Many residential houses in Japan have hip roofs with pitches ranging from 20° to 30°. Recently, roof-mounted photovoltaic (PV) panels have become popular all over the world for environmental conservation. The design of PV systems in Japan is usually based on the Japanese Industrial Standard (JIS) C 8955 (2017). However, the standard does not provide wind force coefficients for PV panels installed near roof edges (up to 0.3 m from the edge) because flow separation at the roof edges causes large up-lift forces on such panels. In this paper, we investigated the wind force coefficients for designing PV panels installed on hip roofs of rectangular and L-shaped low-rise buildings. The roof pitch was set to 25° as a typical value. Rectangular panels were installed almost over the whole roof, including the edge zones. Because the thickness of PV panels and the distance between PV panels and the roof are both as small as several centimeters, it is difficult to make wind tunnel models of PV systems with the same geometric scale as that for buildings. We focused on a numerical simulation using the unsteady Bernoulli equation to estimate the pressures in the space between PV panels and the roof. In the simulation, we used the time histories of wind pressure coefficients on the bare roof, which were measured in a turbulent boundary layer. We propose installing PV panels with small gaps between them along their short sides. The gaps may reduce the wind loads not only on the PV panels but also on the roofing due to pressure equalization. We discuss the optimum gap width from the viewpoint of wind load reduction.

3 March 2022 in Wind
Verified
Journal Article
Open access
PDF file
Yasushi UEMATSUYasushi UEMATSU
Yasushi UEMATSU
TYTetsuo Yambe
Tetsuo Yambe
AYAtsushi Yamamoto
Atsushi Yamamoto
Many residential houses with sloped roofs are equipped with photovoltaic (PV) systems. In Japan, PV systems are generally designed based on JIS C 8955, which specifies wind force coefficients for designing PV panels. However, no specification is provided to the PV panels installed near the roof edges where high suctions are induced. When installing PV panels in such high-suction zones, we need to evaluate the wind loads on the PV panels appropriately, usually by performing a wind tunnel experiment. However, it is difficult to make wind tunnel models of PV panels with the same geometric scale as that for the building, e.g., 1/100, because the thickness of PV panels and the distance between PV panels and a roof are both several centimeters. Therefore, in the present paper a numerical simulation is applied to the estimation of pressures in the space between the lower surface of PV panels and the roof surface, called “layer pressures”, using the unsteady Bernoulli equation and the time histories of external pressure coefficients obtained from a wind tunnel experiment. An assumption of the weak compressibility of the air and an adiabatic condition is made for predicting the layer pressures from the flow speed through the gaps. The simulation method is validated by a wind tunnel experiment using a model of square-roof building.