Terahertz (THz) frequency modulated continuous wave (FMCW) technology is a means of nondestructive testing. The signal’s nonlinearity is an unavoidable problem in the daily application of THz FMCW technology. The signal’s nonlinearity will lead to the spectrum broadening of the FMCW’s beat frequency (BF) signal, which degrades the range resolution and result in distance-measuring error. Traditional methods require additional hardware or require a lot of computation, which are not conducive to the miniaturization of the system and real-time measurement. A novel method for correcting the nonlinear error of THz FMCW technology has been proposed and demonstrated in this article. In the proposed method, the windowed Fourier transform (WFT) is introduced to estimate the BF corresponding to the measured target, according to the linearity distribution of voltage-controlled oscillator (VCO). In this way, the measured target's BF can be accurately estimated from the unprocessed BF signal with a poor linearity. From the estimated BF of the reference target, the non-linear compensation coefficients are calculated. With the non-linear compensation coefficients, the non-linearity of the output BF signal can be calibrated. The results of simulations and experiments show that the proposed method allows the range resolution of an FMCW system to reach the theoretical limit.
Ultra-wide-band (UWB) radar technology is a contactless signal detection technology. The UWB technology can be used for the clinical medical monitoring of the human heartbeat and respiration. In this paper, a novel algorithm is proposed to estimate heart rate (HR) and respiratory rate (RR) depending on the received UWB radar signal. The proposed algorithm initially applies Singular Spectrum Analysis (SSA) to remove noise from the received UWB radar signal, and then applies Variational Mode Decomposition (VMD) to effectively separate the respiratory and heartbeat components. To address the issue of heartbeat components being susceptible to harmonic and inter-modulation components interference, a double fuzzy logic estimation is implemented to achieve robust real-time extraction of heart rate. In this paper, extensive experiments are conducted at various distances and angles. The experimental results of the SSA-VMD-Double-Fuzzy-Logic (SVDF) method have been compared with other methods, demonstrating its effectiveness and the advantages of the SVDF proposed in this paper.
This paper presents a 220 GHz × 2 amplifier–doubler chain composed of a rat-race balun, a 6-stage driver amplifier, and a frequency doubler. The presented amplifier–doubler chain was fabricated in commercial 40 nm bulk CMOS technology. The maximum cutoff frequency fmax for the NMOS transistor produced by this manufacturing process was 290 GHz. The saturation output power of the six-stage driver amplifier at 110 GHz was 11.5 dBm. The transistor of the frequency doubler consisted of a single-row interleaved Poly-Diffusion Contact balancing structure. Theoretically, the single-row interleaved Poly-Diffusion Contact balancing structure was able to effectively avoid parasitic components. The simulated results demonstrate that the presented structure achieves a higher output than the conventional designs. Based on these measured results, the presented amplifier–doubler chain provides a peak output power of 7.9 dBm at 200 GHz and a 3-dB bandwidth of 30 GHz. Based on the comparison with other reported results, the presented amplifier–doubler chain provides the highest output power among reported frequency doublers fabricated in CMOS technology.
The terahertz (THz) rotation mirror imaging system is an alternative to the THz array imaging system. A THz rotation mirror imaging system costs less than a THz array imaging system, while the imaging speed of a THz rotation mirror imaging system is much higher than the imaging speed of a THz raster-scan imaging system under the same hardware conditions. However, there is some distortion in the THz image from the THz rotation mirror imaging system. The distortion, which makes images from the THz rotation mirror imaging system difficult to identify, results from the imaging principle of the THz rotation mirror imaging system. In this article, a method based on the scale-recurrent network (SRN) is put in place to correct the distortion. A comparison between distorted THz images and corrected images shows that the proposed method significantly increases the structural similarity between the THz images and the samples.