Ali Khumaeni

Dr. Ali Khumaeni

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 November 2013 in Optics Express
Verified
Journal Article
Closed access
PDF file
AKAli Khumaeni
Ali Khumaeni
TMTampo Motonobu
Tampo Motonobu
AKAkaoka Katsuaki
Akaoka Katsuaki
MMMiyabe Masabumi
Miyabe Masabumi
WIWakaida Ikuo
Wakaida Ikuo
Intensified microwave coupled by a loop antenna (diameter of 3 mm) has been employed to enhance the laser-induced breakdown spectroscopy (LIBS) emission. In this method, a laser plasma was induced on Gd2O3 sample at a reduced pressure by focusing a pulsed Nd:YAG laser (532 nm, 10 ns, 5 mJ) at a local point, at which electromagnetic field was produced by introducing microwave radiation using loop antenna. The plasma emission was significantly enhanced by absorbing the microwave radiation, resulting in high-temperature plasma and long-lifetime plasma emission. By using this method, the enhancement of Gd lines was up to 32 times, depending upon the emission lines observed. A linear calibration curve of Ca contained in the Gd2O3 sample was made. The detection limit of Ca was approximately 2 mg/kg. This present method is very useful for identification of trace elements in nuclear fuel and radioactive materials.

13 March 2011 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Closed access
PDF file
AKAli Khumaeni
Ali Khumaeni
ZLZener Sukra Lie
Zener Sukra Lie
HNHideaki Niki
Hideaki Niki
KKKoo Hendrik Kurniawan
Koo Hendrik Kurniawan
ETEfendy Tjoeng
Efendy Tjoeng
KKKiichiro Kagawa
Kiichiro Kagawa

1 December 2008 in Applied Spectroscopy
Verified
Journal Article
Closed access
PDF file
AKAli Khumaeni
Ali Khumaeni
MRMuliadi Ramli
Muliadi Ramli
YDYoji Deguchi
Yoji Deguchi
YLYong Inn Lee
Yong Inn Lee
NINasrullah Idris
Nasrullah Idris
KKKiichiro Kagawa
Kiichiro Kagawa
Taking advantage of the differences between the interactions of transversely excited atmospheric (TEA) CO2 lasers with metal and with organic powder, a new technique for the direct analysis of food powder samples has been developed. In this technique, the powder samples were placed into a small hole with a diameter of 2 mm and a depth of 3 mm and covered by a metal mesh. The TEA CO2 laser (1500 mJ, 200 ns) was focused on the powder sample surfaces, passing through the metal mesh, at atmospheric pressure in nitrogen gas. It is hypothesized that the small hole functions to confine the powder particles and suppresses the blowing-off of sample, while the metal mesh works as the source of electrons to initiate the strong gas breakdown plasma. The confined powder particles are then ablated by laser irradiation and the ablated particles move into the strong gas breakdown plasma region to be atomized and excited; this method cannot be applied for the case of Nd:YAG lasers because in such case the metal mesh itself was ablated by the laser irradiation. A quantitative analysis of a milk powder sample containing different concentrations of Ca was successfully demonstrated, resulting in a good linear calibration curve with high precision.

24 June 2016 in Frontiers of Physics
Verified
Journal Article
Closed access
PDF file
AKAli Khumaeni
Ali Khumaeni
KAKatsuaki Akaoka
Katsuaki Akaoka
MMMasabumi Miyabe
Masabumi Miyabe
IWIkuo Wakaida
Ikuo Wakaida
We studied experimentally the effect of microwaves (MWs) on the enhancement of plasma emission achieved by laser-induced breakdown spectroscopy (LIBS). A laser plasma was generated on a calcium oxide pellet by a Nd:YAG laser (5 mJ, 532 nm, 8 ns) in reduced-pressure argon surrounding gas. A MW radiation (400 W) was injected into the laser plasma via a loop antenna placed immediately above the laser plasma to enhance the plasma emission. The results confirmed that when the electromagnetic field was introduced into the laser plasma region by the MWs, the lifetime of the plasma was extended from 50 to 500 µs, similar to the MW duration. Furthermore, the plasma temperature and electron density increased to approximately 10900 K and 1.5×1018 cm-3, respectively and the size of the plasma emission was extended to 15 mm in diameter. As a result, the emission intensity of Ca lines obtained using LIBS with MWs was enhanced by approximately 200 times compared to the case of LIBS without MWs.

1 August 2015 in Spectrochimica Acta Part B: Atomic Spectroscopy
Verified
Journal Article
Open access
MMM. Miyabe
M. Miyabe
MOM. Oba
M. Oba
HIH. Iimura
H. Iimura
KAK. Akaoka
K. Akaoka
AKAli Khumaeni
Ali Khumaeni
IWI. Wakaida
I. Wakaida

30 August 2016 in Journal of Radioanalytical and Nuclear Chemistry
Verified
Journal Article
Closed access
PDF file
AKAli Khumaeni
Ali Khumaeni
MMMasabumi Miyabe
Masabumi Miyabe
KAKatsuaki Akaoka
Katsuaki Akaoka
IWIkuo Wakaida
Ikuo Wakaida