. Our findings imply that performance of seizure self-reporting is patient-dependent but is more precise for patients who are willing to use digital apps. This may be relevant for treatment decisions and future clinical trial design.

1 June 2024 in Physiological Measurement
Verified
Journal Article
Closed access
JZJingwei Zhang
Jingwei Zhang
LSLauren Swinnen
Lauren Swinnen
Christos ChatzichristosChristos Chatzichristos
Christos Chatzichristos
VBVictoria Broux
Victoria Broux
RPRenee Proost
Renee Proost
MVMaarten De Vos
Maarten De Vos
Objective. This paper aims to investigate the possibility of detecting tonic-clonic seizures (TCSs) with behind-the-ear, two-channel wearable electroencephalography (EEG), and to evaluate its added value to non-EEG modalities in TCS detection. Methods. We included 27 participants with a total of 44 TCSs from the European multicenter study SeizeIT2. The wearable Sensor Dot (Byteflies) was used to measure behind-the-ear EEG, electromyography (EMG), electrocardiography, accelerometry (ACC) and gyroscope. We evaluated automatic unimodal detection of TCSs, using sensitivity, precision, false positive rate (FPR) and F1-score. Subsequently, we fused the different modalities and again assessed performance. Algorithm-labeled segments were then provided to two experts, who annotated true positive TCSs, and discarded false positives. Results. Wearable EEG outperformed the other single modalities with a sensitivity of 100% and a FPR of 10.3/24 h. The combination of wearable EEG and EMG proved most clinically useful, delivering a sensitivity of 97.7%, an FPR of 0.4/24 h, a precision of 43%, and an F1-score of 59.7%. The highest overall performance was achieved through the fusion of wearable EEG, EMG, and ACC, yielding a sensitivity of 90.9%, an FPR of 0.1/24 h, a precision of 75.5%, and an F1-score of 82.5%. Conclusions. In TCS detection with a wearable device, combining EEG with EMG, ACC or both resulted in a remarkable reduction of FPR, while retaining a high sensitivity. Significance. Adding wearable EEG could further improve TCS detection, relative to extracerebral-based systems.

11 December 2023 in Epilepsia
Verified
Journal Article
Open access
LSLauren Swinnen
Lauren Swinnen
CCChristos Chatzichristos
Christos Chatzichristos
MBMiguel Bhagubai
Miguel Bhagubai
VBVictoria Broux
Victoria Broux
NZNicolas Zabler
Nicolas Zabler
WPWim Van Paesschen
Wim Van Paesschen
Objective: Home monitoring of 3‐Hz spike–wave discharges (SWDs) in patients with refractory absence epilepsy could improve clinical care by replacing the inaccurate seizure diary with objective counts. We investigated the use and performance of the Sensor Dot (Byteflies) wearable in persons with absence epilepsy in their home environment.Methods: Thirteen participants (median age = 22 years, 11 female) were enrolled at the university hospitals of Leuven and Freiburg. At home, participants had to attach the Sensor Dot and behind‐the‐ear electrodes to record two‐channel electroencephalogram (EEG), accelerometry, and gyroscope data. Ground truth annotations were created during a visual review of the full Sensor Dot recording. Generalized SWDs were annotated if they were 3 Hz and at least 3 s on EEG. Potential 3‐Hz SWDs were flagged by an automated seizure detection algorithm, (1) using only EEG and (2) with an additional postprocessing step using accelerometer and gyroscope to discard motion artifacts. Afterward, two readers (W.V.P. and L.S.) reviewed algorithm‐labeled segments and annotated true positive detections. Sensitivity, precision, and F1 score were calculated. Patients had to keep a seizure diary and complete questionnaires about their experiences.Results: Total recording time was 394 h 42 min. Overall, 234 SWDs were captured in 11 of 13 participants. Review of the unimodal algorithm‐labeled recordings resulted in a mean sensitivity of .84, precision of .93, and F1 score of .89. Visual review of the multimodal algorithm‐labeled segments resulted in a similar F1 score and shorter review time due to fewer false positive labels. Participants reported that the device was comfortable and that they would be willing to wear it on demand of their neurologist, for a maximum of 1 week or with intermediate breaks.Significance: The Sensor Dot improved seizure documentation at home, relative to patient self‐reporting. Additional benefits were the short review time and the patients' device acceptance due to user‐friendliness and comfortability.