Taechang An

Prof. Taechang An


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 October 2018 in Materials
Verified
Journal Article
Open access
PDF file
GKGeon Hwee Kim
Geon Hwee Kim
KKKanghyun Kim
Kanghyun Kim
ELEunji Lee
Eunji Lee
TATaechang An
Taechang An
WCWooSeok Choi
WooSeok Choi
JSJung Hwal Shin
Jung Hwal Shin
Brain‒machine interface (BMI) is a promising technology that looks set to contribute to the development of artificial limbs and new input devices by integrating various recent technological advances, including neural electrodes, wireless communication, signal analysis, and robot control. Neural electrodes are a key technological component of BMI, as they can record the rapid and numerous signals emitted by neurons. To receive stable, consistent, and accurate signals, electrodes are designed in accordance with various templates using diverse materials. With the development of microelectromechanical systems (MEMS) technology, electrodes have become more integrated, and their performance has gradually evolved through surface modification and advances in biotechnology. In this paper, we review the development of the extracellular/intracellular type of in vitro microelectrode array (MEA) to investigate neural interface technology and the penetrating/surface (non-penetrating) type of in vivo electrodes. We briefly examine the history and study the recently developed shapes and various uses of the electrode. Also, electrode materials and surface modification techniques are reviewed to measure high-quality neural signals that can be used in BMI.

28 July 2021 in Polymers
Verified
Journal Article
Open access
PDF file
HOHyeonSeok Oh
HyeonSeok Oh
CLChungHyeon Lee
ChungHyeon Lee
NKNa Kyoung Kim
Na Kyoung Kim
TATaechang An
Taechang An
Geon Hwee KimGeon Hwee Kim
Geon Hwee Kim
Skin is the largest sensory organ and receives information from external stimuli. Human body signals have been monitored using wearable devices, which are gradually being replaced by electronic skin (E-skin). We assessed the basic technologies from two points of view: sensing mechanism and material. Firstly, E-skins were fabricated using a tactile sensor. Secondly, E-skin sensors were composed of an active component performing actual functions and a flexible component that served as a substrate. Based on the above fabrication processes, the technologies that need more development were introduced. All of these techniques, which achieve high performance in different ways, are covered briefly in this paper. We expect that patients’ quality of life can be improved by the application of E-skin devices, which represent an applied advanced technology for real-time bio- and health signal monitoring. The advanced E-skins are convenient and suitable to be applied in the fields of medicine, military and environmental monitoring.

9 March 2020 in RSC Advances
Verified
Journal Article
Open access
PDF file
GKGeon Hwee Kim
Geon Hwee Kim
HWHyeonsu Woo
Hyeonsu Woo
SKSuhyeon Kim
Suhyeon Kim
TATaechang An
Taechang An
GLGeunbae Lim
Geunbae Lim
Flexible transparent electrodes (FTEs) are widely used in a variety of applications, including flexible displays and wearable devices. Important factors in FTE design include active control of electrical sheet resistance, optical transparency and mechanical flexibility. Because these factors are inversely proportional to one another, it is essential to develop a technique that maintains flexibility while actively controlling the sheet resistance and transparency for a variety of applications. This research presents a new method for fabricating transparent electrodes on flexible polyimide films using electrospinning and copper electroless deposition methods. A flat metal network-based electrode without contact resistance was fabricated by heat treatment and electroless deposition onto the electrospun seed layer. The fabricated FTEs exhibited a transparency exceeding 80% over the entire visible light range and a sheet resistance of less than 10.0 Ω sq−1. Due to the heat treatment process, the adhesion between the metal network and the substrate was superior to other electrospinning-based transparent electrodes. Applicable to the large-area manufacturing process, the standard deviation of the network density of the fabricated large-area FTE was about 1%. This study does not require the polymer casting technique and has further advantages for mass production of electrodes and application to various fields.

30 May 2017 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
GKGeon Hwee Kim
Geon Hwee Kim
TATaechang An
Taechang An
GLGeunbae Lim
Geunbae Lim

12 January 2018 in Advanced Materials Interfaces
Verified
Journal Article
Closed access
PDF file
GKGeon Hwee Kim
Geon Hwee Kim
HNHyoryung Nam
Hyoryung Nam
WCWooSeok Choi
WooSeok Choi
TATaechang An
Taechang An
GLGeunbae Lim
Geunbae Lim

28 November 2017 in Discover Nano
Verified
Journal Article
Open access
PDF file
WCWooSeok Choi
WooSeok Choi
GKGeon Hwee Kim
Geon Hwee Kim
JSJung Hwal Shin
Jung Hwal Shin
GLGeunbae Lim
Geunbae Lim
TATaechang An
Taechang An
We report a simple method for electrospinning polymers onto flexible, insulating substrates by controlling the wettability of the substrate surface. Water