fraser hill-casey

Dr. fraser hill-casey

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 March 2016 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Open access
PDF file
Nicola J. RogersNicola J. Rogers
Nicola J. Rogers
FHfraser hill-casey
fraser hill-casey
KSKarl F. Stupic
Karl F. Stupic
JSJoseph S. Six
Joseph S. Six
CLClémentine Lesbats
Clémentine Lesbats
TMThomas Meersmann
Thomas Meersmann
Significance: The high signal intensity associated with magnetic resonance of hyperpolarized129Xe has enabled countless applications ranging from materials science to biomedical MRI of the lung and brain. New modalities are constantly emerging; for example, hyperpolarized129Xe biosensors are of potential interest for molecular imaging of biomarker distribution in organs. Hyperpolarized83Kr shows promise as novel surface-sensitive contrast agent for pulmonary MRI but previous work was limited to excised lungs. This work reports a previously unexplored approach in the generation of hyperpolarized contrast agents that makes highly concentrated hyperpolarized83Kr available for the first time, to our knowledge. The results also provide the basis for on-demand flow production of highly concentrated hyperpolarized129Xe for in situ process monitoring and in vivo molecular imaging.

14 November 2019 in Molecules
Verified
Journal Article
Open access
PDF file
FHfraser hill-casey
fraser hill-casey
ASAminata Sakho
Aminata Sakho
AMAhmed Mohammed
Ahmed Mohammed
MRMatheus Rossetto
Matheus Rossetto
FAFadi Ahwal
Fadi Ahwal
MHMeghan Halse
Meghan Halse
Hyperpolarization methods, which increase the sensitivity of nuclear magnetic resonance (NMR) and magnetic resonance imaging (MRI), have the potential to expand the range of applications of these powerful analytical techniques and to enable the use of smaller and cheaper devices. The signal amplification by reversible exchange (SABRE) method is of particular interest because it is relatively low-cost, straight-forward to implement, produces high-levels of renewable signal enhancement, and can be interfaced with low-cost and portable NMR detectors. In this work, we demonstrate an in situ approach to SABRE hyperpolarization that can be achieved using a simple, commercially-available Earth’s field NMR detector to provide 1H polarization levels of up to 3.3%. This corresponds to a signal enhancement over the Earth’s magnetic field by a factor of ε > 2 × 108. The key benefit of our approach is that it can be used to directly probe the polarization transfer process at the heart of the SABRE technique. In particular, we demonstrate the use of in situ hyperpolarization to observe the activation of the SABRE catalyst, the build-up of signal in the polarization transfer field (PTF), the dependence of the hyperpolarization level on the strength of the PTF, and the rate of decay of the hyperpolarization in the ultra-low-field regime.

1 April 2016 in Sensors and Actuators A: Physical
Verified
Journal Article
Open access
Theodore Hughes-RileyTheodore Hughes-Riley
Theodore Hughes-Riley
EDElizabeth Dye
Elizabeth Dye
DADario Ortega Anderez
Dario Ortega Anderez
FHfraser hill-casey
fraser hill-casey
MNMichael I. Newton
Michael I. Newton
RMRobert H. Morris
Robert H. Morris
Constructed wetlands are now accepted as an environmentally friendly means of wastewater treatment however, their effectiveness can be limited by excessive clogging of the pores within the gravel matrix, making this an important parameter to monitor. It has previously been shown that the clog state can be characterised using magnetic resonance (MR) relaxation parameters with permanent magnet based sensors. One challenge with taking MR measurements over a time scale on the order of years is that seasonal temperature fluctuations will alter both the way that the sensor operates as well as the relaxation times recorded. Without an understanding of how the sensor will behave under different temperature conditions, meaningful information about the clog state cannot be successfully extracted from a wetland. This work reports the effect of temperature on a permanent magnet based MR sensor to determine if the received signal intensity is significantly compromised as a result of large temperature changes, and whether meaningful relaxation data can be extracted over the temperature range of interest. To do this, the central magnetic field of the sensor was monitored as a function of temperature, showing an expected linear relationship. Signal intensity was measured over a range of temperatures (5 °C to 44 °C) for which deterioration at high and low temperatures compared to room temperature was observed. The sensor was still operable at the extremes of this range and the reason for the signal loss has been studied and explained. Spin-lattice relaxation time measurements using the sensor at different temperatures have also been taken on a water sample and seem to agree with literature values. Further to this, measurements have been taken in an operational wetland over the course of 203 days and have shown a linear dependence with temperature as would be expected. This work concluded that the sensor can perform the task of measuring the spin-lattice relaxation time over the required temperature range making it suitable for long-term application in constructed wetlands.