Shigeru Tada

Dr. Shigeru Tada

Department of Applied Physics, National Defense Academy, Kanagawa 239-8686, Japan

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2017 in Biomicrofluidics
Verified
Journal Article
Closed access
Shigeru TadaShigeru Tada
Shigeru Tada
MHMasako Hayashi
Masako Hayashi
MEMasanori Eguchi
Masanori Eguchi
ATAkira Tsukamoto
Akira Tsukamoto
We propose a novel, high-performance dielectrophoretic (DEP) cell-separation flow chamber with a parallel-plate channel geometry. The flow chamber, consisting of a planar electrode on the top and an interdigitated-pair electrode array at the bottom, was developed to facilitate the separation of cells by creating a nonuniform AC electric field throughout the volume of the flow chamber. The operation and performance of the device were evaluated using live and dead human epithermal breast (MCF10A) cells. The separation dynamics of the cell suspension in the flow chamber was also investigated by numerically simulating the trajectories of individual cells. A theoretical model to describe the dynamic cell behavior under the action of DEP, including dipole-dipole interparticle, viscous, and gravitational forces, was developed. The results demonstrated that the live cells traveling through the flow chamber congregated into sites where the electric field gradient was minimal, in the middle of the flow stream slightly above the centerlines of the grounded electrodes at the bottom. Meanwhile, the dead cells were trapped on the edges of the high-voltage electrodes at the bottom. Cells were thus successfully separated with a remarkably high separation ratio (∼98%) at the appropriately tuned field frequency and applied voltage. The numerically predicted behavior and spatial distribution of the cells during separation also showed good agreement with those observed experimentally.

24 June 2010 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
Shigeru TadaShigeru Tada
Shigeru Tada
This study investigates the oxygen mass transport in the region around the human carotid bifurcation, particularly addressing the effects of bifurcation geometry and pulsatile blood flow on the oxygen transport between the blood flow and artery wall tissue, coupled with the metabolic oxygen consumption and oxygen diffusion in the artery wall tissue. The temporal variations and spatial distributions of the oxygen tension are predicted quantitatively using a geometric model of the human carotid bifurcation and realistic blood flow waveforms. Results reveal that the flow separation at the outside wall of the sinus of the internal carotid artery (ICA) can markedly alter the flow pattern, oxygen tension and the oxygen wall flux. Results also clarify that the flow unsteadiness has a secondary effect on the oxygen tension inside the wall. The non-dimensional oxygen flux, the Sherwood number Sh, at the outside wall of the ICA sinus, takes markedly lower values of about 45 than at other sites because the rates of oxygen transport by the convective flow are reduced at the outside wall of the ICA sinus. The transverse distributions of the oxygen tension inside the artery wall show parabolic profiles having minima in the middle of the wall thickness, with the lowest value of 35 mmHg. These predicted distributions of the oxygen tension inside the wall closely resemble those obtained from experiments. The results demonstrate that hypoxic zones appear inside the artery walls at locations where atherosclerotic lesions are prone to develop.

23 January 2019 in Electrophoresis
Verified
Journal Article
Closed access
PDF file
Shigeru TadaShigeru Tada
Shigeru Tada
MEMasanori Eguchi
Masanori Eguchi
KOKohei Okano
Kohei Okano

2 August 2022 in Fluids
Verified
Journal Article
Open access
PDF file
Shigeru TadaShigeru Tada
Shigeru Tada
YSYoshinori Seki
Yoshinori Seki
Cell separation techniques based on dielectrophoresis are of high interest as an effective method of performing cell separation non-invasively on cells. However, dielectrophoresis devices have the problem that cells in the device are exposed to a high-temperature environment due to the generation of Joule heat caused by high-voltage application and dielectric-loss heat when the applied voltage is AC voltage. There is concern that the heat generated in the device may affect cell viability, cell cycle and apoptosis induction. In this study, the temperature field inside the dielectrophoretic cell separation device was experimentally and numerically investigated. The temperature rise at the bottom of the flow channel in the device was measured using the LIF method, and the thermofluidal behavior of the device was numerically simulated by adopting a heat generation model that takes the Joule and dielectric-loss heating into account in the energy equation. The temperature rise in the device was evaluated and the effect of the heat generation on cells in the device is discussed.

4 November 2024 in Sensors
Verified
Journal Article
Open access
PDF file
YSYoshinori Seki
Yoshinori Seki
Shigeru TadaShigeru Tada
Shigeru Tada
Technologies for rapid and high-throughput separation of rare cells from large populations of other types of cells have recently attracted much attention in the field of bioengineering. Among the various cell separation technologies proposed in the past, dielectrophoresis has shown particular promise because of its preciseness of manipulation and noninvasiveness to cells. However, one drawback of dielectrophoresis devices is that their application of high voltage generates Joule heat that exposes the cells within the device to high temperatures. To further explore this problem, this study investigated the temperature field in a previously developed cell separation device in detail. The temperature rise at the bottom of the microfluidic channel in the device was measured using a micro-LIF method. Moreover, the thermofluidic behavior of the cell separation device was numerically investigated by adopting a heat generation model that takes the electric-field-dependent heat generation term into account in the energy equation. Under the operating conditions of the previously developed cell separation device, the experimentally obtained temperature rise in the device was approximately 20 °C, and the numerical simulation results generally agreed well. Next, parametric calculations were performed with changes in the flow rate of the cell sample solution and the solution conductivity, and a temperature increase of more than 40 °C was predicted. The results demonstrated that an increase in temperature within the cell separation device may have a significant impact on the physiological functions of the cells, depending on the operating conditions of the device.

1 May 2016 in Biomicrofluidics
Verified
Journal Article
Closed access
PDF file
Shigeru TadaShigeru Tada
Shigeru Tada
ANArisa Nakanishi
Arisa Nakanishi
MEMasanori Eguchi
Masanori Eguchi
KOKengo Ochi
Kengo Ochi
MBMegumi Baba
Megumi Baba
ATAkira Tsukamoto
Akira Tsukamoto
The variability in cell response to AC electric fields is selective enough to separate not only the cell types but also the activation states of similar cells. In this work, we use dielectrophoresis (DEP), which exploits the differences in the dielectric properties of cells, to separate nonviable and viable cells. A parallel-plate DEP device consisting of a bottom face with an array of micro-fabricated interdigitated electrodes and a top face with a plane electrode was proposed to facilitate the separation of cells by creating a nonuniform electric field throughout the flow channel. The operation and performance of the device were evaluated using live and dead yeast cells as model biological particles. Further, numerical simulations were conducted for the cell suspensions flowing in a channel with a nonuniform AC electric field, modeled on the basis of the equation of motion of particles, to characterize the separation efficiency by changing the frequency of applied AC voltage. Results demonstrated that dead cells traveling through the channel were focused onto a site around the minimum electric field gradient in the middle of the flow stream, while live cells were trapped on the bottom face. Cells were thus successfully separated under the appropriately tuned frequency of 1 MHz. Predictions showed good agreement with the observation. The proposed DEP device provides a new approach to, for instance, hematological analysis or the separation of different cancer cells for application in circulating tumor cell identification.