Luis Lopez-Montero

Prof. Luis Lopez-Montero


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 September 2021 in Axioms
Verified
Journal Article
Open access
PDF file
ARAndrés Romero-Arellano
Andrés Romero-Arellano
Ernesto Moya-AlborErnesto Moya-Albor
Ernesto Moya-Albor
Jorge BrievaJorge Brieva
Jorge Brieva
ICIvan Cruz-Aceves
Ivan Cruz-Aceves
Juan Gabriel Avina-CervantesJuan Gabriel Avina-Cervantes
Juan Gabriel Avina-Cervantes
LLLuis Lopez-Montero
Luis Lopez-Montero
In this work, a new medical image encryption/decryption algorithm was proposed. It is based on three main parts: the Jigsaw transform, Langton’s ant, and a novel way to add deterministic noise. The Jigsaw transform was used to hide visual information effectively, whereas Langton’s ant and the deterministic noise algorithm give a reliable and secure approach. As a case study, the proposal was applied to high-resolution retinal fundus images, where a zero mean square error was obtained between the original and decrypted image. The method performance has been proven through several testing methods, such as statistical analysis (histograms and correlation distributions), entropy computation, keyspace assessment, robustness to differential attack, and key sensitivity analysis, showing in each one a high security level. In addition, the method was compared against other works showing a competitive performance and highlighting with a large keyspace (>1×101,134,190.38). Besides, the method has demonstrated adequate handling of high-resolution images, obtaining entropy values between 7.999988 and 7.999989, an average Number of Pixel Change Rate (NPCR) of 99.5796%±0.000674, and a mean Uniform Average Change Intensity (UACI) of 33.4469%±0.00229. In addition, when there is a small change in the key, the method does not give additional information to decrypt the image.

18 April 2022 in Mathematics
Verified
Journal Article
Open access
PDF file
DADora Elisa Alvarado-Carrillo
Dora Elisa Alvarado-Carrillo
ICIvan Cruz-Aceves
Ivan Cruz-Aceves
MHMartha A. Hernández-González
Martha A. Hernández-González
LLLuis Lopez-Montero
Luis Lopez-Montero
The Major Temporal Arcade (MTA) is a critical component of the retinal structure that facilitates clinical diagnosis and monitoring of various ocular pathologies. Although recent works have addressed the quantitative analysis of the MTA through parametric modeling, their efforts are strongly based on an assumption of symmetry in the MTA shape. This work presents a robust method for the detection and piecewise parametric modeling of the MTA in fundus images. The model consists of a piecewise parametric curve with the ability to consider both symmetric and asymmetric scenarios. In an initial stage, multiple models are built from random blood vessel points taken from the blood-vessel segmented retinal image, following a weighted-RANSAC strategy. To choose the final model, the algorithm extracts blood-vessel width and grayscale-intensity features and merges them to obtain a coarse MTA probability function, which is used to weight the percentage of inlier points for each model. This procedure promotes selecting a model based on points with high MTA probability. Experimental results in the public benchmark dataset Digital Retinal Images for Vessel Extraction (DRIVE), for which manual MTA delineations have been prepared, indicate that the proposed method outperforms existing approaches with a balanced Accuracy of 0.7067, Mean Distance to Closest Point of 7.40 pixels, and Hausdorff Distance of 27.96 pixels, while demonstrating competitive results in terms of execution time (9.93 s per image).

29 January 2023 in Axioms
Verified
Journal Article
Open access
PDF file
JSJosé Alfredo Soto-Álvarez
José Alfredo Soto-Álvarez
ICIvan Cruz-Aceves
Ivan Cruz-Aceves
AAArturo Hernández Aguirre
Arturo Hernández Aguirre
MHMartha A. Hernández-González
Martha A. Hernández-González
LLLuis Lopez-Montero
Luis Lopez-Montero
SSSergio Solorio
Sergio Solorio
Within eye diseases, diabetic retinopathy and retinopathy of prematurity are considered one of the main causes of blindness in adults and children. In order to prevent the disease from reaching such an extreme, a timely diagnosis and effective treatment must be applied. Until now, the way to verify the state of the retina has been to make qualitative observations of fundus images, all carried out by an ophthalmological specialist; however, this is totally restricted to their experience, and some changes in the vascular structure of the retina could be omitted, in addition to the fact that very high resolution images would be needed to be able to detect significant changes. Accordingly, with the help of computational tools, this diagnostic/monitoring process can be improved. This paper presents a novel strategy for the modeling of the MTA by using an estimation of distribution algorithm (EDA) based on the probability density function in order to determine the coefficients and parameters (α,β) of a Jacobi polynomial series. A model using polynomials is the novel aspect of this work since in the literature there are no models of the MTA of this type, in addition to seeking to better cover the profile of the retinal vein. According to the experimental results, the proposed method presents the advantage to achieve superior performance in terms of the mean distance to the closest point (4.34 pixels), and the Hausdorff distance (14.43 pixels) with respect to different state-of-the-art methods of the numerical modeling of the retina, using the DRIVE database of retinal fundus images with a manual delineation of the MTA performed by an specialist.