The design of adaptive façades as complex systems that dynamically respond to weather conditions and occupants’ demands is rapidly increasing in modern constructions since they are highly energy efficient. Adaptive Dynamic Building Envelopes (ADBEs) exploit the benefits of technologies that manage the energy and mass transfer between building and outdoor environments actively and selectively. There is a wide range of technologies used in the design of ADBEs that differ from one another in terms of user controllability and the level of how active or passive their technologies are. This paper provides a systematic search in literature on the technologies devised in the ADBEs, specifying the most prevalent practices, and highlights the most cutting-edge research approximations. The analysis shows more than half of the studies use photovoltaics (PVs) in their design. Using mechanical ventilation and heat pumps were the next popular choices. Moreover, approximately half of the studies were carried out using simulation methods alone, whereas only 13% of studies couple simulations with experimental work. This highlights a clear gap in coupling digital modeling and simulation software with practical field testing and successful mass production.
This paper introduces a Model Predictive Control (MPC) strategy for the optimal energy management of a district whose buildings are equipped with vertically placed Building Integrated Photovoltaic (BIPV) systems and Battery Energy Storage Systems (BESS). The vertically placed BIPV systems are able to cover larger areas of buildings’ surfaces, as compared with conventional rooftop PV systems, and reach their peak of production during winter and spring, which renders them suitable for energy harvesting especially in urban areas. Driven by both these relative advantages, the proposed strategy aims to maximize the district’s autonomy from the external grid, which is achieved through the cooperation of interactive buildings. Therefore, the major contribution of this study is the management and optimal cooperation of a group of buildings, each of which is equipped with its own system of vertical BIPV panels and BESS, carried out by an MPC strategy. The proposed control scheme consists of three main components, i.e., the forecaster, the optimizer and the district, which interact periodically with each other. In order to quantitatively evaluate the benefits of the proposed MPC strategy and the implementation of vertical BIPV and BESS, a hypothetical five-node distribution network located in Greece for four representative days of the year was examined, followed by a sensitivity analysis to examine the effect of the system configuration on its performance.
Energy consumption reduction and thermal quality improvement constitute two major aspects of building design and/or retrofitting. Following the current energy transition trends, a state-of-the-art solution is the implementation of Adaptive Dynamic Building Envelopes (ADBEs), which are capable of integrating different technologies and components. The purpose of this investigation is to assess the annual performance improvement of two actual building spaces retrofitted with ADBEs, consisting of Building Integrated Photovoltaics (BIPVs), additional thermal insulation, mechanical ventilation system with heat recovery, and solar air heaters (SAHs). Both buildings are pilot sites for the EU Horizon 2020 Plug-n-Harvest project and are located in two rather different climate zones, i.e., Cardiff, Wales, and Grevena, Greece. Moreover, through detailed dynamic modeling with the use of Modelica language, this study attempts to accurately capture all interactions between buildings and all the aforementioned ADBE components. The simulations compared the energy performance and indoor temperature levels in each space before and after the installation of the ADBEs. The results showed that the harvesting of renewable energy through the ADBE system could potentially contribute 60% and 21.8% to the annual electricity and heating load of the space in Cardiff, respectively, and 43.5% to the annual electricity load of the building space in Grevena.