Macromolecular Crystallography is a powerful and valuable technique to assess protein structures. Samples are commonly cryogenically cooled to minimise radiation damage effects from the X-ray beam, but low temperatures hinder normal protein functions and this procedure can introduce structural artefacts. Previous experiments utilising acoustic levitation for beamline science have focused on Langevin horns which deliver significant power to the confined droplet and are complex to set up accurately. In this work, the low power, portable TinyLev acoustic levitation system is used in combination with an approach to dispense and contain droplets, free of physical sample support to aid protein crystallography experiments. This method facilitates efficient X-ray data acquisition in ambient conditions compatible with dynamic studies. Levitated samples remain free of interference from fixed sample mounts, receive negligible heating, do not suffer significant evaporation and since the system occupies a small volume, can be readily installed at other light sources.
Constructed wetlands are now accepted as an environmentally friendly means of wastewater treatment however, their effectiveness can be limited by excessive clogging of the pores within the gravel matrix, making this an important parameter to monitor. It has previously been shown that the clog state can be characterised using magnetic resonance (MR) relaxation parameters with permanent magnet based sensors. One challenge with taking MR measurements over a time scale on the order of years is that seasonal temperature fluctuations will alter both the way that the sensor operates as well as the relaxation times recorded. Without an understanding of how the sensor will behave under different temperature conditions, meaningful information about the clog state cannot be successfully extracted from a wetland. This work reports the effect of temperature on a permanent magnet based MR sensor to determine if the received signal intensity is significantly compromised as a result of large temperature changes, and whether meaningful relaxation data can be extracted over the temperature range of interest. To do this, the central magnetic field of the sensor was monitored as a function of temperature, showing an expected linear relationship. Signal intensity was measured over a range of temperatures (5 °C to 44 °C) for which deterioration at high and low temperatures compared to room temperature was observed. The sensor was still operable at the extremes of this range and the reason for the signal loss has been studied and explained. Spin-lattice relaxation time measurements using the sensor at different temperatures have also been taken on a water sample and seem to agree with literature values. Further to this, measurements have been taken in an operational wetland over the course of 203 days and have shown a linear dependence with temperature as would be expected. This work concluded that the sensor can perform the task of measuring the spin-lattice relaxation time over the required temperature range making it suitable for long-term application in constructed wetlands.
Magnetic resonance relaxometry, conducted by field cycling, has become an increasingly popular technique in recent years. In particular, it has the ability to monitor biomass transformation which is of particular interest to wastewater treatment. Traditional field cycling often uses expensive and large electromagnets. In this work we present a small, portable field cycling sensor which can detect changes in biomass in constructed wetland samples. Fast field cycling is a technique that uses a varying magnetic field applied to a sample, polarising it at a high field, allowing it time to develop at a lower field and then collecting the data at the same initial high field. This change in T1 can reveal interesting properties of the samples not achievable by traditional methods. A desktop magnetic resonance sensor that undertakes relaxometry measurements using field cycling has been developed using a combination of permanent magnets and electrical coils which has been used to test a range of samples. We demonstrate the effectiveness of this sensor by conducting measurements of T1 at different field strengths for wetland samples at different stages of biofilm growth.