Jacques Balosso

Prof. Jacques Balosso


Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 July 2004 in British Journal of Cancer
Verified
Journal Article
Open access
PDF file
SCStéphanie Corde
Stéphanie Corde
AJA Joubert
A Joubert
JAJ F Adam
J F Adam
ACA M Charvet
A M Charvet
JBJ F Le Bas
J F Le Bas
JBJacques Balosso
Jacques Balosso
This study was designed to experimentally evaluate the optimal X-ray energy for increasing the radiation energy absorbed in tumours loaded with iodinated compounds, using the photoelectric effect. SQ20B human cells were irradiated with synchrotron monochromatic beam tuned at 32.8, 33.5, 50 and 70 keV. Two cell treatments were compared to the control: cells suspended in 10 mg ml−1 of iodine radiological contrast agent or cells pre-exposed with 10 μM of iodo-desoxyuridine (IUdR) for 48 h. Our radiobiological end point was clonogenic cell survival. Cells irradiated with both iodine compounds exhibited a radiation sensitisation enhancement. Moreover, it was energy dependent, with a maximum at 50 keV. At this energy, the sensitisation calculated at 10% survival was equal to 2.03 for cells suspended in iodinated contrast agent and 2.60 for IUdR. Cells pretreated with IUdR had higher sensitisation factors over the energy range than for those suspended in iodine contrast agent. Also, their survival curves presented no shoulder, suggesting complex lethal damages from Auger electrons. Our results confirm the existence of the 50 keV energy optimum for a binary therapeutic irradiation based on the presence of stable iodine in tumours and an external irradiation. Monochromatic synchrotron radiotherapy concept is hence proposed for increasing the differential effect between healthy and cancerous tissue irradiation.

1 August 2017 in British Journal of Radiology
Verified
Journal Article
Open access
ESElisabeth Schültke
Elisabeth Schültke
JBJacques Balosso
Jacques Balosso
TBThomas Breslin
Thomas Breslin
Guido CavalettiGuido Cavaletti
Guido Cavaletti
Valentin DjonovValentin Djonov
Valentin Djonov
JLJean Albert Laissue
Jean Albert Laissue
Microbeam irradiation is spatially fractionated radiation on a micrometer scale. Microbeam irradiation with therapeutic intent has become known as microbeam radiation therapy (MRT). The basic concept of MRT was developed in the 1980s, but it has not yet been tested in any human clinical trial, even though there is now a large number of animal studies demonstrating its marked therapeutic potential with an exceptional normal tissue sparing effect. Furthermore, MRT is conceptually similar to macroscopic grid based radiation therapy which has been used in clinical practice for decades. In this review, the potential clinical applications of MRT are analysed for both malignant and non-malignant diseases.

18 September 2014 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
ACAbdulhamid Chaikh
Abdulhamid Chaikh
JGJean-Yves Giraud
Jean-Yves Giraud
EPEmmanuel Perrin
Emmanuel Perrin
JBJean-Pierre Bresciani
Jean-Pierre Bresciani
JBJacques Balosso
Jacques Balosso
Novel irradiation techniques are continuously introduced in radiotherapy to optimize the accuracy, the security and the clinical outcome of treatments. These changes could raise the question of discontinuity in dosimetric presentation and the subsequent need for practice adjustments in case of significant modifications. This study proposes a comprehensive approach to compare different techniques and tests whether their respective dose calculation algorithms give rise to statistically significant differences in the treatment doses for the patient. Statistical investigation principles are presented in the framework of a clinical example based on 62 fields of radiotherapy for lung cancer. The delivered doses in monitor units were calculated using three different dose calculation methods: the reference method accounts the dose without tissues density corrections using Pencil Beam Convolution (PBC) algorithm, whereas new methods calculate the dose with tissues density correction for 1D and 3D using Modified Batho (MB) method and Equivalent Tissue air ratio (ETAR) method, respectively. The normality of the data and the homogeneity of variance between groups were tested using Shapiro-Wilks and Levene test, respectively, then non-parametric statistical tests were performed. Specifically, the dose means estimated by the different calculation methods were compared using Friedman’s test and Wilcoxon signed-rank test. In addition, the correlation between the doses calculated by the three methods was assessed using Spearman’s rank and Kendall’s rank tests. The Friedman’s test showed a significant effect on the calculation method for the delivered dose of lung cancer patients (p <0.001). The density correction methods yielded to lower doses as compared to PBC by on average (−5 ± 4.4 SD) for MB and (−4.7 ± 5 SD) for ETAR. Post-hoc Wilcoxon signed-rank test of paired comparisons indicated that the delivered dose was significantly reduced using density-corrected methods as compared to the reference method. Spearman’s and Kendall’s rank tests indicated a positive correlation between the doses calculated with the different methods. This paper illustrates and justifies the use of statistical tests and graphical representations for dosimetric comparisons in radiotherapy. The statistical analysis shows the significance of dose differences resulting from two or more techniques in radiotherapy.

1 December 2002 in Radiation Research
Verified
Journal Article
Closed access
PDF file
SCS. Corde
S. Corde
MBM. C. Biston
M. C. Biston
HEH. Elleaume
H. Elleaume
FEF. Estève
F. Estève
ACA. M. Charvet
A. M. Charvet
JBJacques Balosso
Jacques Balosso
Corde, S., Biston, M. C., Elleaume, H., Estève, F., Charvet, A. M., Joubert, A., Ducros, V., Bohic, S., Simionovici, A., Brochard, T., Nemoz, C., Renier, Troprès, I., Fiedler, S., Bravin, A., M., Thomlinson, W., Le Bas, J. F. and Balosso, J. Lack of Cell Death Enhancement after Irradiation with Monochromatic Synchrotron X Rays at the K-Shell Edge of Platinum Incorporated in Living SQ20B Human Cells as cis-Diamminedichloroplatinum (II). Radiat. Res. 158, 763–770 (2002).In this paper we describe the results of experiments using synchrotron radiation to trigger the Auger effect in living human cancer cells treated with a widely used chemotherapy drug: cis-diamminedichloroplatinum (II) (cisplatin). The experiments were carried out at the ID17 beamline of the European Synchrotron Radiation Facility, which produces a high-fluence monochromatic beam that is adjustable from 20 to 80 keV. Cisplatin was chosen as the carrier of platinum atoms in the cells because of its alkylating-like activity and the irradiation was done with monochromatic beams above and below the platinum K-shell edge (78.39 keV). Cell survival curves were comparable with those obtained for the same cells under conventional irradiation conditions. At a low dose of cisplatin (0.1 μM, 48 h), no difference was seen in survival when the cells were irradiated above and below the K-shell edge of platinum. Higher cisplatin concentrations were investigated to enhance the cellular platinum content. The results with 1 μM cisplatin for 12 h showed no difference when the cells were irradiated with beams above or below the platinum K-shell edge with the exception of the higher cell death resulting from drug toxicity. The intracellular content of platinum was significant, as measured macroscopically by inductively coupled plasma mass spectrometry. Its subcellular localization and particularly its presence in the cell nucleus were verified by microscopic synchrotron X-ray fluorescence. This was the first known attempt at K-shell edge photon activation of stable platinum in living cells with a platinum complex used for chemotherapy. Its evident toxicity in these cells leads us to put forth the hypothesis that cisplatin toxicity can mask the enhancement of cell death induced by the irradiation above the K-shell edge. However, K-shell edge photon activation of stable elements provides a powerful technique for the understanding of the biological effects of Auger processes. Further avenues of development are discussed.

29 July 2024 in Cancers
Verified
Journal Article
Open access
PDF file
LELaura Eling
Laura Eling
SKSamy Kefs
Samy Kefs
SKSarvenaz Keshmiri
Sarvenaz Keshmiri
JBJacques Balosso
Jacques Balosso
SCSusan Calvet
Susan Calvet
RSRaphael Serduc
Raphael Serduc
Synchrotron Microbeam Radiation Therapy (MRT) has repeatedly proven its superiority compared with conventional radiotherapy for glioma control in preclinical research. The clinical transfer phase of MRT has recently gained momentum; seven dogs with suspected glioma were treated under clinical conditions to determine the feasibility and safety of MRT. We administered a single fraction of 3D-conformal, image-guided MRT. Ultra-high-dose rate synchrotron X-ray microbeams (50 µm-wide, 400 µm-spaced) were delivered through five conformal irradiation ports. The PTV received ~25 Gy peak dose (within microbeams) per port, corresponding to a minimal cumulated valley dose (diffusing between microbeams) of 2.8 Gy. The dogs underwent clinical and MRI follow-up, and owner evaluations. One dog was lost to follow-up. Clinical exams of the remaining six dogs during the first 3 months did not indicate radiotoxicity induced by MRT. Quality of life improved from 7.3/10 [±0.7] to 8.9/10 [±0.3]. Tumor-induced seizure activity decreased significantly. A significant tumor volume reduction of 69% [±6%] was reached 3 months after MRT. Our study is the first neuro-oncologic veterinary trial of 3D-conformal Synchrotron MRT and reveals that MRT does not induce acute to subacute radiotoxicity in normal brain tissues. MRT improves quality of life and leads to remarkable tumor volume reduction despite low valley dose delivery. This trial is an essential step towards the forthcoming clinical application of MRT against deep-seated human brain tumors.

1 December 2004 in Radiotherapy and Oncology
Verified
Journal Article
Closed access
JBJacques Balosso
Jacques Balosso