In recent years, as the number of reservoir embankments constructed has increased, embankment failures due to cracks in aging conduits have also increased. In this study, a crack in a conduit was modeled based on the current conduit design model, and the risk of internal erosion was analyzed using a large-scale model test and three-dimensional deformation–seepage analysis. The results show that when cracks existed in the conduit, soil erosion and cavitation occurred near the crack area, which made the conduit extremely vulnerable to internal erosion. Herein, a model is proposed that can reduce internal erosion by applying a layer of sand and geotextiles on the upper part of the conduit located close to the downstream slope. In the proposed model, only partial erosion occurred inside the conduit, and no cavitation appeared near the crack in the conduit. The results suggest that internal erosion can be suppressed when the water pressure acting intensively on the crack in the conduit is dispersed by the drainage layer. To validate these results, the pore water pressure, seepage line, and hydraulic gradient were investigated to confirm the erosion phenomenon and reinforcement effect.
Recently, heavy rains caused by climate change have resulted in dam failures due to overtopping. This study presents a design method aiming to prevent overtopping failures by applying gabion retaining walls at the dam crest. Simulations, experiments, and measurements were conducted to evaluate the effectiveness of this design. The design framework aims to establish a system in which gabion retaining walls prevent overtopping when water levels exceed the crest of the dam, efficiently draining seepage water into the dam body through vertical filters. Research findings indicate that implementing dam crest core and geomembrane design effectively prevents seepage and saturation of the downstream slope during overtopping events. Notably, the reservoir dam operates in a stable manner, as seepage water passing through the dam body is directed solely to the toe drain. Overall, this design approach suggests its potential as a practical solution by significantly reducing hazards resulting from heavy rainfall.
This study determines the effects of leakage attributed to conduit defects on the failure behavior on the downstream slope of a homogeneous reservoir. To analyze the failure mechanism, model experiments and a three-dimensional deformation–seepage analysis were conducted based on the failure shape, pore-water pressure, hydraulic gradient, and settlement, and the results were compared with the changes in the water storage capacity of the failed reservoir owing to conduit defects. The comparison showed that failure estimation based on settlement gauges and water storage capacity is limited in its ability to detect rapid changes compared with monitoring methods. An area of potential failure owing to internal erosion was formed at a location that is 1.4–2.4 times the conduit height on the downstream slope. The findings of this study can provide insights for determining the pre-reinforcement required to prevent or minimize reservoir failure due to the fact of leakage.
This study examines the effectiveness of parapets in preventing overtopping failures of small-scale homogeneous reservoir dams under seismic loads. In this study, a parapet covered the entire width of the dam crest and was designed to ensure its weight is transmitted to the dam crest. The test included four modes: initial mode, first seepage, seismic, and second seepage. The results show that without parapets the crack length and width expand significantly in the dam crest during the seismic mode, and the effect was large in the second seepage mode. The crack depth increased by 11.3–24 times during the seismic mode and expanded up to 73.3% of the dam height in the longitudinal direction along the axis of the crack formed in the dam crest during the second seepage mode. These findings suggest that the earthquake weakened the dam body, making it vulnerable to penetration. In contrast, the parapet structure effectively suppressed most of the tensile cracks by increasing the constraint force. Additionally, no crack expansion or tearing occurred during the second seepage mode post-earthquake, indicating improved seismic performance and suppression of seepage deformation.
Aging agricultural reservoirs are prone to increasing number of failures due to their overtopping. In this study, an L-type retaining wall was designed on a dam crest, and large-scale indoor model experiments were conducted to evaluate the seepage and deformation behavior as a function of buried depth and water-level variation. Experiments were conducted considering two buried depths, G.L -3 cm and G.L -7 cm from the dam crest, and three water levels, flood level, dam crest level, and overtopping level. Under both the buried depths, the saturated zone at the contact area between the dam crest and structure increased under the overtopping level condition, indicating potential risks. However, no seepage or deformation was observed, suggesting that the structure could effectively prevent failure. The pore water pressure exhibited similar behavior under both the buried depths, indicating that drainage through the filter was effective in dissipating the pressure. The horizontal and vertical displacements were significantly lower than the standard thresholds for the dam crest condition, suggesting that if the interface between the dam body and structure is properly managed, the results of this experiment may serve as a potential alternative solution to prevent overtopping-induced failures.