Technologies for rapid and high-throughput separation of rare cells from large populations of other types of cells have recently attracted much attention in the field of bioengineering. Among the various cell separation technologies proposed in the past, dielectrophoresis has shown particular promise because of its preciseness of manipulation and noninvasiveness to cells. However, one drawback of dielectrophoresis devices is that their application of high voltage generates Joule heat that exposes the cells within the device to high temperatures. To further explore this problem, this study investigated the temperature field in a previously developed cell separation device in detail. The temperature rise at the bottom of the microfluidic channel in the device was measured using a micro-LIF method. Moreover, the thermofluidic behavior of the cell separation device was numerically investigated by adopting a heat generation model that takes the electric-field-dependent heat generation term into account in the energy equation. Under the operating conditions of the previously developed cell separation device, the experimentally obtained temperature rise in the device was approximately 20 °C, and the numerical simulation results generally agreed well. Next, parametric calculations were performed with changes in the flow rate of the cell sample solution and the solution conductivity, and a temperature increase of more than 40 °C was predicted. The results demonstrated that an increase in temperature within the cell separation device may have a significant impact on the physiological functions of the cells, depending on the operating conditions of the device.
Dielectrophoresis (DEP) cell separation technology is an effective means of separating target cells which are only marginally present in a wide variety of cells. To develop highly efficient cell separation devices, detailed analysis of the nonuniform electric field’s intensity distribution within the device is needed, as it affects separation performance. Here we analytically expressed the distributions of the electric field and DEP force in a parallel-plate cell separation DEP device by employing electrostatic analysis through the Fourier series method. The solution was approximated by extrapolating a novel approximate equation as a boundary condition for the potential between adjacent fingers of interdigitated electrodes and changing the underlying differential equation into a solvable form. The distributions of the potential and electric fields obtained by the analytical solution were compared with those from numerical simulations using finite element method software to verify their accuracy. As a result, it was found that the two agreed well, and the analytical solution was obtained with good accuracy. Three-dimensional fluorescence imaging analysis was performed using live non-tumorigenic human mammary (MCF10A) cells. The distribution of cell clusters adsorbed on the interdigitated electrodes was compared with the analytically obtained distribution of the DEP force, and the mechanism underlying cell adsorption on the electrode surface was discussed. Furthermore, parametric analysis using the width and spacing of these electrodes as variables revealed that spacing is crucial for determining DEP force. The results suggested that for cell separation devices using interdigitated electrodes, optimization by adjusting electrode spacing could significantly enhance device performance.
Technologies for rapid and high-throughput separation of rare cells from large populations of other types of cells have recently attracted much attention in the field of bioengineering. Among the various cell separation technologies proposed in the past, dielectrophoresis has shown particular promise because of its preciseness of manipulation and noninvasiveness to cells. However, one drawback of dielectrophoresis devices is that their application of high-voltage generates Joule heat that exposes the cells within the device to high temperature. To further explore this problem, this study investigated the temperature field in the previously developed cell separation device in detail. The temperature rise at the bottom of the microfluidic channel in the device was measured using a micro-LIF method. Moreover, the thermofluidic behavior of the cell separation device was numerically investigated by adopting a heat generation model that takes the electric-field-dependent heat generation term into account in the energy equation. Under the operating conditions of the previously developed cell separation device, the experimentally obtained temperature rise in the device was approximately 20 ℃, and the numerical simulation results generally agreed well. Next, parametric calculations were performed with changes in the flow rate of the cell sample solution and the solution conductivity, and a temperature increase of more than 40 ℃ was predicted. The results demonstrated that an increase in temperature within the cell separation device may have a significant impact on the physiological functions of the cells, depending on the operating conditions of the device.
Dielectrophoresis (DEP) cell-separation technology is an effective means of separating rare cells. To develop highly efficient cell-separation devices, detailed analysis of the nonuniform electric field’s intensity distribution within the device is needed, as it affects separation performance. Here we analytically expressed the distributions of the electric field and DEP force in a parallel-plate cell-separation DEP device by employing electrostatic analysis through the Fourier series method. The solution was approximated by extrapolating a novel approximate equation as a boundary condition for the potential between adjacent fingers of interdigitated electrodes and changed the underlying differential equation into a solvable form. The distributions of the potential and electric fields obtained by the analytical solution were compared with those from numerical simulations using finite element method software to verify their accuracy. The results showed excellent agreement. Three-dimensional fluorescence imaging analysis used live non-tumorigenic human mammary (MCF10A) cells. The distribution of cell clusters adsorbed on the interdigitated electrodes was compared with the analytically obtained distribution of the DEP force, and the mechanism underlying cell adsorption on the electrode surface was discussed. Furthermore, parametric analysis using the width and spacing of these electrodes as variables revealed that spacing is crucial for determining DEP force. The results showed that, by optimizing cell-separation devices using interdigitated electrodes, adjusting electrode spacing significantly enhances device performance.