Stéphanie Corde

Dr. Stéphanie Corde

orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 July 2004 in British Journal of Cancer
Verified
Journal Article
Open access
PDF file
SCStéphanie Corde
Stéphanie Corde
AJA Joubert
A Joubert
JAJ F Adam
J F Adam
ACA M Charvet
A M Charvet
JBJ F Le Bas
J F Le Bas
JBJacques Balosso
Jacques Balosso
This study was designed to experimentally evaluate the optimal X-ray energy for increasing the radiation energy absorbed in tumours loaded with iodinated compounds, using the photoelectric effect. SQ20B human cells were irradiated with synchrotron monochromatic beam tuned at 32.8, 33.5, 50 and 70 keV. Two cell treatments were compared to the control: cells suspended in 10 mg ml−1 of iodine radiological contrast agent or cells pre-exposed with 10 μM of iodo-desoxyuridine (IUdR) for 48 h. Our radiobiological end point was clonogenic cell survival. Cells irradiated with both iodine compounds exhibited a radiation sensitisation enhancement. Moreover, it was energy dependent, with a maximum at 50 keV. At this energy, the sensitisation calculated at 10% survival was equal to 2.03 for cells suspended in iodinated contrast agent and 2.60 for IUdR. Cells pretreated with IUdR had higher sensitisation factors over the energy range than for those suspended in iodine contrast agent. Also, their survival curves presented no shoulder, suggesting complex lethal damages from Auger electrons. Our results confirm the existence of the 50 keV energy optimum for a binary therapeutic irradiation based on the presence of stable iodine in tumours and an external irradiation. Monochromatic synchrotron radiotherapy concept is hence proposed for increasing the differential effect between healthy and cancerous tissue irradiation.

1 November 2016 in Physica Medica
Verified
Journal Article
Closed access
CSCallum Stewart
Callum Stewart
Konstantin KonstantinovKonstantin Konstantinov
Konstantin Konstantinov
SMSally McKinnon
Sally McKinnon
SGSusanna Guatelli
Susanna Guatelli
MLMichael Lerch
Michael Lerch
SCStéphanie Corde
Stéphanie Corde

22 June 2005 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
EBE Bräuer-Krisch
E Bräuer-Krisch
HRH Requardt
H Requardt
PRP Régnard
P Régnard
SCStéphanie Corde
Stéphanie Corde
ESE Siegbahn
E Siegbahn
ABA Bravin
A Bravin
Microbeam radiation therapy (MRT) has the potential to treat infantile brain tumours when other kinds of radiotherapy would be excessively toxic to the developing normal brain. MRT uses extraordinarily high doses of x-rays but provides unusual resistance to radioneurotoxicity, presumably from the migration of endothelial cells from 'valleys' into 'peaks', i.e., into directly irradiated microslices of tissues. We present a novel irradiation geometry which results in a tolerable valley dose for the normal tissue and a decreased peak-to-valley dose ratio (PVDR) in the tumour area by applying an innovative cross-firing technique. We propose an MRT technique to orthogonally crossfire two arrays of parallel, nonintersecting, mutually interspersed microbeams that produces tumouricidal doses with small PVDRs where the arrays meet and tolerable radiation doses to normal tissues between the microbeams proximal and distal to the tumour in the paths of the arrays.

1 August 2011 in International Journal of Radiation Oncology, Biology, Physics
Verified
Journal Article
Closed access
SSSara Sabatasso
Sara Sabatasso
JLJean Albert Laissue
Jean Albert Laissue
RHRuslan Hlushchuk
Ruslan Hlushchuk
WGWerner Graber
Werner Graber
ABAlberto Bravin
Alberto Bravin
Valentin DjonovValentin Djonov
Valentin Djonov

1 May 2014 in International Journal of Nanomedicine
Verified
Journal Article
Open access
PDF file
WRWan Nordiana Rahman
Wan Nordiana Rahman
MGMoshi Geso
Moshi Geso
NYNaoto Yagi
Naoto Yagi
SASiti Aishah Abdul Aziz
Siti Aishah Abdul Aziz
SCStéphanie Corde
Stéphanie Corde
NANathan Annabell
Nathan Annabell
Gold nanoparticles have been shown to enhance radiation doses delivered to biological targets due to the high absorption coefficient of gold atoms, stemming from their high atomic number (Z) and physical density. These properties significantly increase the likelihood of photoelectric effects and Compton scattering interactions. Gold nanoparticles are a novel radiosensitizing agent that can potentially be used to increase the effectiveness of current radiation therapy techniques and improve the diagnosis and treatment of cancer. However, the optimum radiosensitization effect of gold nanoparticles is strongly dependent on photon energy, which theoretically is predicted to occur in the kilovoltage range of energy. In this research, synchrotron-generated monoenergetic X-rays in the 30–100 keV range were used to investigate the energy dependence of radiosensitization by gold nanoparticles and also to determine the photon energy that produces optimum effects. This investigation was conducted using cells in culture to measure dose enhancement. Bovine aortic endothelial cells with and without gold nanoparticles were irradiated with X-rays at energies of 30, 40, 50, 60, 70, 81, and 100 keV. Trypan blue exclusion assays were performed after irradiation to determine cell viability. Cell radiosensitivity enhancement was indicated by the dose enhancement factor which was found to be maximum at 40 keV with a value of 3.47. The dose enhancement factor obtained at other energy levels followed the same direction as the theoretical calculations based on the ratio of the mass energy absorption coefficients of gold and water. This experimental evidence shows that the radiosensitization effect of gold nanoparticles varies with photon energy as predicted from theoretical calculations. However, prediction based on theoretical assumptions is sometimes difficult due to the complexity of biological systems, so further study at the cellular level is required to fully characterize the effects of gold nanoparticles with ionizing radiation.

14 February 2018 in Biomedical Physics & Engineering Express
Verified
Journal Article
Closed access
PDF file
PLPeter Lazarakis
Peter Lazarakis
SISebastien Incerti
Sebastien Incerti
VIVladimir Ivanchenko
Vladimir Ivanchenko
Ioanna KyriakouIoanna Kyriakou
Ioanna Kyriakou
DEDIMITRIS EMFIETZOGLOU
DIMITRIS EMFIETZOGLOU
ARAnatoly B Rozenfeld
Anatoly B Rozenfeld
Monte Carlo methods apply various physical models, either condensed history (CH) or track structure (TS), to simulate the passage of radiation through matter. Both CH and TS models continue to be applied to radiation dosimetry investigations on a micro and nano scale. However, as there has been no systematic comparison of the use of these models for such applications there can be no quantification of the uncertainty that is being introduced by the choice of physics model. A comparison of CH and TS models available in Geant4, along with a quantification of the differences in calculated quantities on a micro and nano scale, has been undertaken in this study. A sphere of liquid water was simulated, with an incident beam of monoenergetic electrons with kinetic energy between 50 eV and 10 keV. The energy deposition (typical of microdosimetry) and number of ionisations (typical of nanodosimetry), per incident particle, were recorded in a water sphere with diameter varying between 1 nm and 1 m. The simulations were repeated using the following physics packages: Livermore (CH), Penelope (CH) and Geant4-DNA (TS). Results indicated that substantial differences were present between calculated physical quantities, depending on the physics model, target diameter and ratio of the target diameter and mean track length of the incident electron. In the case of the smallest targets, the calculated energy deposition was higher when using the CH models, while the number of ionisations was typically underestimated. In larger targets the energy deposition was in good agreement for all physics models, however the number of ionisations was significantly underestimated by the CH approach, in some cases by almost two orders of magnitude. Regarding CH models, the parameter that had the greatest impact on the results was found to be the threshold of production of secondary particles; when this was minimised the CH and TS results showed the best agreement.