Changzhou Yu

Changzhou Yu


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 February 2019 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
HXHaizhen Xu
Haizhen Xu
CYChangzhou Yu
Changzhou Yu
CLChun Liu
Chun Liu
QWQinglong Wang
Qinglong Wang
FLFang Liu
Fang Liu
FLFei Li
Fei Li
Distributed power generators in islanded microgrid usually adopt droop control strategy or virtual synchronous generator control strategy to simulate Q-U droop characteristic of synchronous generators for voltage support ability enhancement and reliability improvement. However, because the distributed power generators' capacities and locations are random, they cannot share reactive load proportional to their rated capacity, resulting in overload protection, and even system instability. In order to improve reactive power sharing precision, voltage control precision and system stability simultaneously, an improved reactive power sharing algorithm combining virtual impedance and virtual capacitor is proposed in this paper. Firstly, the three existing open-loop reactive power sharing strategies are summarized and the effect of their parameters on reactive power sharing error, steady-state voltage deviation and system stability are analyzed. Afterwards, based on the analysis results, a reasonable configuration of virtual impedance and virtual capacitor values are put forward to realize the control targets of reducing steady-state reactive power sharing error, improving voltage control precision and system stability meanwhile. Finally, simulation and experimental platforms are built to verify the effectiveness of the proposed strategy.

7 June 2016 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
CYChangzhou Yu
Changzhou Yu
XZXing Zhang
Xing Zhang
FLFang Liu
Fang Liu
FLFei Li
Fei Li
HXHaizhen Xu
Haizhen Xu
HNHua Ni
Hua Ni
With increasing penetration of renewable energy sources into modern power systems, multiparallel inverters are commonly employed in the interface to the utility grid, giving rise to potential resonance problems. In order to better understand the issue, resonance of multiparallel inverters is analyzed under an asynchronous carrier. First, multiparallel inverter equivalent circuits are modeled within a controlled bandwidth. In order to investigate resonance characteristics under an asynchronous carrier, a crossover filter function is used to separate output currents of different frequencies for a two-parallel inverter to analyze the output current frequency response. With this approach, resonance characteristics are focused under asynchronous conditions, and the impact of shifting LCL parameters on resonance is examined. The influence of paralleled inverter number on output currents is examined, and the analysis is expanded to multiparallel inverter systems to determine the resonance characteristics. Experimental results validate the developed models and the proposed resonance characteristics.

24 October 2018 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Closed access
CYChangzhou Yu
Changzhou Yu
HXHaizhen Xu
Haizhen Xu
CLChun Liu
Chun Liu
QWQinglong Wang
Qinglong Wang
XZXing Zhang
Xing Zhang
With increasing penetration of renewable energy sources into distributed power systems, multi-parallel inverters are commonly employed in the interface to the utility grid, giving rise to potential resonance problems. Aiming at this issue, common-mode resonance of single inverter and multi-parallel inverters are analyzed. First, single inverter common-mode circuits model is built. Common-mode paths are found in it and the admittances of each path are analyzed. Based on it, multi-parallel inverters equivalent circuits are modeled and analyzed. In order to investigate common-mode resonance characteristics, self-coupled and mutual-coupled paths are analyzed and compared to single inverter's path. To get more accuracy resonance characteristics, a crossover filter function is introduced and used to separate output common-mode currents at different frequencies for two-parallel inverters. The impact of parasitic capacitance on resonance is examined. Experimental results validate the developed models and the proposed resonance characteristics.

12 July 2024 in Electric Power Systems Research
Verified
Journal Article
Closed access
CYChangzhou Yu
Changzhou Yu
HXHaizhen Xu
Haizhen Xu
CCChen Chen
Chen Chen
MSMeimei Sun
Meimei Sun
XFXinxin Fu
Xinxin Fu
XZXing Zhang
Xing Zhang

13 May 2025 in IEEE Open Journal of Power Electronics
Verified
Journal Article
Open access
CYChangzhou Yu
Changzhou Yu
QWQin Wang
Qin Wang
WFWei Fang
Wei Fang
YWYifei Wang
Yifei Wang
HDHaiyang Diao
Haiyang Diao
LGLeilei Guo
Leilei Guo
With the rapid development of renewable energy, the widespread integration of power electronic devices into power generation systems has led to increased grid impedance and reduced short-circuit ratio (SCR), causing the grid to exhibit characteristics of weak or even extremely weak grids. This has posed significant challenges to traditional grid-following control strategies, resulting in increased grid harmonics, heightened instability risks, and frequent power generation system failures. In contrast, grid-forming control strategies, which provide active voltage support, have demonstrated superior stability in weak grid conditions. However, neither grid-following nor grid-forming control strategies alone can comprehensively meet the requirements of power systems in terms of stability, economic efficiency, and grid support. To address these challenges, this paper proposes a model predictive control (MPC) strategy that integrates grid-following and grid-forming control. First, a mathematical model of the grid-connected inverter is established, and stability analyses are conducted for both grid-following and grid-forming modes. Second, model predictive control algorithms are thoroughly investigated for both modes, and an optimized control strategy is selected through comparative analysis. Finally, the effectiveness of the proposed strategy is validated using a hardware-in-the-loop (HIL) simulation platform. Experimental results demonstrate that the proposed method significantly enhances the stability of grid-connected inverters under conditions of significantly increased grid impedance and reduced SCR, ensuring reliable operation of power systems. This approach holds substantial practical application value for modern power systems.

10 July 2024 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
ZWZhenjun Wu
Zhenjun Wu
ZLZhenkun Liu
Zhenkun Liu
HZHong Zhu
Hong Zhu
LGLeilei Guo
Leilei Guo
QYQingyang Ye
Qingyang Ye
TZTao Zhao
Tao Zhao
The inductance parameter is crucial to realize high-precision model predictive control (MPC) for grid-connected inverter (GCI), while the traditional inductance estimation method is sensitive to the grid frequency deviation and cannot work normally when the active power is zero. To solve these problems, a new inductance online estimation method based on a full order sliding mode voltage observer (FSMVO) is proposed. First, the drawbacks of the traditional FSMVO-based inductance estimation method are analyzed. Second, a new inductance estimation method is proposed, which uses the error between the observed grid voltage and the actual one passed through a filter, whose transfer function is the same as the one of FSMVO. As a result, the new inductance estimation method is immune to the grid frequency deviation. Moreover, a new Lyapunov function is also designed in this article to deduce the new inductance estimation method, which can work well, no matter the active power is zero or not. Finally, by substituting the estimated inductance parameter into the MPC algorithm, the control performance of GCI can be improved. The effectiveness and accuracy of the proposed inductance estimation method are verified by experimental researches.