Fernando Martin-Rivera

Dr. Fernando Martin-Rivera

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2020 in Biology of Sport
Verified
Journal Article
Open access
PDF file
Sergio Maroto-IzquierdoSergio Maroto-Izquierdo
Sergio Maroto-Izquierdo
IBIker Javier Bautista
Iker Javier Bautista
FMFernando Martin-Rivera
Fernando Martin-Rivera
This study investigated the post-activation performance enhancements (PAPE) induced by a high-intensity single set of accentuated eccentric isoinertial resistance exercise on vertical jump performance. Twenty physically active male university students performed, in randomized counterbalanced...

1 August 2018 in International Journal of Sports Science & Coaching
Verified
Journal Article
Closed access
Amador Garcia RamosAmador Garcia Ramos
Amador Garcia Ramos
Alejandro Pérez-CastillaAlejandro Pérez-Castilla
Alejandro Pérez-Castilla
FMFernando Martin-Rivera
Fernando Martin-Rivera
The objective of this study was to explore the reliability and concurrent validity of the Velowin optoelectronic system to measure movement velocity during the free-weight back squat exercise. Thirty-one men (age = 27.5 ± 3.2 years; body height = 1.76 ± 0.15 m; body mass: 78.3 ± 7.6 kg) were evaluated in a single session against five different loads (20, 40, 50, 60 and 70 kg) and three velocity variables (mean velocity, mean propulsive velocity and maximum velocity) were recorded simultaneously by a linear velocity transducer (T-Force; gold-standard) and a camera-based optoelectronic system (Velowin). The main findings revealed that (1) the three velocity variables were determined with a high and comparable reliability by both the T-Force and Velowin systems (median coefficient of variation of the five loads: T-Force: mean velocity = 4.25%, mean propulsive velocity = 4.49% and maximum velocity = 3.45%; Velowin: mean velocity = 4.29%, mean propulsive velocity = 4.60% and maximum velocity = 4.44%), (2) the maximum velocity was the most reliable variable when obtained by the T-force (p < 0.05), but no significant differences in the reliability of the variables were observed for the Velowin (p > 0.05) and (3) high correlations were observed for the values of mean velocity (r = 0.976), mean propulsive velocity (r = 0.965) and maximum velocity (r = 0.977) between the T-Force and Velowin systems. Collectively, these results support the Velowin as a reliable and valid system for the measurement of movement velocity during the free-weight back squat exercise.

1 September 2021 in Journal of Science and Medicine in Sport
Verified
Journal Article
Closed access
IBIker Javier Bautista
Iker Javier Bautista
JVJuan Vicente-Mampel
Juan Vicente-Mampel
LVLuis Baraja Vegas
Luis Baraja Vegas
VSVíctor Segarra
Víctor Segarra
FMFernando Martin-Rivera
Fernando Martin-Rivera
BHBas Van Hooren
Bas Van Hooren

1 December 2015 in Journal of Exercise Science & Fitness
Verified
Journal Article
Closed access
SBSebastien Borreani
Sebastien Borreani
Joaquín CalatayudJoaquín Calatayud
Joaquín Calatayud
Juan C ColadoJuan C Colado
Juan C Colado
DMDiego Moya-Nájera
Diego Moya-Nájera
NTN. Travis Triplett
N. Travis Triplett
FMFernando Martin-Rivera
Fernando Martin-Rivera

12 August 2022 in Frontiers in Physiology
Verified
Journal Article
Open access
FMFernando Martin-Rivera
Fernando Martin-Rivera
MBMarco Beato
Marco Beato
VAVicente Alepuz-Moner
Vicente Alepuz-Moner
Sergio Maroto-IzquierdoSergio Maroto-Izquierdo
Sergio Maroto-Izquierdo
Purpose: To propose the concentric linear velocity measurement as a valid method to quantify load and individualise the prescription of flywheel training, we investigated the relationship between inertial load and mean concentric linear velocity (MCLV) during the flywheel squat exercise in a wide spectrum of intensities. In addition, we compared MCLV and subjective rating of perceived exertion (RPE) after each load.Methods: Twenty-five physically active men volunteered for this study (26.5 ± 2.9 years, 179.5 ± 4.2 cm, 81.6 ± 8.6 kg). After familiarization, all participants performed two inertial progressive load tests on separated days to determine the flywheel load-velocity profile and its reliability. Each participant performed 5 set of 6 repetitions of the flywheel squat exercise with different inertial loads (0.047, 0.104, 0.161, 0.245, 0.321 kg m2) selected in a counterbalanced and randomized order for each testing day. Average MCLV and RPE for each load were compared.Results: The inter-session intraclass correlation coefficient (ICC) showed values above 0.9 in all the included outcomes (MCLV: ICC = 0.91; RPE: ICC = 0.93). A significant correlation (p < 0.01, R2 = 0.80) between inertial load and MCLV was found. Similarly, significant correlation models (p < 0.01) were observed between RPE and load (R2 = 0.87) and (R2 = 0.71) between RPE and MCLV.Conclusion: The control of MCLV during flywheel exercise can be proposed as a valid method to quantify load and to individualize the prescription of flywheel training. In addition, RPE responses have demonstrated significant correlations with load and velocity. Therefore, RPE has been proposed as a valid and reliable alternative to control flywheel training.

JGJesus Alarcon Gomez
Jesus Alarcon Gomez
Joaquín CalatayudJoaquín Calatayud
Joaquín Calatayud
Iván Chulvi-MedranoIván Chulvi-Medrano
Iván Chulvi-Medrano
FMFernando Martin-Rivera
Fernando Martin-Rivera
Cardiovascular complications are important causes of morbidity and mortality of Type 1 Diabetes Mellitus (T1DM) people. Regular exercise is strongly recommended to these patients due to its preventive action against this type of disease. However, a large percentage of patients with T1DM people present a sedentary behavior, mainly, because of the fear of a post-exercise hypoglycemia event and lack of time. High-intensity interval training (HIIT) is an efficient and safe methodology since it prevents hypoglycemia and does not require much time, which are the main barriers for this population to doing exercise and increasing physical conditioning. Nineteen sedentary adults (37 ± 6.5 years) with T1DM were randomly assigned to 6 weeks of either HIIT, 12 bouts first 2 weeks, 16 bouts in weeks 3 and 4, and 20 bouts in the last two weeks x 30-s intervals interspersed with 1-min rest periods, performed thrice weekly or to control group, which did not train. VO2max, body composition, heart rate variability (HRV), and fasting glucose were measured as cardiovascular risk factors. We suggest that the 6-week HIIT program used in the present study is safe since no severe hypoglycemia was reported and is an effective strategy in improving VO2max, body composition, HRV, and fasting glucose, which are important cardiovascular risk factors in T1DM people.