This paper discusses the wind loads for designing vaulted free roofs based on a wind tunnel experiment, in which the wind force coefficients for the main wind force resisting system and the peak wind force coefficients for cladding are considered. The focus is on the dynamic load effects of fluctuating wind pressures on the wind force coefficients. Wind pressure distributions on the top and bottom surfaces were measured in a turbulent boundary layer. The results indicated that the distributions of wind force coefficients changed significantly with wind direction. Then, the wind direction providing the maximum load effect on the structural frame was detected from a dynamic response analysis using the time histories of wind pressure coefficients. In the analysis, the focus was on the bending moment at the windward column base and the axial force in the leeward column as the most important load effects. The LRC method proposed by Kasperski was employed for evaluating the equivalent static wind force coefficients providing the maximum load effects. Based on the results, a model of design wind force coefficient was proposed in the framework of the conventional gust effect factor approach. Finally, positive and negative peak wind force coefficients for designing the cladding were proposed based on the most critical maximum and minimum peak wind force coefficients among all wind directions.
19 October 2007 in Scandinavian Journal of Immunology
No licensed vaccines are available to protect against parainfluenza virus type 3 (PIV3), a significant health risk for infants. In search of a safe vaccine, we used an alphavirus‐based chimeric vector, consisting of Sindbis virus (SIN) structural proteins and Venezuelan equine encephalitis virus (VEE) replicon RNA, expressing the PIV3 hemagglutinin‐neuraminidase (HN) glycoprotein (VEE/SIN‐HN). We compared different routes of intramuscular (IM), intranasal (IN), or combined IN and IM immunizations with VEE/SIN‐HN in hamsters. Six months after the final immunization, all hamsters were protected against live PIV3 IN challenge in nasal turbinates and lungs. This protection appeared to correlate with antibodies in serum, nasal turbinates and lungs. This is the first report demonstrating mucosal protection against PIV3 for an extended time following immunizations with an RNA replicon delivery system.
Many residential houses in Japan have hip roofs with pitches ranging from 20° to 30°. Recently, roof-mounted photovoltaic (PV) panels have become popular all over the world for environmental conservation. The design of PV systems in Japan is usually based on the Japanese Industrial Standard (JIS) C 8955 (2017). However, the standard does not provide wind force coefficients for PV panels installed near roof edges (up to 0.3 m from the edge) because flow separation at the roof edges causes large up-lift forces on such panels. In this paper, we investigated the wind force coefficients for designing PV panels installed on hip roofs of rectangular and L-shaped low-rise buildings. The roof pitch was set to 25° as a typical value. Rectangular panels were installed almost over the whole roof, including the edge zones. Because the thickness of PV panels and the distance between PV panels and the roof are both as small as several centimeters, it is difficult to make wind tunnel models of PV systems with the same geometric scale as that for buildings. We focused on a numerical simulation using the unsteady Bernoulli equation to estimate the pressures in the space between PV panels and the roof. In the simulation, we used the time histories of wind pressure coefficients on the bare roof, which were measured in a turbulent boundary layer. We propose installing PV panels with small gaps between them along their short sides. The gaps may reduce the wind loads not only on the PV panels but also on the roofing due to pressure equalization. We discuss the optimum gap width from the viewpoint of wind load reduction.